Regular Governing Body Meeting - Last Wednesday — Wed, Oct 28, 2026 · 10A. Request for Acceptance of City Attorney's Office Recommendation to Deny Appeal of Planning Commission's Approval of Conditional Use Permit for 1802 Cerrillos Road, Appeal #2026-012949-APPL, Land Use Case #2025-11756. (Natalie Cauley, Assistant City Attorney, nscauley@santafenm.gov) Committee Review: Governing Body: 10/28/2026
1
MEMORANDUM
To: Members of the Governing Body
From: Natalie Cauley, Assistant City Attorney
Via: Marcos Martínez, City Attorney
Re: Appeal #2026-012949-APPL; Recommendation on Conformity of Appeal by Forrest
Thomas, Thomas Trust Holdings, LLC of the Planning Commission’s approval of a
Conditional Use Permit in Case #2026-11756 to allow a self-storage facility at 1802
Cerrillos Road, 1750 Cerrillos Road, 1361 Fourth Street, and 3 Berry Avenue
Date: October 21, 2026; for the October 28, 2026 Meeting of the Governing Body
______________________________________________________________________________
I. Introduction
The Planning Commission approved an application for a Conditional Use Permit for a
storage facility at 1802 Cerrillos Road, 1750 Cerrillos Road, 1361 Fourth Street, and 3 Berry
Avenue (the “Property”). Forrest Thomas, with Thomas Trust Holdings, LLC (the “Appellant”)
filed an appeal of the approval (the “Appeal”). [Attachment A: Verified Appeal Petition] As
contemplated in City Code, the Land Use Director reviewed the Appeal and, finding it did not
comply with the requirements for appeal, referred it to the City Attorney’s Office for review.
[Attachment B: Land Use Director Appeal Petition Conformity Review] The City Attorney’s
Office agrees that the Appeal fails to conform to the legal requirements for an appeal set forth in
Santa Fe City Code. The City Attorney’s Office therefore recommends that the Governing
Body deny the Appeal without a public hearing.
II. Background
The present recommendation concerns an application for a Conditional Use Permit
submitted by Amatren LLC (the “Applicant”) for the subject Property, the former Empire Builders
site (Land Use Case #2025-11756). The Property is located in a C-2 zone. The application sought
a Permit to develop an indoor self-storage facility containing climate-controlled storage and
community offices, creative office suites (mini-storage units), and a community dog park on 2.72
2
acres. Conditional use approval is required for self-storage facilities in a C-2 zone. See SFCC 1987,
Section 14-5.2 Table 5-1 Summary Table of Allowed Uses. The Conditional Use Permit was
approved by the Planning Commission after a public hearing on June 4, 2026.
The Applicant simultaneously applied for approval of a Development Plan for the Property
(Case #2025-11753). The Development Plan was also approved by the Planning Commission on
June 4, 2026.
On August 4, 2026, the Appellant Forrest Thomas contacted Land Use Director Heather
Lamboy to inquire about the deadline for filing appeals of the Conditional Use Permit and
Development Plan. The Appellant had received a mailed notice of the June 4 public hearing as he
has an adjoining property. On August 7, Director Lamboy responded that, “after consultation with
the City Attorney’s Office, a 30-day deadline would apply to both appeals.” [Attachment B at 2]
(As outlined below, this advice was mistaken but did not materially alter the Appellant’s position
given the filing deadline for the Conditional Use Permit had already passed.)
On August 10, 2026, the Appellant filed appeals of both the Conditional Use Permit
(Appeal #2026-012949-APPL) and the Development Plan (Appeal #2026-012950-APPL). On
October 1, 2026, the Land Use Director issued a conformity review concluding that the Appeal of
the Conditional Use Permit was procedurally defective because it was filed outside the 15-day
appeal window required by City Code. [Attachment B] The Director forwarded her conclusion to
the City Attorney’s Office, resulting in the present written recommendation.
At the same time, the Land Use Director issued a conformity review concluding that the
appeal of the Development Plan may go forward, given the 30-day appeal window applicable to
such matters. The Development Plan appeal is scheduled to be heard by the Governing Body at a
special hearing on November 18, 2026.
III. Procedural Posture
This recommendation comes before the Governing Body pursuant to City Code. SFCC
1987 Section 14-2.1(B)(5)(IV)(k) provides that, following the filing of a land use appeal, the Land
Use Director “shall promptly review all appeals for conformity with the requirements” of code.
The following procedures are then specified:
If the Planning and Land Use Director determines that an appeal does not conform to
the requirements, the Planning and Land Use Director shall refer the matter to the City
attorney for review.
1. If the City Attorney concurs with the Planning and Land Use Director’s
determination, the City Attorney’s written recommendation shall be forwarded
to the Governing Body for discussion. The Governing Body may accept the
City Attorney’s written recommendation and the decision is final and may be
appealed to district court. If the Governing Body does not accept the City
Attorney’s recommendation, the appeal shall be heard as set forth in Chapter
14.
2. If the City Attorney does not concur with the Planning and Land Use Director’s
determination, the appeal shall be heard as set forth in Chapter 14.
3
SFCC 1987 Section 14-2.1(B)(5)(IV)(k).
The process described grants the Governing Body the discretion to dismiss an Appeal
without a hearing if it agrees with the City Attorney’s recommendation. In the present case, as
noted, the Land Use Director issued a conformity review and determined the Appeal did not
conform to code requirements. This review was forwarded to the City Attorney’s Office, which
concurs with that review and now recommends the Governing Body deny the appeal without a
public hearing for the reasons that follow.
IV. Legal Basis to Dismiss Appeal
The Appellant failed to meet the 15-day appeal deadline outlined in City Code for an appeal
of a Conditional Use Permit. A mistaken communication from City Staff does not excuse this
failure and relevant dates indicate the Appellant did not materially rely on this communication to
his detriment.
A. Conditional Use Permits must be appealed within 15 days of the final action
Appeals of decisions by City land use boards, including the Planning Commission, are
controlled by SFCC 1987, Section 14-2.1(B)(5)(IV). A final action that may be appealed includes
a “[d]ecision of a land use board after a public hearing.” SFCC 1987, Section 14-
2.1(B)(5)(IV)(a)(1)(i). The Planning Commission’s approval of the Applicant’s Conditional Use
Permit therefore qualifies as a final action subject to appeal.
The date of the final action determines when the appeal window begins to run. The Code
specifies the date of a final action by a land use board is determined as follows:
The date the decision-making body adopts a written decision containing findings of
fact and conclusions of law; provided that if the decision-making body has not adopted
findings of fact and conclusion of law within 35 days of the date the vote deciding the
matter was taken, then the date of final action shall be deemed to be the 35th day after
the date the vote deciding the matter was taken.
SFCC 1987, Section 14-2.1(B)(5)(IV)(d)(2).
In this case, the Planning Commission adopted the Findings of Fact and Conclusions of
Law on September 3, 2026. [Attachment C] This was more than 35 days after the June 4, 2026
hearing where the Commission took its vote approving the Permit. As a result, the date of the
Commission’s final action on the Permit is calculated to be 35 days after the Commission’s vote
at the public hearing — that is, July 9, 2026.
The deadline to file an appeal is calculated from the date of the final action. Subsection e
of the appeal procedures in City Code provides the following deadlines:
e. Appellants shall file an appeal as follows:
1. Final actions by land use boards on subdivision plats, master plans, or
development plans: within 30 days.
4
2. Final action by the Planning and Land Use Director on application for a final
plat for resubdivision or summary subdivision: within 30 days.
3. All other final actions: within 15 days.
The present Appeal does not involve subdivision plats, re-subdivisions, master or development
plans. Thus, the deadline to file an appeal was 15 days after the final action of July 9, 2026. This
was July 24, 2026. Instead, the appeal of Case #2025-11756 was filed on August 10, 2026.
The timelines and the procedures articulated in the City Code are not just suggestions or
recommendations. “Rules and regulations adopted by city ordinance have the force of law.”
Apodaca v. AAA Gas Co., 2003-NMCA-085, ¶ 48, 134 N.M. 77, 95. “Having the force of law,
municipal rules and regulations impose a standard and a duty to comply with that standard.” Id.
Even if the Appellant was not aware of the 15-day appeal deadline, a person’s “[n]oncompliance
is not excused by ignorance of the standard.” Id.
B. Mistaken advice from City Staff does not warrant granting the Appeal.
As detailed above, City staff mistakenly advised the Appellant that the appeal of the
Conditional Use Permit was subject to the same 30-day appeal deadline that applied to the separate,
parallel appeal of the Development Plan for the same Property. In the Appeal, the Appellant writes,
The Planning Commission voted to approve the applications June 4, 2026. The City
later advised that July 9 was the deemed final-action date. Following consultation with
the City Attorney’s Office, the Planning and Land Use Director advised Appellants in
writing that the 30-day appeal deadline applies to both Case 2025-11753 and Case
2025-11756. Under current SFCC Section 14-9.1(D), the Saturday, August 8 deadline
moved to Monday, August 10. This appeal is tendered August 10 and is timely under
the City’s written determination.
[Attachment A at 3]
The incorrect advice tendered by City staff does not change the outcome here. The
Appellant had access to the code requirements and could align his behavior to comply with those
requirements. Most importantly, the Appellant did not seek feedback from the Land Use Director
about the deadline for filing an appeal until August 4, 2026, ten days after the 15-day appeal
window had closed. In other words, he did not rely on the City’s advice to his detriment. He had
already missed the deadline for appealing the Conditional Use Permit at the time he received the
incorrect advice and thus the advice did not materially change his position. After realizing the
mistake, the Land Use Director offered the Appellant to voluntarily withdraw the appeal of the
Conditional Use Permit and be reimbursed the appeal fee. The Appellant declined.
V. Conclusion
The City Attorney’s Office recommends that the Governing Body reject Appeal #2026-
012949-APPL. The Appeal of the Conditional Use Permit fails to conform to the City’s legal
requirements by missing the 15-day deadline. Mistaken advice from City staff did not materially
alter Appellant’s rights and thus dismissal is warranted.
5
VI. Potential Motions
The following are the two motions the Governing Body may make in response to this action
item:
Option 1: I move to accept the City Attorney’s recommendation and deny Land Use Appeal
#2026-012949-APPL for the reasons specified in the City Attorney’s written recommendation.
Option 2: I move to reject the City Attorney’s recommendation and set Land Use Appeal #2026-
012949-APPL for public hearing because [include brief explanation of reasons].
Attachments:
A: Verified Appeal Petition (Aug. 10, 2026)
B: Land Use Director Appeal Petition Conformity Review (Oct. 1, 2026)
C: Planning Commission’s Findings of Fact and Conclusions of Law for Case #2025-11756 (Sep.
3, 2026)
D: Staff Report for Case #2025-11753 and Case #2025-11756
Attachment A: Verified Appeal Petition (August 10, 2026)
UUJE3
APPEL ANT INEARMATION
Thomas Trust Holdings, LLCName:
Address: 340 East Berger Street te
BY-kE iJh/*
Email Address: thomasprop@newmexico.comPhone:
Additional Appellant Names: TP-SFSS, LLC; Thomas Properties-NM, LLC
Correspondence Directed to: BothAppellant Applicant
E-mail Address:Phone:
AGENI AUTHQRIZATIQNIEAPDL ICABLE)
1 am/We are the owner(s) and record title holder(s) of the property located at:
l/we authorize
Date:
SUBJECLOF APPEAL
1802 and 1750 Cerrillos Road, 1361 Fourth Street, and 3 RD Berry Avenue, Santa Fe, NMLocation of Subject Site:
Case Number: 2025-11756 Permit Number (if applicable):
Other Final Determination of PLUD DirectorIssuance of Building PermitFinal Action Appealed:
• Planning Commission BCD-DRC
Board of Adjustment Historic District Review Board
2:3t
%io 240 (Receipt Attached)
(mdrkww V+( 01294 Page 3 of 4Revised 2/27/26
VERIFIED APPEAL PETITION
I CITY OF SANTA FE PLUD-17
Signed:
Signed:
Time Filed:
Date Filed:
87592
ZIP Code
Final Action of
Board or Commission:
Suite/Unit #
NM
State
87505
ZIP Code
Suite/Unit #
NM
State
LAND USE STAEEON IV.
Fee Paid: $ 200
Staff Signature:
Project Name: DXD Self-Storage / Empire Self Storage Project
Applicant or Owner Name: Amatren, LLC
Company Name: Amatren, LLC
Name (First, Last): See continuation sheet for agents
Address: P.O. Box 5587
Street Address
Santa Fe
City
Street Address
Santa Fe
City
505-983-3131
Two originals of this form must be filed. The Land Use Department Director or their designee will enter the date and
time of receipt and initial both original copies. See Section 14-2.1.B.5.IV for the procedure.
unur
to act as my/our agent to execute this application.
Date:
GIEE3
BASISQESIANDINC
Basis for Appeal: • The facts were incorrectly determined • Ordinance/laws were violated and/or misrepresented
B. EXPLAIN TI BASIS FOR APPEAL Please detail the basis for Appeal here (be specific):
See attached Statement of Grounds and PLUD-17 Continuation Sheet; both incorporated by reference.
SIGNATURE & VERIFICATION
I hereby certify that the documents submitted for review and consideration by the City of Santa Fe have been
Appellant Signature:
Agent Signature: Date:
I/We Forrest R. Thomas, Manager of each Appellant LLC , being first duly sworn, depose,
and say: l/We have read the foregoing appeal petition and know the contents thereof and that the same are true to
S2)4 Signature
Print Name
NOTARY PUBLIC -----------day of
Revised 2/27/26 Page 4 of4
VERIFIED APPEAL PETITION
CITY OF SANTA FE PLUD-17
Description of the final action appealed from, and date on which final action was taken:
June 4 approval; City confirmed July 9 deemed date and 30-day deadline. See continuation.
Forrest R. Thomas
Print Name
Subscribed and shown to before me this 10
, 20 20 .
My commission expires:
Ll/G/Zo3ox MCKENZIE RYLIE ROBINSON
Bet Notary Public
CSPP State of New Mexico
25 Comm. #2009132
My Comm. Exp. Apr 6, 2030
Augu- it
fulgeall’
Check here if you have attached a copy of the final action that is being appealed.
A. DESCRIPTION OF HARM Describe the harm that would result to you from the action appealed (attach additional pages if
necessary):
See attached PLUD-17 Continuation Sheet for standing and description of harm.
prepared to meet the minimum standards outlined in the Land Development Code, SFCC Chapter 14, as amended.
Failure to meet these standards mayresult in the rejection or postponement of my application.
AA(C-—Date:
Appellant/s
sgnak&ro-
PLUD-17 CONTINUATION SHEET
Case 2025-11756 | Special Use Permit | Attachment page 1
Standing and Harm
Thomas Trust Holdings, LLC and TP-SFSS, LLC received mailed notice of the June 4, 2026 Planning Commission
hearing and own adjacent or affected real-property interests. Thomas Properties-NM, LLC is the sole member of TP-
SFSS, LLC and manages affiliated real-property activities. Forrest R. Thomas is Manager of all three LLCs and is
authorized to act for each.
The Special Use Permit affects Appellants' economic, environmental, aesthetic, access, operational, and property
interests, including traffic and circulation, pedestrian and emergency access, corridor character and compatibility,
lighting, drainage, landscaping, and use and enjoyment of affected property.
Authorized Basis for Appeal
Current SFCC Section 14-2.l(B)(5)(IV)(b) allows an appeal only for: (1) noncompllance of a final action with Chapter 14
or Sections 3-21-1 through 3-21-14 NMSA 1978; (2) incorrect application of Chapter 14; or (3) a decision lacking
substantial evidence. This appeal is based only on those authorized grounds, as mapped in the attached Statement of
Grounds. The City Staff Report states that these applications were received in December 2025 and reviewed under the
prior Land Development Code, so the merits grounds rely primarily on the former substantive criteria actually applied by
the City.
Without waiving that position, if corresponding current provisions are determined to govern, Appellants assert the same
record-based challenges under current SFCC Section 14-2.1(F)(2)(IV)(a) and other applicable current provisions.
Current SFCC Section 14-1.9(D) is preserved as additional transitional support to the extent its application-completeness
requirement is satisfied.
Final Action and Timeliness
The Planning Commission voted to approve the applications June 4, 2026. The City later advised that July 9 was the
deemed final-action date. Following consultation with the City Attorney’s Office, the Planning and Land Use Director
advised Appellants in writing that the 30-day appeal deadline applies to both Case 2025-11753 and Case 2025-11756.
Under current SFCC Section 14-9.1(D), the Saturday, August 8 deadline moved to Monday, August 10. This appeal is
tendered August 10 and is timely under the City’s written determination. Appellants preserve all arguments concerning
the legal effect of any later new. amended, or materially altered written decision, including any appeal rights arising from
such action.
Applicant I Owner and Agents
Amatren, LLC, P.O. Box 5587, Santa Fe, NM 87592.
Applicant agent: Lisa Martinez, B Constructiv, LLC, 3201-C Zafarano Drive, Suite 111, Santa Fe, NM 87507.
Additional agent/counsel: Joseph M. Karnes, Sommer Karnes & Associates, LLP, 125 Lincoln Avenue, Suite 221, Santa
Fe, NM 87501.
Relief Requested
Primary Relief. Reverse the Planning Commission’s approval of Case 2025-11756. The Special Use Permit
is the discretionary land-use authorization necessary for the proposed self-storage use, and the record
presented did not establish the mandatory public-interest finding and the mandatory finding of compatibility
and adaptability required for approval.
Alternative Relief. If the Governing Body does not grant reversal, vacate the approval and remand for a new
determination based on a record that resolves the material traffic, safety, compatibility, adaptability, drainage,
lighting, and compliance issues and supports the required findings with substantial evidence.
Appellants
Representative
Contact
Mailing
Thomas Trust Holdings, LLC; TP-SFSS, LLC; Thomas Properties-NM, LLC
Forrest R. Thomas, Manager of each Appellant LLC
505-983-31311 thomasprop@newmexico.com
340 East Berger Street, Santa Fe, New Mexico 87505
DXD Self-Storage / Empire Seif Storage Project - Case 2025-11756 | Special Use Permit Appeal
Incorporated into the accompanying Verified Appeal Petition on City Form PLUD-17.
Appellants and Contact
STATEMENT OF GROUNDS SUPPORTING VERIFIED APPEAL PETITION
Case 2025-11756 - Special Use Permit | DXD Self-Storage / Empire Self Storage Project
Case 2025-11756 | Special Use Permit 1 Attachment page 2
1. This appeal fits the three grounds allowed by current Chapter 14.
Current SFCC Section 14-2.1(B)(5)(IV)(b) limits this appeal to noncompliance with Chapter 14, incorrect
application of Chapter 14, and lack of substantial evidence. The principal basis for the Special Use Permit
appeal is lack of substantial evidence supporting the mandatory public-interest finding and the mandatory
finding of compatibility and adaptability. The appeal also challenges the application of Chapter 14 where the
Commission treated unresolved compliance matters and future corrections as sufficient to support findings
that had to be supported when approval was granted, and it challenges specific identified code
noncompliance described below.
Former SFCC Section 14-3.6(D)(1) required the Commission, before granting the Special Use Permit, to find
that granting it would not adversely affect the public interest and that the use and associated buildings were
compatible with and adaptable to buildings, structures, and uses of abutting and nearby properties. The Staff
Report presented each as a required criterion and marked each “YES." Those findings were prerequisites to
approval. The applicant therefore had to present an evidentiary record sufficient for the Commission to make
them. (Staff Report, pp. 12-13.)
Appellants rely primarily on the former substantive criteria actually applied by the City. Without waiving that
position, if corresponding current provisions are determined to govern, the same challenges are asserted
under current SFCC Section 14-2.1(F)(2)(IV)(a), which contains materially the same necessary public-interest
finding and the mandatory finding of compatibility and adaptability, and other applicable current provisions.
Current SFCC Section 14-1.9(D) is preserved as additional transitional support to the extent its application
completeness requirement is satisfied.
2. The mandatory public-interest finding was not established. [Authorized Grounds 2 and 3]
The applicant's own response relied on redevelopment of a property vacant since about 2019, asserted low-
intensity operations and low traffic, compliance with zoning standards, community gathering and office space,
a public dog park, solar generation, and the creative workspaces. Staff then concluded that the public interest
was protected because, subject to conditions, the application complied with Chapter 14's minimum health,
safety, and welfare standards. (Staff Report, pp. 12-13.)
Those positive features are relevant, but they do not themselves establish the required finding for the primary
use. Redevelopment of a vacant property can be desirable without establishing entitlement to this particular
discretionary use. The community room, dog park, solar improvements, and creative workspaces are
community-facing components of a predominantly self-storage development. The required question remained
whether granting this Special Use Permit, on this site and on the record presented, would not adversely affect
the public interest.
The record did not establish that conclusion. The public-interest case depended materially on low projected
traffic, safe and workable access, compatibility with the surrounding area, and compliance with the Code's
health, safety, and welfare standards. As the record discussed below shows, those premises remained
materially unresolved when the Commission approved the Special Use Permit.
3. Low projected trip volume did not establish traffic safety at this location. [Authorized
Ground 3]
CENTRAL ISSUE. Self-storage in the C-2 district was not permitted by right. To obtain the Special Use
Permit, the applicant had to establish, through evidence in the record, the mandatory public-interest finding
and the mandatory finding of compatibility and adaptability required by former SFCC Section 14-3.6(D).
Approval was not available unless that showing was made. The record presented did not establish those
findings.
Case 2025-11756 | Special Use Permit | Attachment page 3
Although low projected traffic was offered as evidence that the Project would not adversely affect the public
interest, traffic volume alone does not establish traffic safety. The character of the traffic and the roadway
context matter. The Impact of Traffic Assessment itself describes Cerrillos Road as a principal arterial with
higher traffic and speed, bike lanes, and a local bus route. The Project includes storage, office/community
uses, a dog park, flex-workshop space, and multiple access points. (Impact of Traffic Assessment, pp. 1-3;
Staff Report, pp. 7-9.)
The approved development-plan materials include turning templates for an SU-40 single-unit truck. Public
hearing testimony specifically raised the safety implications of trucks towing trailers and rental moving trucks,
including drivers unfamiliar with those larger vehicles, on Cerrillos Road and surrounding streets. The site
also places four vehicular entrances and a pedestrian connection between the two project sites in the
immediate area of the City fire station. Staff expressly told the Commission that access, frontage
coordination, and fire-station operations were distinct issues and that the traffic assessment was not being
presented as "fire operations clearance." (Development Plan/Paving materials; June 4 hearing, approximately
23:46-24:34 and 1:25:52-1:26:17.)
The public-interest inquiry therefore could not end with the aggregate number of predicted trips. The existing
Cerrillos Road infrastructure compounds that concern. Some nearby intersections lack dedicated turn lanes,
while others have short turn pockets that provide limited space for deceleration and queuing. Public hearing
testimony described crossing Cerrillos Road as already "quite a dangerous feat with a normal vehicle." For a
use expected to generate trucks towing trailers and rental moving trucks, the applicant had to establish that
those larger-vehicle movements could be accommodated at this location without an adverse public-interest
effect. The record does not supply substantial evidence resolving that site-specific and use-specific safety
question.
4. The traffic record does not explain the fourteen creative office/workshop units.
[Authorized Ground 3]
The traffic assessment describes the secondary site as including drive-up storage, office, and flex-workshop
space and identifies ITE land-use categories for Mini-Warehouse, Small Office Building, Recreational
Community Center, and Dog Park. Table 2 separately lists "151 -14 Units" and assigns that component zero
AM peak-hour trips and zero PM peak-hour trips. The total analysis then projects only 10 AM and 17 PM
peak-hour trips and concludes that a full Traffic Impact Analysis is not anticipated to be required. (Impact of
Traffic Assessment, pp. 1-3, Table 2.)
The hearing record describes the same fourteen units as individually leasable creative office/workshop-style
spaces for uses such as startup businesses, studios, woodworking, cabinet making, podcasting, and craft
work. When asked about operating hours, the applicant stated that tenants would have individual access
cards and could come and go "just like it was their office building." (Staff Report, pp. 2-3; June 4 hearing,
approximately 51:48-53:18 and 1:01:39-1:02:00.)
The record does not explain how those operational descriptions were reconciled with zero peak-hour trips for
the fourteen-unit component. The omission is especially material because the report projects only 10 AM and
17 PM peak-hour trips for the entire development. Against totals that small, traffic from fourteen
independently accessible office/workshop units could represent a substantial portion of the Project's total
peak-hour traffic before any trips from the storage, community room, dog park, and other uses are
considered. Because low projected traffic was a material part of the applicant's and Staff's public-interest
case, the unexplained zero-trip treatment is material to whether the required finding is supported by
substantial evidence. (Impact of Traffic Assessment, Table 2; Staff Report, pp. 2-3.)
5. The mandatory finding of compatibility and adaptability was not established on the record
presented. [Authorized Grounds 2 and 3]
Staff itself told the Commission that Special Use Permit review was “not simply a zoning compliance check”
and required consideration of public interest and compatibility at this location. Yet Staff's response to the
criterion requiring both compatibility and adaptability relied principally on surrounding C-2 uses, the fact that
storage is potentially allowed with a Special Use Permit, neutral stucco architecture, zoning compliance, and
elimination of existing nonconformities. (Staff Report, p. 13; June 4 hearing, approximately 17:41-17:56.)
Case 2025-11756 j Special Use Permit ] Attachment page 4
The record contained substantial contrary concerns requiring an evidentiary basis before the mandatory
finding could be made. Early Neighborhood Notification comments raised pedestrian crossings, transit, traffic,
and community-serving features. Written public comment raised fire-station proximity and emergency-safety
review. Hearing testimony raised corridor character and traffic safety. A commissioner described the building
as attractive in isolation but "extremely out of character" for the neighborhood, and later agreed that the
landscaping and screening concerns raised in public comment were well taken. (Staff Report, p. 14; June 4
hearing, approximately 1:39:30-1:40:03 and 1:51:45-1:52:25.)
The adaptability component presents an additional evidentiary gap. In its Applicant Response, the applicant
stated: "The self-storage building design lends itself to being adaptable to other uses. The self-storage units
within the building shell can be modified to adapt to different uses." Staff's response, however, analyzed
surrounding uses, zoning, architecture, and compatibility; it did not separately identify evidence showing that
a substantial alternative use could actually be accommodated by the approved building and site. The
approved Development Plan calculates 69 required parking spaces and provides 73 for the entire Project.
Under former Table 14-8.6-1, mini-warehouses required only one parking space per 10 storage areas, while
representative alternative uses carried materially greater parking requirements, including one space per 350
square feet of net leasable area for non-medical office, one per 400 square feet for neighborhood
grocery/laundromat, and one per 500 square feet for warehouse/distribution. The record contains no analysis
showing whether a substantial conversion could satisfy those parking requirements, where materially
additional parking could be accommodated, or whether other site and building requirements applicable to an
alternative use could be met. (Staff Report, p. 13; Development Plan, Sheet A.101; former Table 14-8.6-1.)
The significance of the public and commissioner concerns, together with this unaddressed adaptability
question, is that they bear directly on the mandatory criterion requiring both compatibility and adaptability.
Zoning eligibility and the applicant's general assertion that the self-storage units within the building shell can
be modified to adapt to different uses do not provide substantial evidence that the proposed use and
associated buildings are both compatible with and adaptable to buildings, structures, and uses of abutting
and nearby properties. The record therefore does not demonstrate an adequate evidentiary basis for the
Commission to make that mandatory finding before approval.
6. The City's own technical review confirms that material compliance remained unresolved.
[Authorized Grounds 1, 2 and 3]
The City's Conditions of Approval and Technical Corrections ("Attachment A" in the administrative record)
provide additional confirmation that the required showing was not complete when the Commission acted.
Technical Correction 39 states that the "Current analysis shows a violation" because an increase in peak
stormwater flows is not allowed by SFCC Section 14-8.2(D)(4)(b)(i), and the review required additional
drainage and runoff-volume analysis. Technical Correction 37 separately states that the photometries did not
meet Code requirements. These matters were assigned for correction prior to recordation rather than
resolved before the June 4 approval. (Attachment A, Technical Corrections 37, 39-44.)
The significance of those identified deficiencies extends beyond the underlying engineering and lighting
corrections. They constitute the City's own contemporaneous evidence that material Code compliance had
not yet been demonstrated when Staff relied on compliance with minimum health, safety, and welfare
standards to support the public-interest finding. They therefore reinforce the authorized appeal grounds of
noncompliance with Chapter 14, incorrect application of Chapter 14, and lack of substantial evidence.
7. Taken together, the record did not establish the mandatory findings when approval was
granted. [Authorized Grounds 2 and 3]
The unresolved traffic-safety questions, unexplained treatment of the fourteen office/workshop units, site
specific compatibility concerns, the unsupported adaptability conclusion, and City-identified compliance
problems are not a collection of isolated technical objections. Together they show that the evidentiary record
necessary to support the mandatory public-interest finding and the mandatory finding of compatibility and
adaptability had not been established when the Commission approved the Special Use Permit.
The Code required those affirmative findings before approval. The record presented did not contain
substantial evidence sufficient to support the required public-interest finding and the mandatory finding of
Case 2025-11.756| Special Use Permit | Attachment page 5
compatibility and adaptability at the time of approval. Accordingly, the Special Use Permit decision lacks
substantial evidentiary support and reflects an incorrect application of Chapter 14.
8. Relief
Primary Relief. The Governing Body should reverse the Planning Commission's approval of Case 2025-
11756. The Special Use Permit was the discretionary authorization necessary for the proposed self-storage
use in C-2, and the record presented did not establish the mandatory public-interest finding and the
mandatory finding of compatibility and adaptability required for that approval.
Alternative Relief, If the Governing Body does not grant reversal, Appellants request that the approval be
vacated and the matter remanded for a new determination based on a record that resolves the material
traffic, safety, compatibility, adaptability, drainage, lighting, and compliance issues identified above and
supports the required findings with substantial evidence. Appellants also request any other relief authorized
by law.
LeoeS%
8
7 4
4r INVOICE (INV-00118794)s)9
INVOICE DESCRIPTIONINVOICE DATEINVOICE NUMBER
NONE08/10/2026INV-00118794
TOTALFEE NAMEREFERENCE NUMBER
$200.002026-012949-APPL Appeal Fee
$200.001802 Cerrillos Rd Santa Fe, NM 87505 JB TOTAL
$200.00TOTALREMITTANCE INFORMATION
$200.00
$200.00
$400.00
$400.00
Change due $0.00
Paid by: LLC, THOMAS TRUST HOLDINGS
Signature: ....
Thank you for your payment
CUSTOMER COPY
August 10, 2026 Ver. 05
$400.00
$400.00
Subtotal
Total
Page 1 of 1
6/24/2019
City of Santa Fe
PO Box 909
Santa Fe, NM 87504
Tenders
CREDIT CARD
MasterCard
08/10/2026 03:01PM Michael R
003293-0005
BILLING CONTACT
THOMAS TRUST HOLDINGS LLC
340 E BERGER ST
Santa Fe, NM 87505
LLC, THOMAS TRUST HOLDINGS
2026-012950-APPL
2026 INV-001 18795
Appeal Fee - Plan - All
Appeals
EG INVOICE
LLC, THOMAS TRUST HOLDINGS
2026-012949--APPL
2026 INV-00118794
Appeal Fee - Plan - All
Appeals
City of Santa Fe
200 Lincoln Ave.
Santa Fe, New Mexico 87504-0909
City of Santa Fe, NM
DEPARTMENT
200 Lincoln
Sante Fe, NM 87507 4808
?.
%
o
p
n
o
9/
59
Attachment B: Land Use Director Appeal Petition Conformity Review
(October 1, 2026)
LAND USE DIRECTOR APPEAL PETITION CONFORMITY REVIEW
Heather L. Lamboy, AICP
Date: October 1, 2026
Appellant: Thomas Trust Holdings, LLC
Forrest Thomas
Address: 1802 & 1750 Cerrillos Rd, 1361 Fourth St, and 3 Berry Avenue
Reason for Appeal: Planning Commission Approval of the DXD Self-Storage/Empire Self-Storage
Conditional Use Permit based on the incorrect application of Chapter 14 and a
decision lacking substantial evidence.
Verified Petition: 2026-012949-APPL
Filing Date: 8/10/2026
Case/Title/Permit: Appeal of Planning Commission decision to approve the DXD Self-Storage
Development Plan and Conditional Use on 2.72 acres for an indoor self-storage
facility (Case No. 2025-11756)
Final Action: Is there a final, appealable action? [SFCC 1987 § 14-2.1.B.5.IV.a.1.i), Land Use Board Final
Action] Yes. The decision was considered final on July 9, 2026.
Time: Is the appeal timely? No. The Conditional Use appeal period is shorter than the Development Plan
appeal period. The appeal period is 15 days from the date of the final action date of July 9, 2026. Stating
that it was unclear as to the appeal period, the applicant filed by August 10, 2026, which was not timely.
Since there were two approvals, a Development Plan and Conditional Use, [SFCC 1987 § 14-
2.1(B)(5)(IV)(e)]. The appeal was filed on August 10, 2026, and did not meet the deadline for a
Conditional Use appeal, which was July 24, 2026. The appeal petition fee was paid on August 10, 2026.
Valid Basis: Has Appellant stated a basis for appeal? [SFCC 1987 § 14-2.1.B.5.IV.b.2] Yes. The Appellant is
contesting the application of Chapter 14 and expresses disagreement with the Planning Commission’s
approval on the basis that the required public-interest finding was not established by the traffic and
access record, and that the mandatory finding of compatibility and adaptability was not established on
the record.
2
Standing: Does Appellant have standing? [SFCC 1987 § 14-2.1.B.5.IV.c.3] Yes. Mr. Forrest Thomas of
Thomas Trust Holdings received a mailed notice of the public hearing.
Service: If the Appellant is not the Applicant and there is an Appellee, did the Appellant timely provide
the Applicant with a copy of the appeal? [SFCC 1987 § 14-2.1.B.5.IV.h.2] Yes. The appellant provided
timely delivery of a copy of the appeal petition to Joseph Karnes, the agent for the applicant, Amtren,
LLC.
Additional Background: On August 4, 2026, the Appellant contacted me to inquire about the deadlines
for filing the appeal of the Conditional Use Permit and the Development Plan. On August 7, 2026, I
informed him orally that, after consultation with the City Attorney’s Office, a 30-day deadline would
apply to both appeals. After further review, as outlined here, that advice to the Appellant was mistaken
and the 15-day deadline applies.
Attachments:
Verified Appeal Petition
Filing Fee invoice/receipt
Staff Report Packet
Attachment C: Planning Commission’s Findings of Fact and
Conclusions of Law for Case #2025-11756 (Sep. 3, 2026)
Attachment D: Staff Report for Case #2025-11753 and Case
#2025-11756
Page 1 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
Case Numbers 2025-11753
2025-11756
Site Map
Hearing Date June 4, 2026
Agent Sommer Karnes & Associates LLP
B Constructiv LLC
Applicant Amatren, LLC
Request Development Plan
& Special Use Permit
Location 1802 Cerrillos Rd, 1750 Cerrillos Rd, 1361
Fourth St, 3 RD Berry Ave
Case Manager George Terry
Zoning C-2 (General Commercial)
Overlay Cerrillos Rd Highway Corridor Protection
District (Zone 1),
Suburban Archeological Review District
Pre-App
Meeting
June 26, 2025
ENN Meeting October 6 & 23, 2025
Proposal The applicant requests approval of a
Development Plan and Special Use Permit
for a mixed-use storage facility.
Case #2025-11753. 1802, 1750 Cerrillos Rd, 1361 Fourth St, and 3 RD Berry Ave Development
Plan. Sommer Karnes & Associates LLP and B Constructiv LLC, “Agent,” for Amatren, LLC, owner and
applicant, “Applicant,” requests approval of a Development Plan on 2.72 acres for an indoor self-storage
facility containing climate-controlled storage and community offices; creative office suites (mini-storage
units); and a community dog park. The properties are zoned C-2 (general commercial) and located within
the Cerrillos Road Highway Corridor (CRHC) Protection District Zone One and the Suburban
Archaeological Review District. (George Terry, Case Manager, agterry@santafenm.gov)
Case #2025-11756. 1802, 1750 Cerrillos Rd, 1361 Fourth St, and 3 RD Berry Ave Special Use
Permit. Sommer Karnes & Associates LLP and B Constructiv LLC, “Agent,” for Amatren, LLC, owner and
applicant, “Applicant,” requests approval of a Special Use Permit to develop an indoor self-storage
facility containing climate-controlled storage and community offices; creative office suites (mini-storage
units); and a community dog park on 2.72 acres. The properties are zoned C-2 (general commercial) and
located within the Cerrillos Road Highway Corridor (CRHC) Protection District Zone One and the
Suburban Archaeological Review District. (George Terry, Case Manager, agterry@santafenm.gov)
Planning and Land Use Department
Planning Commission Staff Report
Page 2 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
I. RECOMMENDATION:
Staff recommends that the Planning Commission APPROVE the following cases, subject to the Conditions
of Approval and Technical Corrections outlined in Attachment A of this report.
1. Case #2025-11753: 1802 Cerrillos Rd Development Plan
2. Case #2025-11756: 1802 Cerrillos Rd Special Use Permit
Two motions will be required for this case:
1. APPROVE Case #2025-11753, “1802 Cerrillos Rd Development Plan,” based on the findings in the
Staff Report and subject to the Conditions of Approval and Technical Corrections outlined in
Attachment A.
2. APPROVE Case #2025-11756, “1802 Cerrillos Rd Special Use Permit,” based on the findings in the
Staff Report and subject to the Conditions of Approval and Technical Corrections outlined in
Attachment A.
II. EXECUTIVE SUMMARY
The subject property includes four parcels totaling approximately 2.72 acres: 1802 Cerrillos Rd (1.74
acres), 1750 Cerrillos Rd (0.18 acres), 1361 Fourth St (0.56 acres), and 3 RD Berry Ave (0.24 acres). The
parcels straddle Fourth St and are located southwest of the Santa Fe Indian School. The property is the
former Empire Builders site.
The Applicant requests approval of a Development Plan and Special Use Permit to demolish the existing
structures and redevelop the property as a mixed-use self-storage facility across four buildings totaling
approximately 102,000 square feet of gross floor area. The development will include 480 indoor climate-
controlled storage units of varying sizes across three floors, associated community office/community
room space on Site 1, and 14 creative office/workshop-style mini-storage units on Site 2, together with
parking and a community dog park.
These applications were received in December 2025 and therefore have been reviewed under the prior
version of the Land Development Code, before recodification (Ordinance 2025-25).
The Applicant has complied with Subsections 14-3.1(E) "Pre-Application Conferences", 14-3.1(F) "Early
Neighborhood Notification Procedures," and 14-3.1(H) "Notice Requirements".
Staff's analysis finds that the Applicant has addressed the applicable findings under SFCC Sections 14-
3.8(D) and 14-3.6(D). Staff recommends approval of both cases subject to the Conditions of Approval
and Technical Corrections identified in Attachment A.
Page 3 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
III. PROJECT ANALYSIS: DEVELOPMENT PLAN & SPECIAL USE PERMIT
Project Description
The main structure proposed, “Building 1,” fronts Cerrillos Road with parking in the rear. It is a three-
story, partially underground structure that is approximately 29 feet 6 inches tall and contains 480 indoor
climate-controlled storage units (“Site 1”). Building 1 will replace the existing Empire Builders structure.
Across Fourth Street to the east, “Site 2” includes three parcels and three additional one-story structures;
however, two of those parcels will be consolidated pursuant to the Conditions of Approval. Site 2 also
includes 1750 Cerrillos Road, which will remain a parking lot, matching its existing use. The other two
parcels south of 1750 Cerrillos Road will contain three one-story buildings with small-format creative
office/workshop-style suites, parking, and a community dog park. For purposes of this Staff Report,
“creative office suites” refers to flexible, individually leasable workspace/workshop-style units intended
for low-intensity creative, maker, small-business, studio, or similar uses with associated storage
functions. These suites are reviewed as part of the overall storage-oriented redevelopment and are not
treated as a separate conventional office complex.
Figure 2: “Site 1” on the left, “Site 2” on the right across Fourth St
Page 4 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
A Development Plan is required for this project under SFCC Section 14-3.8(B)(3)(a) which states,
“approval of a Development Plan by the planning commission is required prior to
new development that meets any of the following criteria: (a) gross floor area of thirty thousand
square feet or more and is located within any zoning district of the city.” A Special Use Permit is also
required for individual storage areas within a completely enclosed building and mini-storage units in
C-2 zones as shown in SFCC Table 14-6.1-1.
Zoning & Land Use
The Property is zoned C-2, General Commercial. The C-
2 district accommodates a broad range of commercial
and compatible uses. Storage facilities in the C-2 district
are allowed only if the Applicant is granted a Special Use
Permit.
The properties surrounding the project site are also
zoned C-2. Adjacent uses include hotels, a fire station,
auto shops, a restaurant, and another mini-storage
facility. The future land use classification for this
property and the surrounding properties is Community
Commercial. Figure 3: Zoning Map. Red is C-2, yellow is R-5, and purple is C-1.
The proposed Development Plan meets all C-2 dimensional standards shown in Table 1 below.
Table 1 – Dimensional Standards
C-2 (General Commercial) Dimensional Standards
Requirement C-2 District Standard Proposed
Height 45’ Maximum Site 1: 29’6”
Site 2: 16’
Lot Coverage 60% maximum Site 1: 37% (28,512 sq ft)
Site 2: 29% (12,448 sq ft)
Open Space 25% of total lot area
*20% if passive stormwater harvesting
provided
*15% if active stormwater harvesting is
provided
Site 1: 30.91% (23,542 sq
ft)
Site 2: 25.62% (10,831 sq
ft)
Setbacks Street: 15 ft
Side: 0 ft
Rear: 10 ft
Site 1: Street – 32’, Rear
– 64’
Site 2: Street – 15’, Rear
– 10’
*Note: The existing
Page 5 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
Empire Builders site is
not in compliance with
setbacks. This
redevelopment will bring
the property into
compliance.
SFCC Sections 14-6.2(D)(2) and (3) impose stricter limitations on storage facilities. Below are the
limitations and a summary of this project’s compliance.
Table 2 – Individual Storage Unit Limitations
14-6.2(D)(2) Individual Storage Areas Within a Completely Enclosed Building
Storage units that are not directly accessible from outside a building are subject to the following
limitations:
Limitation: Project Compliance:
a. the plan for operation of the storage area is
compatible with other permitted uses existing in
the vicinity;
Another storage facility, Santa Fe Self Storage,
exists adjacent to the southeast of the project.
b. the storage area shall not unreasonably
interfere with permitted uses because of glare,
traffic congestion or any similar nuisance;
An Impacts of Traffic Assessment was prepared
and reviewed. The proposed development does
not meet the threshold requiring a full Traffic
Impact Analysis under City TIA Guidelines.
Congestion and similar traffic-related nuisances
are not anticipated.
c. an individual storage unit shall not exceed two
hundred square feet;
The largest individual storage units proposed are
10x20 sq ft.
d. outdoor storage is prohibited on the site if
located within a C-2 district or the BCD;
Outdoor storage is not proposed.
Table 3- Mini Storage Unit Limitations
14-6.2(D)(3) Mini Storage Units
Storage units that are directly accessible from outside a building are subject to the following
limitations:
Limitation: Project Compliance:
a. a wall or fencing plan shall be submitted for
staff review and approval prior to issuance of a
construction permit. Walls or fences shall provide
a visual buffer or screen and be constructed of
opaque materials;
The applicant is proposing a 6 ft tall dark bronze
fence along the perimeter of Site 2.
b. a landscape plan meeting all the requirements The Applicant has provided a landscape plan,
Page 6 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
of Section 14-8.4 shall be submitted to the land
use director for approval prior to issuance of a
construction permit;
subject to the Conditions of Approval and
Technical Corrections in Attachment A.
c. the architecture shall be compatible with the
zoning district as approved by the land use
director. One dwelling unit, excluding
manufactured homes, is allowed as part of the
storage unit development and it must be
architecturally compatible with the storage units.
No portion of the storage units or the dwelling
unit shall exceed one story in height;
The proposed architecture has been reviewed for
compliance with the required architectural
points.
d. lighting shall be of a nature that is not intrusive
to surrounding residential uses;
The Applicant submitted a photometric plan. Final
lighting corrections remain subject to Attachment
A and SFCC Section 14-8.9.
e. mini-storage units approved after July 25, 2007 shall
comply with the following:
i. a building shall not be located fewer than one hundred
(100) feet from a residentially zoned property unless the
required landscaping buffer adjacent to the residentially
zoned property is twice the otherwise required width; and
ii. an eight (8) foot masonry wall, either stuccoed on the
outside or made of decorative block, is required along any
property line abutting a residentially zoned property.
There is residential zoning north of Site 2 (1750 Cerrillos),
across the Cerrillos Rd Right of Way. However, Staff
determined these regulations do not apply because 1) the
property that is zoned residential is owned and occupied as
a City Fire Station, and 2) the Applicant is proposing that this
parcel of Site 2 (1750 Cerrillos) will remain its current
parking lot use. No mini-storage units are proposed on this
lot.
Architecture
The project is composed of four (4) buildings proposed to use natural earth-toned stucco with accents
of stone, wood trellises, metal siding, and a mural on the west side of Site 1. The buildings will have a
footprint of approximately 41,000 square feet across the parcels, with a gross floor area of approximately
102,000 square feet. The structures will have flat roofs with parapets to screen rooftop equipment. This
development is required to meet 205 architectural points in the C-2 zoning district, and the proposed
design exceeds that requirement with 230 points. Architectural elevations and the points analysis can
be found in Attachment C-3.
Although this development is over 30,000 gross square feet, it is not required to comply with SFCC
Section 14-8.8, “Supplemental regulations for retail structures thirty thousand gross square feet or
larger.” The supplemental regulations apply to retail establishments as defined by the code. The
proposed primary use is self-storage with associated office and community components, and staff does
not classify the proposed use as a retail establishment for purposes of applying SFCC Section 14-8.8.
Page 7 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
Figure 4: Applicant renderings of southwest and northeast corners of Site 1
Access, Traffic, & Parking
The project includes four (4) vehicular entry points. There are two (2) entries on the southeast and
southwest sides of Site 1 (Fifth St and Fourth St) to provide access to the parking and loading area. There
is one (1) entry off Fourth St into the northernmost parking lot on Site 2, and another one (1) entry into
the creative studios area parking lot in Site 2 off Berry Ave.
The project is required to provide a total of 14 bike parking spaces across both sites of this development
and has done so with inverted U bike racks in two locations. Vehicular parking requirements for Site 1
are 63 parking spaces, and 6 spaces for Site 2. The applicant proposes 73 parking spaces total, spread
between three (3) lots. See Figure 2 for a visual on the parking layout. The applicant has a Condition of
Approval to provide appropriate documentation connecting Lot 1 to the rest of the Development Plan
in perpetuity to keep the freestanding parking lot connected with the development to avoid any future
creation of parking nonconformities.
An Impacts of Traffic Assessment was prepared by Souder, Miller & Associates and reviewed for the
project. The assessment evaluated the anticipated traffic associated with the proposed storage, office,
community space, and dog park uses. Based on the estimated trip generation and the City’s Traffic
Impact Analysis Guidelines, the proposed development does not meet the threshold requiring a full
Traffic Impact Analysis. The assessment estimates ten (10) AM peak-hour trips and seventeen (17) PM
peak-hour trips for the proposed development. See Attachment C-4.
This project lies in a region of Cerrillos Rd that will be altered through NMDOT project S100681 (NM/14
Cerrillos Road) beginning in approximately May 2027. The Applicant has communicated with NMDOT
regarding the site plans and site improvements to the right of way. The applicant will install a five (5)
foot wide landscape buffer along Cerrillos Rd with a six (6) foot wide sidewalk beside it. Construction of
this buffer and the connections to the curb ramps cannot be done until the NMDOT constructs their
portion first. The Applicant has a Condition of Approval to continue coordinating construction timing
with NMDOT.
Along Fifth St, Fourth St, and Berry Ave, the Applicant will install a five (5) foot wide public sidewalk. The
Page 8 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
Applicant will also install a crosswalk connecting Site 1 and 2 across Fourth St.
Terrain Management
The properties are previously disturbed and mostly consist of existing impervious areas. The Applicant
proposes to demolish existing structures and asphalt parking areas for the proposed redevelopment.
The Applicant has included an erosion control plan to mitigate runoff from the property during
construction. Once developed, the property will include eight (8) stormwater ponds for detention and
retention. Attachment A includes Conditions of Approval and Technical Corrections related to terrain
management that must be completed before recording the Development Plan.
Landscaping, Lighting, & Signage
The Applicant submitted a landscape plan including new trees, shrubs, gravel, and mulch around much
of the perimeter of the properties. The design remains subject to technical corrections prior to recording
the Development Plan. Items requiring revision include parking lot landscape islands, tree species and
placement, and additional parking lot screening shrubs. Refer to Attachment A for the applicable
Conditions of Approval and Technical Corrections.
The Applicant also provided a lighting plan that includes building-mounted outdoor lights, pole lights,
and string lights to illuminate parking areas and pedestrian pathways. Staff reviewed the photometric
data and identified Conditions of Approval and Technical Corrections that must be addressed prior to
recording the Development Plan. See Attachment A.
Signage shown in the proposed Development Plan is not approved through this application. Staff will
review proposed signs for this commercial use through the applicable sign permit process. In the CRHC
Protection District Zone 1, this property will be allowed no more than three (3) signs, none of which may
exceed fifty (50) square feet, for a total allowable sign area of no more than 150 square feet.
Utilities
The property has existing water and sewer infrastructure, and the project proposes new water, sewer,
and fire service improvements to serve the redevelopment. The City Water Division has approved the
Water Plan and Development Water Budget for the project. The approved Development Water Budget
is 1.66 acre-feet per year, which is below the five acre-feet per year threshold for water-rights transfer.
Additional water infrastructure, Agreement to Construct and Dedicate, agreement for metered service,
separate service, irrigation meter, backflow prevention, and related requirements remain subject to the
Conditions of Approval and Technical Corrections in Attachment A at the applicable later development
stages. City Wastewater did not provide comments on this project. See Attachment C-4.
Page 9 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
Fire Prevention and Emergency Access
Fire and emergency access requirements will be reviewed through the applicable International Fire Code
requirements and City fire-related conditions. All structures within the proposed Development Plan
would include fire alarm systems and sprinklers. There is fire access to Site 1 via Cerrillos Rd, Fourth St,
Fifth St, and through the parking lot on the rear (south) side of the structure. Fire access to Site 2 is
available along Fourth St, Berry Ave, and through the hammerhead parking area between Buildings 2, 3,
and 4. Fire access areas are designed to support the load of a 75,000-pound fire apparatus. The
development has two (2) existing fire hydrants on site, one of which will be relocated during
construction. Attachment A includes a Condition of Approval requiring the Applicant to maintain fire
access roads during construction in compliance with IFC 2021.
Archaeology
This project is within the Suburban Archaeological Review District. No further archaeological review is
required unless a future utility plan exceeds 550 linear feet of utility lines, or more restrictive
requirements in future amendments to Chapter 14 of the City Code.
Figure 5: Fire Plan. Red approximates fire access areas.
Page 10 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
IV. DEVELOPMENT PLAN APPROVAL CRITERIA SECTION 14-3.8(D)(1)
SFCC Section 14-3.8 governs the authority, procedures, and restrictions for Development Plans. The
criteria for approval of Development Plans are detailed below:
Criterion 1: that the Planning Commission has the authority and is
empowered to approve the development plan under the section of Chapter
14 described in the application;
Criterion Met:
(Yes/No)
YES
Applicant Response:
City Code section 14-3.8.B.3.a requires a development plan for uses with a gross floor area of 30,000
SF or more located within any zoning district of the City. The proposed project is greater than 30,000
SF and therefore requires approval of a development plan by the Planning Commission.
Staff Response:
Santa Fe City Code (SFCC) Section 14-2.3(C)(1) authorizes the Planning Commission to review and
approve or disapprove development plans.
Criterion 2: that approving the development plan will not adversely affect
the public interest; and
Criterion Met:
(Yes/No)
YES
Applicant Response:
Since the closure of Empire Builders Supply in about 2019, the Property has been vacant; giving rise to
negative issues common to vacant urban properties. Redevelopment of the Property will revitalize this
area along Cerrillos Road, including addition of amenities available to the community. As addressed
below, approving the requested applications would enhance the public interest in several ways.
Self-storage is a low intensity use that generates relatively little daily activity, traffic, noise and solid
waste generation compared to the historic use of the Property and permitted uses allowed by right in
the C-2 zone. Water use and sewage generation will be minimal.
The self-storage building has been designed to maintain a compatible scale and use type with respect
to the vicinity, while introducing high-quality architectural and site design features that elevate the
visual and functional quality of the Cerrillos Road corridor. While the maximum height limit in the C-2
zone is 45 feet, the proposed self-storage building will be less than 30 feet in height and provides an
average front setback along Cerrillos of 15 feet – greater than existing site conditions. The C-2 zone
allows for up to 60% lot coverage. The project includes lot coverage of approximately 35% and provides
32% open space, exceeding the minimum requirement of 25% which supports stormwater infiltration,
landscaping and pedestrian amenities. The Project conforms to all zoning standards, including height,
setbacks, lot coverage, parking and open space requirements and no variances are requested.
Page 11 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
Finally, as addressed above, the Project includes multiple amenities intended to serve the
neighborhood and city, including community gathering space, a community room, community offices
and a dog park open to the public. The Project will also include a rooftop solar array to supply
renewable energy to the facility, helping lower greenhouse gas emissions and contribute to the City
and region’s clean energy goals. Such amenities are not required, are not often included in commercial
projects and will benefit the public interest.
Staff Response:
The term “Public Interest” is not specifically defined in Chapter 14; however, the Governing Body has
implemented the General Plan as stated in Subsection Section 14-1.3 (General Purposes). The resulting
ordinances establish minimum standards for health, safety and welfare affecting land uses and
developments as a means to protect the public interest from within the municipality. Staff reviewed
the proposed application in accordance with these ordinances. Subject to Conditions of Approval
recommended by staff, the proposed application complies with minimum standards of Chapter 14
SFCC and would not adversely affect the public interest.
Criterion 3: that the use and any associated buildings are compatible with
and adaptable to buildings, structures and uses of the abutting property
and other properties in the vicinity of the premises under consideration.
Criterion Met:
(Yes/No)
YES
Applicant Response:
The self-storage building design lends itself to being adaptable to other uses. The self-storage units
within the building shell can be modified to adapt to different uses and the building design is
compatible with existing uses in the project vicinity. The low-intensity nature of self-storage promotes
compatibility with existing uses and the traffic generated by the use will be substantially lower than
the historic use and many uses permitted as of right within the C-2 zone.
The drive-up storage and workspaces within the lots east of Fourth Street will increase opportunities
for local entrepreneurs and small businesses to benefit from small, relatively affordable and
conveniently located workspaces. By supporting economic opportunity at the neighborhood level,
these spaces will help sustain the financial stability of individuals and families, contributing to the long-
term economic viability of the area while redeveloping a Property that has been vacant for several
years.
Staff Response:
Staff finds that the proposed uses are compatible with those in the vicinity and that the uses are
permitted with a Special Use Permit in the C-2 zoning district. Adjacent uses to the project include
hotels, a fire station, auto shops, a restaurant, and another mini-storage facility (Santa Fe Self Storage).
The architectural style of the buildings is compatible with structures in the area, as they will be mostly
neutral stucco with some accent materials. The project conforms with all C-2 zoning requirements and
eliminates existing nonconformities on the site.
Page 12 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
V. SPECIAL USE PERMIT APPROVAL CRITERIA SECTION 14-3.6(D)
SFCC Section 14-3.6 governs the authority, procedures, and restrictions for Special Use Permits. The
criteria for approval of Special Use Permits are detailed below:
Criterion 1: that the land use board has the authority under the section of
Chapter 14 described in this application to grant a Special Use Permit;
Criterion Met:
(Yes/No)
YES
Applicant Response:
City Code Table 14-6.1.1 identifies a self-storage facility within a C-2 zone as being allowed subject to
approval of a SUP. The Planning Commission has the authority to consider requests for SUPs that are
part of a development plan requesting Planning Commission review. (14-2.3.C.3)
Staff Response:
Santa Fe City Code (SFCC) Section 14-2.3(C)(3) authorizes the Planning Commission to review and
approve or disapprove special use permits when in conjunction with a development plan.
Criterion 2: that granting the special use permit does not adversely affect
the public interest; and
Criterion Met:
(Yes/No)
YES
Applicant Response:
Since the closure of Empire Builders Supply in about 2019, the Property has been vacant; giving rise to
negative issues common to vacant urban properties. Redevelopment of the Property will revitalize this
area along Cerrillos Road, including addition of amenities available to the community. As addressed
below, approving the requested application would enhance the public interest in several ways.
Self-storage is a low intensity use that generates relatively little daily activity, traffic, noise and solid
waste generation compared to the historic use of the Property and permitted uses allowed by right in
the C-2 zone. Water use and sewage generation will be minimal.
The self-storage building has been designed to maintain a compatible scale and use type with respect
to the vicinity, while introducing high-quality architectural and site design features that elevate the
visual and functional quality of the Cerrillos Road corridor. While the maximum height limit in the C-2
zone is 45 feet, the proposed self-storage building will be less than 30 feet in height and provides an
average front setback along Cerrillos of 15 feet – greater than existing site conditions. The C-2 zone
allows for up to 60% lot coverage. The project includes lot coverage of approximately 35% and provides
32% open space, exceeding the minimum requirement of 25% which supports stormwater infiltration,
landscaping and pedestrian amenities. The Project conforms to all zoning standards, including height,
setbacks, lot coverage, parking and open space requirements and no variances are requested.
Page 13 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
Finally, as addressed above, the Project includes multiple amenities intended to serve the
neighborhood and city, including community gathering space, a community room, community offices
and a dog park open to the public. The Project will also include a rooftop solar array to supply
renewable energy to the facility, helping lower greenhouse gas emissions and contribute to the City
and region’s clean energy goals. Such amenities are not required, are not often included in commercial
projects and will benefit the public interest.
Staff Response:
The term “Public Interest” is not specifically defined in Chapter 14; however, the Governing Body has
implemented the General Plan as stated in Subsection Section 14-1.3 (General Purposes). The resulting
ordinances establish minimum standards for health, safety and welfare affecting land uses and
developments as a means to protect the public interest from within the municipality. Staff reviewed
the proposed application in accordance with these ordinances. Subject to Conditions of Approval
recommended by staff, the proposed application complies with minimum standards of Chapter 14
SFCC and would not adversely affect the public interest.
Criterion 3: that the use and any associated buildings are compatible with
and adaptable to buildings, structures and uses of the abutting property
and other properties in the vicinity of the premises under consideration.
Criterion Met:
(Yes/No)
YES
Applicant Response:
The self-storage building design lends itself to being adaptable to other uses. The self-storage units
within the building shell can be modified to adapt to different uses and the building design is
compatible with existing uses in the project vicinity. The low-intensity nature of self-storage promotes
compatibility with existing uses and the traffic generated by the use will be substantially lower than
the historic use and many uses permitted as of right within the C-2 zone.
The drive-up storage and workspaces within the lots east of Fourth Street will increase opportunities
for local entrepreneurs and small businesses to benefit from small, relatively affordable and
conveniently located workspaces. By supporting economic opportunity at the neighborhood level,
these spaces will help sustain the financial stability of individuals and families, contributing to the long-
term economic viability of the area while redeveloping a Property that has been vacant for several
years.
Staff Response:
Staff finds that the proposed uses are compatible with those in the vicinity and that the uses are
permitted with a Special Use Permit in the C-2 zoning district. Adjacent uses to the project include
hotels, a fire station, auto shops, a restaurant, and another mini-storage facility (Santa Fe Self Storage).
The architectural style of the buildings is compatible with structures in the area, as they will be mostly
neutral stucco with some accent materials. The project conforms with all C-2 zoning requirements and
eliminates existing nonconformities on the site.
Page 14 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
VI. EARLY NEIGHBORHOOD NOTIFICATION
The Applicant conducted two (2) Early Neighborhood Notification (ENN) meetings on October 6, 2025
and October 23, 2025. Both meetings included presentations from the Applicant’s team followed by
questions and comments from neighbors and interested parties.
Comments and questions addressed potential impacts to existing self-storage businesses, Santa Fe’s
housing demand, pedestrian crossings near the site, transit/bus shelter needs, construction noise, traffic,
project timelines, and the proposed community-serving components of the project.
Additional comments and suggestions addressed retaining or recreating a mural similar to the existing
Empire Builders mural, ensuring attractive architecture and site design, and providing creative studio
spaces that would be accessible and useful to the community. The Applicant’s team responded to
questions during the ENN meetings. Meeting notes from the Early Neighborhood Notification meetings
can be found in Attachment C-2.
Staff also received written public comment from Lara Miller regarding Case #2025-11753 and Case
#2025-11756. The comment objected to Planning Commission action unless the application materials
and City evaluation are publicly available with sufficient time for public review. The comment also
requested access to the application materials, Staff Report, Special Use Permit findings, Development
Plan sheets, Cerrillos Road Highway Corridor Protection District analysis, Suburban Archaeological
Review District materials, departmental review comments, and proposed Conditions of Approval.
Ms. Miller’s written comment further requested that staff evaluation address the project’s location
within the Cerrillos Road Highway Corridor Protection District Zone 1 and the Suburban Archaeological
Review District, the proximity of the City fire station, Fire Department / Fire Marshal comments, and the
existing Empire Builders mural or related cultural-resource considerations. Staff has logged and
preserved the written comment in the case record. Public comments received before or during the
Planning Commission hearing will be retained as part of the public record for these cases and made
available to the Planning Commission for consideration.
VII. EXPIRATION
Per SFCC Section 14-3.19(B)(4) “Approval of a final development plan, or any development plan for which
no preliminary development plan was required, shall expire three years after final action approving it
unless actual development of the site or offsite improvements has begun and is continued pursuant to
Subsection 14-3.19(B)(6).” Approval of the Special Use Permit will share the Development Plan’s
expiration.
Page 15 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
VIII. ATTACHMENTS
ATTACHMENT A: Conditions of Approval and Technical Corrections
1. Table of Conditions of Approval
2. Table of Technical Corrections
3. Development Review Team Compiled Comments
ATTACHMENT B: Maps and Photos
1. Aerial View
2. Existing Conditions Photos
3. Current Zoning Map
4. Future Land Use Map
ATTACHMENT C: Applicant Submittals
C-1: Applications
a. Application Forms
b. Letter of Intent
c. Owner Authorization Letter
d. Legal Lot of Record
e. NMDOT Correspondence
C-2: Early Neighborhood Notification
f. ENN Meeting Summary 10-6-2025
g. ENN Meeting Summary 10-23-2025
C-3: Development Plans
a. Development Plan
b. Landscape Plan
c. Architectural Plan
d. Architectural Points Analysis
e. Material Board and Renderings
f. Stucco Detail
C-4: Utilities
a. Impacts of Traffic Assessment
b. Approved Water Plan
c. Water Budget Approval
Page 16 of 16
Case #2025-11753 Development Plan & Case #2025-11756 Special Use Permit
Planning Commission June 4, 2026, Meeting
APPROVED AS TO FORM BY THE PLANNING AND LAND USE DEPARTMENT:
Title Name Initials
Department Director Heather Lamboy
Assistant Department Director Maggie Moore MM
Planning Manager Daniel A Esquibel DAE
Senior Planner A. George Terry AGT