Historic Districts Review Board Meeting — Tue, Nov 10, 2026 · 9K. 2026-013402-HDRB. 224 E Palace Ave, Downtown and Eastside Historic District. Significant. Dimitrov Design Studio LLC, Tiho Dimitrov, agent for Drury Southwest Santa Fe Inc., owner, proposes to remove the ADA ramp, basement access exterior steps, walls, and metal railings, and replace pipe guardrails. Exceptions are requested to 14-4.6(E)(4)(II) for alterations to primary facades. (Lani McCulley)
October 29, 2026 Lani McCulley, Historic Senior Planner City of Santa Fe – Historic Preservaon Division / Land Use Department 200 Lincoln Ave, 1st Floor Santa Fe, NM 87501 RE: Request for HDRB hearing/amendment of exisng HDRB approval – Case #2025-010093HDRB Dear Ms. McCulley, I submit this request for an HDRB hearing, along with the a:ached documents (drawings and excepon criteria) for the Drury Plaza Hotel/Marian Hall Renovaon project located at 224 E. Palace Avenue, exisng case# 2025-010093HDRB, on behalf of the property owner, Drury Santa Fe, LLC. As previously discussed, an applicaon form is not included in this submi:al, as this is a request to amend approval of an exisng case. On May 13, 2025, The Historic Design Review Board reviewed and approved proposed renovaon and adapve reuse of the building known as Marian Hall, a three-story CraBsman Style building with a Significant status in the Downtown & Eastside Historic District. The Board acted unanimously to approve the project as presented without any condions. Since that approval, the project has completed its construcon documentaon phase and has been reviewed by the Building/Permit Department, and a building permit has been issued, and the project is now in construcon. During the design development and construcon documentaon phases, the owner idenfied a few design and funcon issues, which were not addressed in the original proposal reviewed and approved by the Board. We would like to present these items to the Board and request their approval. The proposed alteraons are: 1. Demolion of exisng non-original (non-historic) concrete stair from grade to basement level, and its associated walls and railings a. This stair is not original to the building, added in the 1950’s. It is not visible from the public right of way, as it is a stair that leads to a basement level below grade. The only visible por on of it is the guardrail at grade, which is also from the 50’s, a 2” metal pipe railing. The stair was abandoned some years ago, and there is no landing or access to it at grade. Its removal will not impact any historic material or affect the integrity of the historic façade. See a&ached photos of exis ng stair condi ons. 2. Replacement of exisng non-original 2” metal pipe guardrail/railing at East Façade with new metal guardrail1114 Hickox St., Suite A Santa Fe, NM 87505 505.820.1555 224 E. Palace Avenue (Marian Hall) HDRB Review for Proposed Work Case #2025-010093HDRB Page 2 of 2 a. The exis ng guardrail/railing is not original to the building, added in the 50’s, and has an industrial appearance, incongruous with the east façade’s Cra*sman style architecture. Since this railing is detached from the façade, it will not impact any historic materials or affect the historic integrity of the building. See a&ached photos of exis ng condi ons and historic photo from early 1950’s. 3. Proposed new metal guardrail at east façade at historic stair to basement a. This proposed guardrail will replace the non-historic 2” metal pipe guardrail which was approved for demoli on by the Board in 2025. 4. Proposed new metal privacy railings at west and south veranda access points. a. The proposed metal privacy railings are needed for security and privacy of the ground floor hotel rooms. There are four exis ng concrete stairs for accessing the veranda at the south and west facades that lead right up to hotel guest room windows, compromising guest privacy and security. The proposed privacy railings will be only visible from the interior side of the site and will be anchored in a manner that allows for their removal without affec ng historic material. New work will be differen ated from historic and not mimic it. We acknowledge Marian Hall’s significance to the Downtown & Eastside Historic District and to the city’s history, and our proposed soluons take that into account. We have followed the Department of the Interior’s Guidelines for Rehabilitaon and none of the proposed alteraons will destroy any historic materials or character-defining features. We are requesng two excepons to the Design Standards, due to the building’s historic status. A:ached are Excepons Criteria Responses(Exhibit A), drawings of the proposed work (Exhibit B), and reference photos of the exisng condions (Exhibit C). Thank you for assisng us with this case. If you need addional informaon, let me know. Tiho Dimitrov, AIA, Project Manager Woven Architecture, LLCmitrov, Project 224 E. Palace Avenue – Marian Hall Rehabilitation & Adaptive Reuse Exception Criteria October 29, 2026 Design Standards & Signage Exceptions The requested exceptions to Design Standards are listed below: 1) 14-5.2(D)(1)(a) demolition of existing concrete stair from grade to basement level at southeast corner. 2) 14-5.2(D)(5)(b) addition of metal privacy railing and guardrails at west and south Portals and east elevation (primary facades) I.) Exception will not damage the character of the district. 1) Demolition of existing concrete stair from grade to basement level at southeast corner The demolition of the existing non-original stairs that lead from the basement to existing grade will not damage the character of the district because they are below grade and therefore not visible to the public; they were built in the 50’s and are not original to the building; are made of poured-in-place concrete and have no character-defining features and were built solely for functional purposes of the basement; the character of the district is defined by visible building features, building styles, and massing, not by building features not visible from the public right of way. 2) Addition of metal privacy railing & guardrails at west and south portals, and at east façade, along existing lightwell and stair (primary facades). This exception to allow addition of new railings to a primary façade will not damage the character of the district because the proposed changes to the façade will not alter the overall character of the building, its style and detailing, or its impact on the district. The original building design and facades featured wood railings along the portals. These railings were removed sometime in the 1940s-50s. The existing condition of the east façade features a non-historic metal pipe railing at the stair and light well. None of the proposed elements are out of style or character for this district and their addition would fit in and be of better aesthetic quality than the existing pipe railing. The proposed design of these railings & guardrails is similar to the existing wrought iron fence along the north façade of the building but does not imitate it. Therefore, it will blend within the existing context, without creating a false sense of history. Also, the railings at the south and west porches can be installed in a manner that allows for their removal at a later time, without damaging the structure or historic materials of the building. II.) Exception required to prevent a hardship to the applicant or an injury to the public welfare. 1) Demolition of existing concrete stair from grade to basement level at southeast corner Demolition of existing concrete stair from grade to basement level stair at southeast corner – this stair has been abandoned as the building function has changed over the years. Leaving it as-is creates a hardship to the applicant and a possible injury to the public welfare for these reasons – the stair leads to a dead-end space below grade, and is often used by transient/unhoused people squatting, using the space as shelter; the stair tends to become frozen and icy in cold months, posing a danger of injury for anyone who may decide to walk on it; the steps do not meet current building code requirements; The stair has been abandoned and without maintenance, it will fall in further disrepair.EXHIBIT A 224 E. Palace Avenue – Marian Hall Rehabilitation & Adaptive Reuse Exception Criteria October 29, 2026 2) Addition of metal privacy railing and guardrails at west and south portals and at east elevation, along light well and existing stair (primary façade) An exception to the Design Standards would prevent the following hardship to the applicant and injury to public welfare – The existing pipe railing/guardrail at the east- elevation light well and stair does not meet the minimum 4” spacing building code requirement, posing a risk to public welfare; the existing stairs that lead to the porches at the south and west facades offer unobstructed access to the porches, which compromises the privacy and security of hotel guests, therefore posing a hardship for the applicant. There is no alternative way to limit access to the porch area and offer hotel guests privacy and security or to close off this private area from being used/accessed by public, without granting this exception. III.) Exception will strengthen the unique heterogeneous character of the City by providing a full range of design options to ensure that residents can continue to reside within the Historic Districts. 1) Demolition of existing concrete stair from grade to basement level at southeast corner Removing the abandoned and unsafe concrete stair, which serves no purpose and is not original to the building, will improve the overall experience of this building, its appearance, and have a positive impact on the surroundings. By removing the dead-end landing, which is below grade, we alleviate the problem of its use by unhoused, either for shelter or in lieu of a toilet. We believe that cleaning up this building’s surroundings, including the removal of this non-original stair, will improve the residents’ experience of the Historic Districts and strengthen the character of the City. 2) Addition of metal privacy railing & guardrails at west and south portals, and at east façade, along existing lightwell and stair (primary facades). Similar to above, replacing the unsightly 2” metal-pipe railing with a more aesthetically pleasing railing and guardrail along the east façade will improve the residents’ experience of the City and the streetscape. It will allow us to remove an industrial-looking element, which is out of place in this location, and replace it with a more congruent and pleasing one, helping to strengthen this building’s historic integrity and significance. As for the proposed new privacy railing & guardrails at the south and west facades, we believe their addition to the respective facades will strengthen the City’s unique character by allowing this building to adapt to a new use and have a successful use as a hotel, facing the most visited park in the city – Cathedral Park, without compromising the Owner’s objectives and the hotel guests’ experience. Allowing this exception does not affect in any way the residents’ ability to reside in the Historic Districts. It simply allows for some privacy and access control features to be installed at this private building, without a negative impact on residents. These railings & guardrails can be installed without removing any historic material and can be removed at a later time without affecting the existing historic facades. Marian Hall Photographs, Exhibit C 1 Existing ADA ramp and walls - South Façade Existign ADA ramp and walls - West Façade Marian Hall Photographs, Exhibit C 2 East Facade - current condition East Facade - historic photo, 1951 Marian Hall Photographs, Exhibit C 3 Stair to Basement - existing condition East Facade - historic photo, 1951 Marian Hall Photographs, Exhibit C 4 Existing Iron Fence along north facade - Palace Avenue FH VAN UPDN ONLY HOTEL (EXIST. 5-STORY BUILDING) 828 PASEO DE PERALTA S17°45'50"W 30.10' S72°40'55"E 66.95' S16°37'18"W 81.02' N07°39'16"W 7.24' N19°27'58"E 36.95' S71°47'05"E 23.64' S67°14'19"E47.65' S58°15'36"E 97.40' S65°45'36"E 143.71' S67°11'48"E 36.51' S69°36'51"E 245.34' S73°52'20"E 558.55' S05°08'48"W 392.48' _=79°00'52" L=34.48' R=25.00' CHORD=S34°21'34"E 31.81' S17°19'31"W 54.79' 20' EMERGENCY VEHICLE ROUTE 10' SETBACK 10' 5' BUILDING SETBACK 10' EXISTING BUILDING SETBACK 5' 18 8 10 10 15 7 ST. FRANCIS CATHEDRAL PARK CATHEDRAL (OPEN SPACE) DRIVEWAY DRIVEWAY ALLEY PALACE AVENUE PASEO DE PERALTA SERVICE ACCESS RD. PROMENADE EXISTING PARKING GARAGE (OPEN SPACE) HOTEL DROPOFF AREA MEETING 20' 27' PORTAL PORTAL LOADING & SOLID WASTE 10' 10' LINE OF PORTAL BLDG. SETBACK 838 PASEO DE PERALTA EXIST. EXIST. BUILDING RESTAURANTPATIO DINING ROOM HOTEL GARDENHOTEL GARDEN 3-STORY BLDG EXISTING VERANDA EXISTING VERANDA EXISTING PARKING PROMENADE ARCHDIOCESE 24' RAMP TO LOWER LEVEL PROMENADE EXISTING (HOTEL USE) (IN-HOTEL) LA POSADA EXISTING MEETING ROOMS (HOTEL USE) 224 E. PALACE AVENUE EXISTING 32.05 (EXISTING) (EXISTING) 07 EXISTING NON-ORIGINAL RAILING TO BE REMOVED AND REPLACED WITH NEW EXISTING NON-ORIGINAL STAIR AND RAILING TO BE DEMOLISHED DRAWN BY All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. Sheet No. SHEET NO. SHEETSOF Sheet Name CHECKED BY FILE NAME PROJECT NO ISSUED A B C D 1 2 3 4 5 1114 Hickox Street, Ste A, Santa Fe, NM 87505 Phone: 505.820.1555 Woven Architecture Autodesk Docs://Marian Hall/Marian Hall - 2025.rvt 10/2/2026 12:54:14 PM HA001 SITE PLAN TD TD, BJF MARIAN HALL RENOVATION 224 E. PALACE AVENUE SANTA FE, NM 87501 25011 (58-1-037) 10/02/26 MARK DATE DESCRIPTION 1" = 30'-0"HA001 1 EXISTING SITE PLAN (FOR REFERENCE ONLY) NORTH 15' 30' 60'0 2"0 1" = 30'-0" NO CHANGES TO SITE PLAN ARE PROPOSED. THE ONLY WORK PROPOSED IS: • REMOVAL OF EXISITNG NON-HISTORIC ADA RAMP AT WEST/SOUTH FACADES, • DEMOLITION OF NON-ORIGINAL STAIR FROM GRADE TO BASEMENT • REPLACEMENT OF EXISTING NON-ORIGINAL RAILING AT EAST FACADE WITH NEW • PROPOSED IRON PRIVACY RAILING AT WEST AND SOUTH FACADESEXHIBIT B DN DEMOLISH EXISTING ABANDONED CONCRETE STAIR TO BASEMENT AND EXISTING NON- HISTORIC METAL PIPE GUARDRAIL. THIS STAIR IS INACTIVE AND IS NOT ORIGINAL TO THE BUILDING. IT WAS CONSTRUCTRED IN THE 1950'S ITS REMOVAL WILL NOT CHANGE THE FACADE APPEARANCE, AS IT IS BELOW NATURAL GRADE. DEMOLISH EXISTING NON-HISTORIC METAL PIPE GUARDRAIL AND REPLACE WITH NEW. EXISTING RAILING IS NOT ORIGINAL TO THE BUILDING, ADDED IN THE 1950's, HAS INDUSTRIAL APPEARANCE, NOT MATCHING THE CRAFTSMAN STYLE ARCHITECTURE DEMOLISH EXISTING NON-HISTORIC METAL PIPE GUARDRAIL (ALREADY APPROVED BY HDRB) LOBBY GUEST RM. GUEST RM.GUEST RM. GUEST RM.GUEST RM. GUEST RM. GUEST RM.GUEST RM.GUEST RM. GUEST RM. GUEST RM. GUEST RM. GUEST RM. CORRIDOR VERANDA VERANDA EXISTING WALL TO REMAIN EXISTING WALL/MATERIAL TO BE DEMOLISHED DRAWN BY All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. Sheet No. SHEET NO. SHEETSOF Sheet Name CHECKED BY FILE NAME PROJECT NO ISSUED A B C D 1 2 3 4 5 1114 Hickox Street, Ste A, Santa Fe, NM 87505 Phone: 505.820.1555 Woven Architecture Autodesk Docs://Marian Hall/Marian Hall - 2025.rvt 10/29/2026 7:52:04 PM HA101 EXISTING & DEMOLITION PLAN - GROUND LEVEL Author Checker MARIAN HALL RENOVATION 224 E. PALACE AVENUE SANTA FE, NM 87501 25011 (58-1-037) 02/24/2026 1/8" = 1'-0"HA101 1 EXISTING AND DEMOLITION FLOOR PLAN - GROUND LEVEL 4' 8' 16'0 2"0 1/8" = 1'-0" NORTH MARK DATE DESCRIPTION LEGEND DN PROPOSED 36" HIGH DECORATIVE METAL RAILING FOR GUEST ROOM PRIVACY PROPOSED 36" HIGH DECORATIVE METAL RAILING FOR GUEST ROOM PRIVACY PROPOSED 36" HIGH DECORATIVE METAL RAILING FOR GUEST ROOM PRIVACY PROPOSED 36" HIGH DECORATIVE METAL RAILING FOR GUEST ROOM PRIVACY PROPOSED 42" HIGH DECORATIVE METAL GUARDRAIL/RAILING AT EXISTING LIGHTWELL PROPOSED 42" HIGH DECORATIVE METAL RAILING FOR GUEST ROOM PRIVACY IN PLACE OF EXISTING 2" DIA. METAL PIPE RAILING 1 HA202 ____ 1 HA201 ____ 1 HA203 ____ PROPOSED 42" HIGH DECORATIVE METAL GUARDRAIL/RAILING AT EXISTING STAIR 60" HIGH DECORATIVE METAL PRIVACY GUARDRAIL DRAWN BY All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. Sheet No. SHEET NO. SHEETSOF Sheet Name CHECKED BY FILE NAME PROJECT NO ISSUED A B C D 1 2 3 4 5 1114 Hickox Street, Ste A, Santa Fe, NM 87505 Phone: 505.820.1555 Woven Architecture Autodesk Docs://Marian Hall/Marian Hall - 2025.rvt 10/29/2026 7:52:05 PM HA102 PROPOSED FLOOR PLAN - GROUND LEVEL TD TD MARIAN HALL RENOVATION 224 E. PALACE AVENUE SANTA FE, NM 87501 25011 (58-1-037) 02/24/2026 MARK DATE DESCRIPTION 1/8" = 1'-0"HA102 1 PROPOSED FLOOR PLAN - GROUND LEVEL 4' 8' 16'0 2"0 1/8" = 1'-0" NORTH FIRST FLOOR 0' - 0" 2ND FLOOR 13' - 4" 3RD FLOOR 24' - 7" BASEMENT -8' - 10" OUTLINE OF EXISTING HOTEL BUILDING PROPOSED 36" HIGH DECORATIVE METAL RAILING FOR GUEST ROOM PRIVACY PROPOSED 36" HIGH DECORATIVE METAL RAILING FOR GUEST ROOM PRIVACY FIRST FLOOR 0' - 0" 2ND FLOOR 13' - 4" 3RD FLOOR 24' - 7" BASEMENT -8' - 10" OUTLINE OF EXISTING HOTEL BUILDING DEMOLISH EXISTING NON-HISTORIC METAL PIPE GUARDRAIL/RAILING AND CONCRETE STAIR BELOW GRADE DRAWN BY All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. Sheet No. SHEET NO. SHEETSOF Sheet Name CHECKED BY FILE NAME PROJECT NO ISSUED A B C D 1 2 3 4 5 1114 Hickox Street, Ste A, Santa Fe, NM 87505 Phone: 505.820.1555 Woven Architecture Autodesk Docs://Marian Hall/Marian Hall - 2025.rvt 10/29/2026 7:52:07 PM HA201 EXTERIOR ELEVATIONS Author Checker MARIAN HALL RENOVATION 224 E. PALACE AVENUE SANTA FE, NM 87501 25011 (58-1-037) 09/30/26 MARK DATE DESCRIPTION 1/8" = 1'-0"HA201 1 SOUTH ELEVATION - PROPOSED 1/8" = 1'-0"HA201 2 SOUTH ELEVATION - AS APPROVED BY HDRB (EXISTING) 4' 8' 16'0 2"0 1/8" = 1'-0" 4' 8' 16'0 2"0 1/8" = 1'-0" PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 FIRST FLOOR 0' - 0" 2ND FLOOR 13' - 4" 3RD FLOOR 24' - 7" BASEMENT -8' - 10" 1ST FLOOR 0' - 0" 2ND FLOOR 13' - 4" 3RD FLOOR 24' - 7" BASEMENT -8' - 10" ROOF 33' - 8" PROPOSED 36" HIGH DECORATIVE METAL RAILING FOR GUEST ROOM PRIVACY HA202 3 FIRST FLOOR 0' - 0" 2ND FLOOR 13' - 4" 3RD FLOOR 24' - 7" BASEMENT -8' - 10" 1ST FLOOR 0' - 0" 2ND FLOOR 13' - 4" 3RD FLOOR 24' - 7" BASEMENT -8' - 10" ROOF 33' - 8" 3' - 0" 4" EQ EQ IRON QUAD-FLARE FINIAL FENCE TOP, TYPICAL 1/2" SQUARE IRON FENCE PICKETS, TYP. DRAWN BY All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. Sheet No. SHEET NO. SHEETSOF Sheet Name CHECKED BY FILE NAME PROJECT NO ISSUED A B C D 1 2 3 4 5 1114 Hickox Street, Ste A, Santa Fe, NM 87505 Phone: 505.820.1555 Woven Architecture Autodesk Docs://Marian Hall/Marian Hall - 2025.rvt 10/29/2026 7:52:09 PM HA202 EXTERIOR ELEVATIONS Author Checker MARIAN HALL RENOVATION 224 E. PALACE AVENUE SANTA FE, NM 87501 25011 (58-1-037) 09/30/26 MARK DATE DESCRIPTION 1/8" = 1'-0"HA202 1 WEST ELEVATION 1/8" = 1'-0"HA202 2 WEST ELEVATION - AS APPROVED BY HDRB (EXISTING) 4' 8' 16'0 2"0 1/8" = 1'-0" 4' 8' 16'0 2"0 1/8" = 1'-0" 1 1/2" = 1'-0"HA202 3 PROPOSED PRIVACY FENCE 1.3'0 4" 8" 2"0 1 1/2" = 1'-0" PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999PRO PRIETARYDESIG NO FALLO YCASTING CCOPYRIG HT1999 FIRST FLOOR 0' - 0" 2ND FLOOR 13' - 4" 3RD FLOOR 24' - 7" BASEMENT -8' - 10" PROPOSED 42" HIGH DECORATIVE METAL RAILING IN PLACE OF EXISTING NON-HISTORIC METAL PIPE RAILING PROPOSED 42" HIGH DECORATIVE METAL RAILING IN PLACE OF EXISTING NON-HISTORIC METAL PIPE RAILING FIRST FLOOR 0' - 0" 2ND FLOOR 13' - 4" 3RD FLOOR 24' - 7" BASEMENT -8' - 10" EXISTING METAL PIPE GUARDRAIL TO BE DEMOLISHED (APPROVED BY HDRB) DEMOLISH EXISTING NON-HISTORIC METAL PIPE GUARDRAIL AND REPLACE WITH NEW. EXISTING RAILING IS NOT ORIGINAL TO THE BUILDING, ADDED IN THE 1950's, HAS INDUSTRIAL APPEARANCE, NOT MATCHING THE CRAFTSMAN STYLE ARCHITECTURE DEMOLISH EXISTING ABANDONED CONCRETE STAIR TO BASEMENT AND EXISTING NON-HISTORIC METAL PIPE GUARDRAIL. THIS STAIR IS INACTIVE AND IS NOT ORIGINAL TO THE BUILDING. IT WAS CONSTRUCTRED IN THE 1950'S ITS REMOVAL WILL NOT CHANGE THE FACADE APPEARANCE, AS IT IS BELOW NATURAL GRADE. 3' - 6" 4" EQ EQ DRAWN BY All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. Sheet No. SHEET NO. SHEETSOF Sheet Name CHECKED BY FILE NAME PROJECT NO ISSUED A B C D 1 2 3 4 5 1114 Hickox Street, Ste A, Santa Fe, NM 87505 Phone: 505.820.1555 Woven Architecture Autodesk Docs://Marian Hall/Marian Hall - 2025.rvt 10/2/2026 12:28:45 PM HA203 EXTERIOR ELEVATIONS TD BJF, TD MARIAN HALL RENOVATION 224 E. PALACE AVENUE SANTA FE, NM 87501 25011 (58-1-037) 09/30/26 MARK DATE DESCRIPTION 1/8" = 1'-0"HA203 1 EAST ELEVATION - PROPOSED 1/8" = 1'-0"HA203 2 EAST ELEVATION - AS APPROVED BY HDRB (EXISTING) EXISTING CONDITION AT STAIR TO BASEMENT 4' 8' 16'0 2"0 1/8" = 1'-0" 4' 8' 16'0 2"0 1/8" = 1'-0" 1 1/2" = 1'-0"HA203 3 PROPOSED IRON RAILING DETAIL 1.3'0 4" 8" 2"0 1 1/2" = 1'-0" EXISTING IRON FENCE AT NORTH FACADE FIRST FLOOR 0' - 0" 2ND FLOOR 13' - 4" 3RD FLOOR 24' - 7" BASEMENT -8' - 10" 49' - 7 9/16"± OUTLINE OF EXISTING HOTEL BUILDING Y DRAWN BY All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. Sheet No. SHEET NO. SHEETSOF Sheet Name CHECKED BY FILE NAME PROJECT NO ISSUED A B C D 1 2 3 4 5 1114 Hickox Street, Ste A, Santa Fe, NM 87505 Phone: 505.820.1555 Woven Architecture Autodesk Docs://Marian Hall/Marian Hall - 2025.rvt 10/2/2026 12:28:46 PM HA204 EXTERIOR ELEVATIONS TD BJF, TD MARIAN HALL RENOVATION 224 E. PALACE AVENUE SANTA FE, NM 87501 25011 (58-1-037) 09/30/26 MARK DATE DESCRIPTION 1/8" = 1'-0"HA204 1 NORTH ELEVATION - AS APPROVED BY HDRB (EXISTING) NO CHANGES PROPOSED TO NORTH FACADE, INCLUDED ONLY FOR REFERENCE 4' 8' 16'0 2"0 1/8" = 1'-0"