Historic Districts Review Board Meeting — Tue, Sep 8, 2026 · 9.d 2026-012978-HDRB. 719 Gildersleeve St., Don Gaspar Area Historic District. Contributing. Alison Kuller, owner, proposes to replace windows in the residence and casita, construct a 100 sq. ft. addition, and stucco in the color “cottonwood”. An exception is requested to 14-4.6(E)(4)(I)(a) for the replacement of historic windows. (Lani McCulley)
City of Santa Fe Administrative Approval Land Use Department | Historic Preservation Division THIS IS NOT A CONSTRUCTION PERMIT DO NOT BEGIN WORK WITHOUT A PERMIT. SUBMIT THIS FORM WITH YOUR CONSTRUCTION PERMIT APPLICATION AND RETAIN A COPY AT THE JOB Date: To: From: Be advised that per §14-5.2 SFCC 1987 the work described below at the referenced address does NOT require Historic Districts Review Board approval and is hereby staff-approved as described below. Please allow the applicant to submit for a construction permit(s) for this work if required. Project Address: 719 GILDERSLEEVE ST, Santa Fe, NM 87505 Building Permit Division April 29, 2026 Case Number: 2026-012304--ADMIN Anthony Maestas Luis OrtizContact Name: drluisortiz@gmail.comPhone Number: 505-718-9839 Email: Approved Scope of Work: Re-roof structure as submitted, ( 1700 sq. ft. ). TPO TAN Conditions of Approval: Roofing materials must not be publicly visible. There shall be no publicly visible rooftop appurtenances, no roofing material shall be on the top of the parapets and shall be flashed on interior of parapets. Not approved to replace canales or skylights. There shall be no changes to existing mechanical, line sets, or other rooftop appurtenances at this time. No other work approved at this time. PERMIT or PERMIT REVISIONFURTHER ACTIONS REQUIRED: FINAL HISTORIC INSPECTION Ver. 06 8/30//2019Page 1 of 1 GO Construction, LLC-“No job too big, No job too small, We can do it all.” 1102 8th Street Las Vegas, NM 87701 (505) 718-9839 Historic Preservation Division 719 Gildersleeve Street, Santa Fe, NM 87505 PROPOSAL LETTER To whom it may concern, This letter is to formally express each itemized element of this reroof project (719 Gildersleeve Street, Santa Fe, NM 87505). The total square footage of the project is 1,700 sq. ft. The following will occur during the reroof project (note, but not limited to): • Removal of all existing gravel from the roof (note: gravel will be repurposed and reused for landscaping on other projects.) • Clean, tear off, inspect, and remove the existing system down to the decking • Inspect and replace any decking as needed • Prepare decking and install Poly iso insulation • Install Versico 60 mil TPO on roof (Tan by the customer/HPD) • Install pipe boots on all penetrations • Wrap Parapets with TPO and Seal all penetrations • Coat all canales and flash all skylight curbs with TPO • Install pipe boots and paint all pipe jacks to match TPO • Install TPO-coated termination metal on all parapets • Flash canales with non-reinforced detail membrane • Seal all penetrations and flash all skylight curbs with TPO • Remove and dispose of all trash and debris from the job site (this includes, but is not limited to, waste containers and porta-potties). Thank you for your attention to this matter and to our roofing business in New Mexico, which always aims to offer our best price with the highest quality. If you have any questions, please do not hesitate to contact us at 505-718-9839 or via email at drluisortiz@gmail.com. We appreciate your support for our community, GO Construction, LLC, our hard-working employees, and our efforts to enhance the facilities for generations to come. Respectfully, Luis Ortiz, Ph.D. Owner, GO Construction, LLC Phone: 505.718.9839 | 505.718.9835 Email: drluisortiz@gmail.com | Website: drluisortiz.com Description R-Tech FF (Fanfold) is a high-performance sheathing consisting of a superior closed-cell, lightweight and resilient expanded polystyrene (EPS) with advanced polymeric laminate facers. The core of R-Tech is the same high-quality as our InsulRoof brand insulations, and meets or exceeds the requirements of ASTM C578, Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation. In addition, R-Tech has excellent dimensional stability, compressive strength and water resistant properties. Uses R-Tech FF is ideal in recover applications, and is well-suited for single-ply roof applications that employ mechanically fastened or ballasted TPO, PVC, EPDM and CSPE membranes. Consult local building codes and membrane manufacturers for system requirements. Advantages Labor Savings. R-Tech FF comes in 200 ft2 bundles, and is lightweight enough that the average roof mechanic can carry an R-Tech bundle under each arm (a total of 4 squares). Competing 4’ x 8’ recover products would require 13 sheets to cover 4 squares, and weigh almost 5 times as much as R-Tech FF. User Friendly. The R-Tech manufacturing process ensures that it will lay flat during installation, eliminating the thermoplastic roof system seam-welding issues that are experienced with other FF products. Versatile. The unique polymeric laminate facers allow single- ply membranes, including PVC, to be installed directly over R-Tech without additional slip sheets or divorcement. Cost-Effective. R-Tech is typically less expensive than other recover products, requires fewer fasteners per square foot, and is easier to handle. Environmentally Friendly. It contains no formaldehyde or HCFCs, may contain recycled material, and has a foam core that is 100% recyclable. Proven Performance. The same fundamental chemistry has been in use since the mid-1950s, so the actual performance of the product is well known. Water-Resistant. R-Tech is hydrophobic (does not readily absorb moisture) and does not promote the migration of moisture into the insulation. Code Approvals. R-Tech has numerous recover listings with Underwriters Laboratories. Please refer to UL’s Roofing Materials Directory or contact your Insulfoam representative for additional information. Sizes R-Tech FF is available in nominal thicknesses of 3/8”, 1/2” and 3/4” with the 4’ x 50’ FF (2 squares). Individual panel sizes within the FF bundle are 2’ x 4’. R-Tech is also available in 4’ x 8’ units. Installation Recommendations One fastener is to be placed at each corner of the leading and trailing edges, and thereafter at a rate of one fastener every 12 square feet placed on alternating sides of the sheet. Fasteners are to be 6” from the board’s edge. When used with dark colored membranes, R-Tech should be installed with the silver or metallic side facing up. Note: Some membrane manufacturers may require a higher density of fasteners for their warranted systems. Consult the membrane manufacturer for specific requirements. Nationwide Manufacturing n Toll Free: (800) 248-5995 n www.Insulfoam.com INSULATION ENGINEERED TO MAKE A DIFFERENCE. Nationwide Manufacturing n Toll Free: (800) 248-5995 n www.Insulfoam.com 11013-05/16 INSULATION ENGINEERED TO MAKE A DIFFERENCE. Typical Physical Poperties of R-Tech* Property Type I Type VIII Type II Type IX Test Method Compressive Strength (psi, 10% deformation) 13 16 20 28 ASTM D1621 Flexural Strength (psi) 33 40 50 70 ASTM C203 Water Vapor Transmission (perms) < 1.0 < 1.0 < 1.0 < 1.0 ASTM E96 Typical Physical Properties of InsulFoam (foam core)* Property Type I Type VIII Type II Type IX Test Method Nominal Density (pcf) 1.0 1.25 1.5 2.0 ASTM C303 C-Value (Conductance) BTU/(hr•ft2•°F) @ 25° F (per inch) @ 40° F @ 75° F .23 .24 .26 .220 .235 .255 .21 .22 .24 .20 .21 .23 ASTM C518 or ASTM C177 R-value (Thermal Resistance) (hr•ft2•°F)/BTU @ 25° F (per inch) @ 40° F @ 75° F 4.35 4.17 3.85 4.54 4.25 3.92 4.76 4.55 4.17 5.00 4.76 4.35 ASTM C518 or ASTM C177 Compressive Strength (psi, 10% deformation) 10 - 14 13 - 18 15 - 21 25 - 33 ASTM D1621 Flexural Strength (psi) 25 - 30 32 - 38 40 - 50 55 - 75 ASTM C203 Dimensional Stability (maximum %) < 2% < 2% < 2% < 2% ASTM D2126 Water Vapor Transmission (perms) 2.0 - 5.0 1.5 - 3.5 1.0 - 3.5 0.6 - 2.0 ASTM E96 Absorption (% vol.) < 4.0 < 3.0 < 3.0 < 2.0 ASTM C272 Capillarity none none none none – Flame Spread < 20 < 20 < 20 < 20 UL 723 Smoke Developed 150 - 300 150 - 300 150 - 300 150 - 300 UL 723 *Properties are based on data provided by resin manufacturers, independent test agencies and Insulfoam. Features and Benefits • Living Building Challenge “Red List Free” – Declare Label • VersiWeld TPO is available in 4-, and 6-ft (121.92 cm and 182.88 cm) perimeter sheets and 8-, 10-, 12-, and 16-ft (243.84 cm, 304.80 cm, 365.76 cm, and 487.68 cm) VersiWeld field sheets* • VersiWeld High Slope TPO is available in 5', 10', and 16' (152.40 cm, 304.80 cm, and 487.68 cm) sheets • HS formula opens assemblies for slopes greater than ½" over combustible and non-combustible deck types where standard TPO is restricted • Outstanding puncture resistance and excellent fire resistant assemblies • Environmentally friendly and stable formulation • Excellent resistance to impact and low temperatures • Excellent chemical resistance to acids, bases and restaurant exhaust emissions • UL 2218 Class 4 hail rating • Manufactured with non-halogenated flame retardants • Exceptional resistance to heat, solar UV, ozone and oxidation • Manufactured using a hot-melt extrusion process for complete scrim encapsulation • Enhanced with the OctaGuard XT weathering package • Standard Colors: • Special Colors: * VersiWeld HS Special Color TPO membranes are available in 5'- and 10'-wide sheets. Refer to Versico’s VersiWeld TPO Color Palette Sell Sheet for details. VersiWeld 80-mil in special colors are limited to warranties up to 20 years. VersiWeld® TPO Reinforced Membrane Overview Versico’s VersiWeld TPO reinforced membrane is a premium, heat-weldable, single-ply thermoplastic polyolefin (TPO) sheet designed for new roof construction and re-roofing applications. VersiWeld High Slope (HS) membrane is formulated with additional flame retardant for higher-slope fire code approvals. VersiWeld Plus is 80 mils (2.03 mm) thick for significantly higher strength and weatherability. VersiWeld TPO membranes use advanced polymerization technology that combines the flexibility of ethylene-propylene (EP) rubber with the heat weldability of polypropylene. All VersiWeld TPO membranes include OctaGuard XT™, an industry-leading, state-of-the-art weathering package. OctaGuard XT technology enables VersiWeld TPO to withstand the extreme weatherability testing that is intended to simulate exposure to severe climates. Physical properties of the membrane are enhanced by a strong polyester fabric that is encapsulated between the TPO-based top and bottom plies. The combination of the fabric and TPO plies provides high breaking and tearing strength, as well as excellent puncture resistance. The relatively smooth surface of the membrane produces a total surface fusion weld that results in a consistent, watertight, monolithic roof assembly. The membrane is environmentally friendly and safe to install. BUILDING VALUE TECH N ICAL DATA BULL E TI N White Slate Gray Gray Med Bronze Tan Terra Cotta Patina Green Rock Brown Sustainable Attributes Versico Roofing Systems’ focus has always been innovation – Innovation to solve problems, improve performance, reduce labor, and above all, improve sustainability. Versico is committed to driving sustainable and efficient processes in the design and manufacturing of our products. • Up to 10% pre-consumer recycled content • Fully recyclable when used in mechanically attached systems • 3rd-party verified Environmental Product Declaration available • NSF P151 certification for rainwater catchment** VersiWeld TPO Reinforced Membrane TECH N ICAL DATA BULL E TI N • California Title 24 compliant*** • Free of Living Building Challenge red list chemicals ** White only, produced in Tooele, UT and Carlisle, PA *** White and Tan only Installation VersiWeld TPO roofing systems are quick to install, as minimal labor and few components are required. TPO systems are installed using an Automatic Heat Welder, making sheet welding fast, clean, consistent, and easy to learn, while reducing strain on the roofing technician. Fully-Adhered – membrane is adhered to a suitable substrate utilizing an appropriate bonding adhesive Mechanically Attached – membrane is attached to the roof deck over a suitable substrate utilizing plates and fasteners which are overlapped with membrane Induction-Welded – membrane is attached over a suitable substrate via an induction welding tool being placed over the membrane where a fastened TPO induction welding plate is located to weld the two components together REVIEW CURRENT VERSICO SPECIFICATIONS AND DETAILS FOR SPECIFIC INSTALLATION REQUIREMENTS. Precautions • Sunglasses that filter out ultraviolet light are strongly recommended, as tan and white surfaces are highly reflective. Roofing technicians should dress appropriately and wear sunscreen. • Surfaces may become slippery due to frost and ice buildup. Exercise caution during cold conditions to prevent falls. Exercise caution when walking on wet membrane. Membranes may be slippery when wet. • Care must be exercised when working close to a roof edge when the surrounding area is snow-covered, as the roof edge may not be clearly visible. • Use proper stacking procedures to ensure sufficient stability of the rolls. • Store membrane in the original undisturbed plastic wrap in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. Membrane that has been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot-air welding. • Take care not to stand or place heavy objects on the edge of folded- over membrane, as this could cause a hard crease in the membrane. • Maximum sustained temperature not to exceed 160°F (71°C) for TPO membrane. • Do not use razor blades or other sharp tools to cut the APEEL Protective Film while it is still adhered to the TPO membrane as damage to the underlying membrane may occur. Pull the protective film away from the membrane prior to cutting. BUILDING VALUE Wider is Better Versico’s 16-foot VersiWeld TPO delivers a leap in productivity on adhered and induction welded roofs by cutting down on the number of rolls needed and dramatically reducing the number of seams on the roof. With fewer rolls to load, stage, and kick out, and fewer seams to weld, contractors can save significant time on each project, moving on to the next one sooner. 16-Foot TPO Benefits • Fewer rolls to load and stage on a job saves crane time and labor at the beginning of each project • Fewer rolls to position, kick-out, and align during installation saves labor • Up to 60% fewer seams vs. 10-foot TPO • Fewer seams to weld, probe, and inspect, saving considerable time during installation • Fewer T-joint patches to install on each roof • Less waste and trash from packaging • Less time spent on each project, allowing contractors to complete more roofs and grow their business • Available in High Slope formulation in white and gray colors • Remove APEEL Protective Film by pulling towards the center of the roof. Do not remove the film by pulling towards the roof edge. • A static electric charge may develop when removing APEEL Protective Film from the surface of the membrane sheet. To avoid the possibility of ignition, lids must be closed on any flammable products and a fire extinguisher should be readily available. • Color membranes will ‘fade’ over time mainly due to the ultraviolet portion of sunlight. Since most roof surfaces are exposed to variable sunlight, some areas will be more susceptible to color changes caused by UV fading. Warranties for color membranes do not cover fading of colors. Extreme Testing for Severe Climates ASTM Standard D6878 is the material specification for Thermoplastic Polyolefin-Based Sheet Roofing. It covers material property requirements for TPO roof sheeting and includes initial and aged properties after heat and xenon-arc exposure. As stated in the scope of the standard, “the tests and property limits used to characterize the sheet are values intended to ensure minimum quality for the intended purpose.” Versico’s goal is to produce TPO that delivers maximum performance for the intended purpose of roofing membranes. Maximum performance requires the membrane to far exceed the requirements of ASTM D6878. Heat Aging accelerates the oxidation rate that roughly doubles for each 18°F (10°C) increase in roof membrane temperature. Oxidation (reaction with oxygen) is one of the primary chemical degradation mechanisms of roofing materials. Versico Testing – Heat Aging ASTM Requirement VersiWeld Requirement ASTM Test 240°F 32 weeks** >128 weeks ** Heat exposure comparable to 3,120 weeks (60 years) at 185°F for 8 hours/day. • Test specimen is a 2" by 6" (50.8 mm by 152.4 mm) piece of 45-mil (1.14 mm) membrane unbacked, placed in circulating hot-air oven. • Criterion – no visible cracks after bending aged test specimen around 3" (76.2 mm)-diameter mandrel. Q-Trac testing combines accelerated weathering with real-world conditions using an array of ten mirrors to reflect and concentrate full spectrum sunlight onto membrane test specimens. The Q-Trac device automatically tracks the VersiWeld TPO Reinforced Membrane TECH N ICAL DATA BULL E TI N sun’s path from morning to night. Also, it adjusts to compensate for seasonal changes in the sun’s altitude. Eight years in Q-Trac testing is equal to 40 years of real-world exposure. Versico requires its VersiWeld TPO membranes to pass the equivalent of 40 years of exposure in the Q-Trac. Versico Testing – Q-TRAC ASTM D6878 Requirement VersiWeld Requirements ASTM Test N/A N/A Equivalent of 40 years of exposure Environmental Cycling subjects the membrane to repeated cycles of heat aging, hot-water immersion, and xenon-arc exposure. • ASTM requirement – none • Versico Extreme test*: - 10 days heat aging at 240°F (116°C) followed by BUILDING VALUE Optional APEEL™ Protective Film: Shield Versico’s VersiWeld TPO membrane from dirt and scuffs during installation with APEEL Protective Film. Durable and easy to remove, APEEL eliminates the need for rooftop cleaning upon project completion. • Ideal for re-roofing, re-cover, and new construction projects • Simple and easy to remove • Saves time and money when compared to pressure washing • Protecting from dirt maintains maximum membrane reflectivity and long-term performance Installation Simply order membrane with APEEL, install, and remove the film to reveal a clean, new roof. • APEEL Protective Film should be removed from within areas that are to be heat-welded together. In areas that do not require heat-welding, the APEEL Protective Film can be left in place for up to 90 days without degrading due to its excellent heat- and UV-resistance . • When the installation of the entire TPO roofing system is complete, remove and discard the APEEL Protective Film. VersiWeld TPO Reinforced Membrane TECH N ICAL DATA BULL E TI N BUILDING VALUE Radiative Properties for Cool Roof Rating Council (CRRC) and LEED Test Method White TPO Tan TPO Gray TPO CRRC – Initial solar reflectance ASTM C1549 0.79 0.71 0.46 CRRC – Solar reflectance after 3 years ASTM C1549 (uncleaned) 0.70 0.64 0.43 CRRC – Initial thermal emittance ASTM C1371 0.90 0.86 0.89 CRRC – Thermal emittance after 3 years ASTM C1371 (uncleaned) 0.86 0.87 0.88 LEED – Thermal emittance ASTM E408 0.9 0.86 0.85 SRI – Inital (Solar Reflectance Index) ASTM E1980 99 86 52 SRI – 3 year aged (Solar Reflectance Index) 85 77 49 Radiative Properties (Initial) for Special Colors Reflectance Emittance SRI Medium Bronze 0.28 0.86 29 Rock Brown 0.25 0.87 26 Slate Gray 0.38 0.87 42 Terra Cotta 0.25 0.86 25 Patina Green 0.25 0.88 25 Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI is a measure of the roof’s ability to reject solar heat, as shown by a small temperature rise. It is defined so that a standard black (reflectance 0.05, emittance 0.90) is 0 and a standard white (reflectance 0.80, emittance 0.90) is 100. Materials with the highest SRI values are the coolest choices for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly negative values and particularly cool materials can even exceed 100. Green Building Information Pre-Consumer Recycled Content 10% Post-Consumer Recycled Content 0% Solar Reflectance Index (SRI) White – 99 Tan – 86 Gray – 52 Global Warming Potential (GWP) TPO 45 mils 2.90E+00 TPO 60 mils 3.77E+00 TPO 80 mils 5.28E+00 Volatile Organic Compounds (VOC) Content N/A Manufacturing Location(s) Senatobia, MS Tooele, UT Carlisle, PA Corporate Sustainability Report (CSR) Availability Yes Environmental Product Declaration (EPD) Availability - 5 days water immersion at 158°F (70°C) followed by - 5,040 kJ/m² (2000 hours at 0.70 W/m² irradiance) xenon-arc exposure * Test specimen is 2.75" (69.85 mm by 140 mm) by 5.5" piece of membrane with edges sealed. * Criterion – after 3 complete cycles, test specimens shall remain flexible and not have any cracking under 10x magnification while wrapped around a 3" (76.2 mm)-diameter mandrel. Supplemental Approvals, Statements and Characteristics: 1. VersiWeld TPO meets or exceeds the requirements of ASTM D6878 Standard Specification for Thermoplastic Polyolefin- Based Sheet Roofing. 2. VersiWeld TPO membranes conform to requirements of the US E.P.A. Toxic Leachate Test (40 CFR part 136) performed by an independent analytical laboratory. 3. VersiWeld TPO was tested for dynamic puncture resistance per ASTM D5635-04 using the most recently modified impact head. 45-mil (1.14 mm) was watertight after an impact energy of 12.5 J (9.2 ft-lbf) and 60-mil (1.52 mm) was watertight after 22.5 J (16.6 ft-lbf). 80-mil (2.03 mm) Plus was watertight after an impact energy of 30.0 J (22.1 ft-lbf). 4. All FM approved assemblies have been tested to pass FM 4470 for foot traffic resistance. 8 0 0 .9 9 2.76 6 3 • w w w.ve r s i c o.c o m A S I N G L E S O U R C E F O R S I N G L E - P LY R O O F I N G © 2026 Versico. Printed in U.S.A. VE-2369 - “VersiWeld Reinforced TPO Technical Data Bulletin” - 02.17.26 Versico, VersiWeld, and the Versico logo are trademarks of Versico. APEEL and OctaGuard XT are registered trademarks of Carlisle Construction Materials, LLC. LEED is a registered trademark of the U.S. Green Building Council. VersiWeld TPO Reinforced Membrane TECH N ICAL DATA BULL E TI N Typical Properties and Characteristics Physical Property ASTM D6878 Requirement 45-mil (1.14 mm) 60-mil (1.52 mm) 80-mil Plus (2.03 mm) Tolerance on Nominal Thickness, % ASTM D751 test method +15, -10 ± 10 ± 10 ± 10 Thickness Over Scrim, in. (mm) ASTM D7635 optical method, average of 3 areas 0.015 min (0.380) 0.018 typical (0.457) 0.024 typical (0.610) 0.034 typical (0.864) Breaking Strength, lbf (kN) ASTM D751 grab 220 (976 N) min 225 (1.0) min 320 (1.4) typical 250 (1.1) min 360 (1.6) typical 350 (1.6) min 425 (1.9) typical Elongation Break of Reinforcement, % ASTM D751 grab method 15 min 15 min 25 typical 15 min 25 typical 15 min 25 typical Tearing Strength, lbf (N) ASTM D751 proc. B 8 in. x 8 in. 55 (245) min 55 (245) min 130 (578) typical 55 (245) min 130 (578) typical 55 (245) min 130 (578) typical Brittleness Point, °F (°C) ASTM D2137 -40 (-40) max -40 (-40) max -50 (-46) typical -40 (-40) max -50 (-46) typical -40 (-40) max -50 (-46) typical Linear Dimensional Change, % ASTM D1204, 6 hours at 158°F ± 1 max ± 1 max -0.2 typical ± 1 max -0.2 typical ± 1 max -0.2 typical Ozone Resistance, no cracks 7X ASTM D1149, 100 pphm, 168 hrs PASS PASS PASS PASS UV Exposure (Xenon Arc), no cracks 7X ASTM G155, min. exposure 10,080 kJ/m2 (4,000 hrs – 0.70 W/m2) PASS PASS PASS PASS Water Absorption Resistance, mass % ASTM D471 top surface only 166 hours at 158°F water ± 3.0 max ± 3.0 max 0.90 typical ± 3.0 max 0.90 typical ± 3.0 max 0.90 typical Factory Seam Strength, lbf (N) ASTM D751 grab method 66 (290) min 66 (290) min 66 (290) min 66 (290) min Field Seam Strength, lbf/in (kN/m) ASTM D1876 tested in peel No requirement 25 (4.4) min 50 (8.8) typical 25 (4.4) min 60 (10.5) typical 40 (7.0) min 70 (12.3) typical Water Vapor Permeance, Perms ASTM E96 proc. B No requirement 0.10 max 0.05 typical 0.10 max 0.05 typical 0.10 max 0.05 typical Puncture Resistance, lbf (kN) FTM 101C, method 2031 (see supplemental section) No requirement 250 (1.1) min 325 (1.4) typical 300 (1.3) min 350 (1.6) typical 400 (1.8) min 450 (2.0) typical Properties After Heat Aging ASTM D573, 32 weeks @ 240°F or 8 weeks @ 275°F No cracking when bent around 3" diameter mandrel Weight Change, % PASS No cracking ± 1.5 max PASS No cracking 1.0 max PASS No cracking 1.0 max PASS No cracking 1.0 max Typical Weights lb/ft² (kg/m²) 0.25 (1.22) 0.33 (1.61) 0.45 (2.20) Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. VersiCore® Polyiso Overview VersiCore is a rigid-roof insulation panel composed of a closed-cell polyisocyanurate foam core bonded on each side to glass-reinforced felt (GRF). ReadyFlash® Technology is a standard feature of VersiCore Polyiso that allows the contractor to manipulate flash-off times by choosing which side of the insulation board to apply membrane adhesives. ReadyFlash features a dark glass-reinforced felt (GRF) on one side of the insulation board and a light glass-reinforced felt on the other. • Increases surface temperature of the dark facer up to 25ºF above ambient temperature and provides up to 30% faster adhesive flash-off. • Decreases surface temperature of the light facer up to 5ºF below ambient temperature. Features and Benefits • VersiCore polyiso insulation provides the highest R-value per inch of commercially available insulation products • Zero ozone-depleting components, HFC- and HCFC-free formulation • Approved for direct application to steel decks Panel Characteristics • Available in 4' x 4' (1220 mm x 1220 mm) and 4' x 8' (1220 mm x 2440 mm) panels in thickness of 0.5" (13 mm) to 4.5" (115 mm) • Available in 4' x 12' (1220 mm x 3660 mm) panels in the following thickness: 1.5", 1.75", 2.0", 2.2", 2.5", 2.6", 3.0", 3.3", and 3.5" Applications • Single-Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered) Sustainable Attributes Versico Roofing Systems’ focus has always been innovation – Innovation to solve problems, improve performance, reduce labor, and above all, improve sustainability. Versico is committed to driving sustainable and efficient processes in the design and manufacturing of our products. • Zero ozone-depleting components, HFC- and HCFC-free formulation • CDPH Compliant for maximum allowable concentrations of target VOCs • Up to 56.9% recycled content by weight (36.6% post-consumer/20.3% pre-consumer) • Contributes to LEED® and Green Globes certification requirements • End-of-life jobsite disposal options available for re-use/re-purposing • Versico Polyiso Roof Insulation and HD Cover Board EPDs available • PIMA Quality MarkCM Certification Program participant for Long-Term Thermal R-values (LTTR) • Highest R-value per inch providing maximum energy savings and CO2 emissions avoidance Polyiso Eco Ready (Optional) • 5% bio-content option available (for 2.0" and 2.6" thicknesses) • Contributes to carbon reduction initiatives via mass balance approach under ISCC PLUS compliance Installation Ballasted Single-Ply Systems Each VersiCore panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Versico’s specifications. Mechanically Attached Single-Ply Systems VersiCore panels must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Versico’s specifications. Fully Adhered Single-Ply Systems VersiCore panels must be secured to the roof deck with fasteners and plates (appropriate to deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Versico’s specifications. VersiCore 4' x 8' and 4' x 12' panels can be secured to the roof deck with Versico’s Flexible DASH™ Adhesive, either full coverage or bead spacing. VersiCore 4' x 4' panels may be adhered to prepared concrete deck with a full mopping of Type III or IV asphalt. REVIEW CURRENT VERSICO SPECIFICATIONS AND DETAILS FOR SPECIFIC INSTALLATION REQUIREMENTS. BUILDING VALUE TECH N ICAL DATA BULL E TI N 8 0 0 .9 9 2.76 6 3 • w w w.ve r s i c o.c o m A S I N G L E S O U R C E F O R S I N G L E - P LY R O O F I N G © 2025 Versico. Printed in U.S.A. VE-8756 - “VersiCore Polyiso Technical Data Bulletin” - 10.27.25 US PATENT NUMBER: 10,662,652 Versico, VersiCore, DASH, and the Versico logo are trademarks of Versico. ReadyFlash is a trademark of Carlisle Construction Materials, LLC. LEED is a registered trademark of the U.S. Green Building Council. VersiCore Polyiso TECH N ICAL DATA BULL E TI N Foamed plastic as roof deck construction material with resistance to an internal fire exposure only for use in construction no.(s) 120 and 123. See UL Directory of Products Certified for Canada and UL Roofing Materials and Systems Directory. 99DL. Typical Properties and Characteristics Physical Property Test Method Value Compressive Strength ASTM D1621 20 psi* minimum (138 kPa, Grade 2) Dimensional Stability ASTM D2126 2% linear change (7 days) Moisture Vapor Permeance ASTM E96 <1 perm (57.5 ng/(Pa•s•m²)) Water Absorption C1763 <1% volume Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. *Also available in 25 psi minimum, Grade 3 VersiCore Polyiso Thermal Values Thickness (inches) LTTR R-value Thickness (inches) LTTR R-value 0.5 2.8 2.75 15.9 0.75 4.2 2.8 16.2 1 5.7 2.9 16.8 1.1 6.3 *3 17.4 1.2 6.8 3.1 18 1.25 7.1 3.2 18.6 1.3 7.4 3.25 18.9 1.4 8 *3.3 19.2 *1.5 8.6 3.4 19.9 1.6 9.1 *3.5 20.5 1.7 9.7 3.6 21.1 *1.75 10 3.7 21.7 1.8 10.3 3.75 22 1.9 10.8 3.8 22.3 *2 11.4 3.9 23 2.1 12 4 23.6 *2.2 12.6 4.1 24.2 2.25 12.9 4.2 24.9 2.3 13.2 4.25 25.2 2.4 13.8 4.3 25.5 *2.5 14.4 4.4 26.1 *2.6 15 4.5 26.8 2.7 15.6 – – Flute Spanability is 2 5⁄8" for 1.4" or thickness or smaller. Flute Spanability is 4 3⁄8" for 1.5" thickness or greater. *4' x 12' offering is available in this thickness. Codes and Compliances • ASTM C1289, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi) • International Building Code (IBC) Section 2603 • UL Standard 790, 263 and 1256: Component of Class A Roof Systems (refer to UL Roof Materials’ system directory) • FM® Standards 4450/4470: Class 1 approval for steel roof-deck constructions (refer to FM RoofNavSM) • California Code of Regulations, Title 24, Insulation Quality Standard License #TI-1418 • Third-party certification with the PIMA QualityMarkCM for Long-Term Thermal Resistance (LTTR) values • CAN/ULC S704, Type 2, Class 3 (20 psi), Type 3, Class 3 (25 psi) • Florida Building Code Approval • CDPH compliant for maximum allowable concentrations of target VOCs Precautions Insulation must be protected from open flame and kept dry at all times. Install only as much insulation as can be covered the same day by completed roof-covering material. Protect installed product from excessive foot traffic. Versico will not be responsible for specific building and roof design by others, for deficiencies in construction or workmanship, for dangerous conditions on the job site or for improper storage and handling. Technical specifications shown in this literature are intended to be used as general guidelines only and are subject to change without notice. Call Versico for more specific details, or refer to PIMA Technical Bulletin No. 109: Storage & Handling Recommendations for Polyiso Roof Insulation.