1114 Hickox St., Suite A Santa Fe, NM 87505 505.820.1555Design Standards & Signage Exceptions 2026-013419-HDRB – Main House. 616 Acequia Madre. Downtown & Eastside Historic District. Significant. Woven Architecture, agent for Jusbasche Investments Ltd., owner, proposes to demolish the sauna and changing room, construct a 150 sq. ft. portal addition to a height of 10’-6” where the existing height is 12’-4”, infill windows and doors, install a new bay window, stucco, and replace patio paving on the main residence. EXCEPTIONS BEING REQUESTED (7 total): 1) 14-4.6(E)(4)(I)(a) removing openings on a primary façade: a. North Façade – proposed infill of existing door/transom opening at enclosed sleeping porch. b. West Façade – proposed infill of existing window openings at enclosed sleeping porch c. South Façade – proposed removal of existing window opening at proposed portal location. 2) 14-4.6(E)(4)(II) removing historic material: a. Southeast corner – proposed demolition of sauna and changing rooms added in the 1980’s. b. South Façade – removal of (non)historic material for addition of a window at enclosed sleeping porch. 3) 14-4.6(E)(2)(II)(a) addition to primary façade: a. East Façade – proposed portal b. South Façade – proposed bay window QUESTIONS to be answered for the exceptions being requested: A. The requested change does not damage the character of the district. B. The requested change is/are required to prevent a hardship to the applicant or an injury to the public welfare. C. The requested change is required [or will] strengthen the unique heterogeneous character of the City by providing a full range of design options to ensure that residence can continue to reside within the historic districts. RESPONSES: Each exception requested is answered within the individual questions (A, B, and C). In all cases, except the demolition of the sauna and changing rooms, all proposed changes have the ability to be reversed in the future without damaging the character of the district, preventing a hardship to future applicants or injury to the public welfare, and without compromising the full range of design options that would allow residents to continue to reside in this historic district. A. The requested change does not damage the character of the district. 1) 14-4.6(E)(4)(I)(a) Removing Openings on a Primary Façade: a. North Façade – Proposed Infill of Existing Door and Transom at Enclosed Sleeping Porch. Allowing this exception does not damage the character of the district for these reasons: Removal of this door and transom opening will not affect the district in any way, as it will not alter the character of this historic structure, its style, size, or historic significance. The door and transom in question are not original. Exhibit A, at the end of this document, is a photo from 1974 which shows a different door assembly, indicating the existing door and transom was installed after 1974, though it is unknown when. As the infill will be slightly recessed to show the memory of a previous opening, the integrity of the original building primary façade will be maintained. Further, the character of this district is defined by low-profile residential buildings, of Old or Recent Santa Fe Style, which are inclusive of Pueblo Revival and Spanish Territorial examples of architecture. This structure is one of the finest examples of Spanish Territorial 616 Acequia Madre – Main House Exception Criteria :: Case #2026-013419 HDRB October 27, 2026 :: Page 2 of 7 architecture in the Downtown and Eastside Historic District and removal of this opening will not in any way change the building’s overall architectural integrity, therefore this exception will not damage the character of the district. b. West façade – Infill of Existing Window Openings at Enclosed Sleeping Porch. Allowing this exception does not damage the character of the district because, similar to (a) above, the overall integrity, scale, style, and detailing of this historic building will remain the same. This minor change to the west façade is not out of character with the scale, style, and materials that define this district. Furthermore, the design of the windows in question could be seen as more out of character for this district, as they are undivided large panes of glass, not typically found in the Downtown & Eastside District. In addition, as shown in Exhibit B, at the end of this document, there is precedent for removal of windows and infill with stucco at the sleeping porch. The photo of the south shows where windows at this room were previously infilled (one can see the original windows in Exhibit A; date of construction unknown). This façade is not visible from the public right-of-way, so the proposed infill of these windows will not damage the character of the district. c. South Façade – Removal of Existing Window Opening at Proposed Portal Location. Allowing this exception does not damage the character of the district because, similar to (a) and (b) above, the overall integrity, scale, style, and detailing of this historic building will remain the same. This minor change, proposed at the southeast corner of the structure, will allow for the addition of a door in the same location, albeit in a slightly larger opening, for accessible access for the building’s occupants. The removal of the window and widening of the opening and is not out of character with the scale, style, and materials that define this district – and will allow other narrow exterior openings to remain. This façade is not visible from the public right-of-way, so the removal of this window will not damage the character of the district. 2) 14-4.6(E)(4)(II) Removing Historic Material: a. Southeast Corner – Proposed Demolition of Sauna & Changing Rooms added in the 1980’s. This exception to allow for removal of historic material will not damage the character of the district because the overall character, scale, and style of this historic building will remain unchanged. This portion of the building is non-historic as it was added to the building in the 1980’s. Walls are stucco and wood siding, with a mix of brick parapet and wood shingled roof, it has no character-defining features – and is out of scale with the rest of the structure. According to a HCPI form survey, dated 02/09/2026, the addition was added for a pool which is long gone, as was described as “the associated pool-changing rooms and sauna are still attached at the southeast corner of the house and add no real value to the property or history.” The removal of this non-historic addition will enhance the historic massing and fabric of this significant structure; therefore, this change will not impact the character of the district. b. Southwest corner – Removal of Portion of Stucco Infill Wall at South Façade of Sleeping Porch for a New Window. As it is unknown when the stucco infill on the south façade of the sleeping porch occurred, it is unclear if the infill is historic. Allowing for the removal of a portion of the one of the infill for a small window will not damage the character of the district because the overall character, scale, and style of this historic structure will remain unchanged. Not visible to the public right-of-way, removal of this material will not impact the character of the district. 3) 14-4.6(E)(2)(II)(a) Addition to a Primary Facade: a. East Façade – Proposed Portal Allowing this exception to add a portal to a primary façade will not damage the character of the district for the following reasons. One of the most common architectural features that define the architecture and style of the Downtown & Eastside District is portals, in both Pueblo Revival and Spanish Territorial buildings. There is already an existing door opening at this portion of structure on the east façade, though too narrow for an accessible entry, and adding 616 Acequia Madre – Main House Exception Criteria :: Case #2026-013419 HDRB October 27, 2026 :: Page 3 of 7 a portal is completely within the architectural vocabulary of the district. Also, no character- defining features of the façade will be removed or concealed by this proposed addition (existing zig-zag wood canales will remain above the roof). The scale of the proposed portal fits well within the framework of the façade, and its height is lower than that of the existing building, allowing for differentiation between “old” and “new.” Further, this façade (even though considered primary) is not visible from any public right-of-way, and is in fact tucked back behind the structure and hidden by the old garage/carriage house on the east. Therefore, the district’s character will remain intact and undamaged. b. South Façade – Proposed Bay Window Allowing this exception for the addition of a bay window on the south façade will not damage the character of this historic district. There is precedent for an angled corner on this building as evidenced by the existing angled wall with a window on the east façade, just south of the kitchen entry (see Exhibit C). Already a feature of this residence, the angled wall is a method traditionally used to bring more daylight into an interior space – capturing light from the southeast and southwest, in this case. This addition fits within an existing opening that has a non-historic window. The scale of the proposed bay window fits within the façade, it has a sloped roof, and it’s height is lower than that of the existing brick parapet, and below the existing canale, thus differentiating this proposed change between “old” and “new” construction. The south façade is not publicly visible; therefore, the district’s character will remain intact and will not be damaged by this addition. B. Exception Required to Prevent a Hardship to the Applicant or an Injury to the Public Welfare. 1) 14-4.6(E)(4)(I)(a) Removing Openings on a Primary Façade: a. North Façade – Proposed Infill of Existing Door and Transom at Enclosed Sleeping Porch. Granting this exception would prevent a hardship to the applicant. The original configuration and use of this room was a sleeping porch, which was later enclosed with windows. The current occupant will not be using this room as a sleeping porch and intends to use it as a bathroom and closet. The door will not be used in this new configuration and creates opportunities for moisture and pest intrusion and is poorly insulated. An abandoned door also creates ongoing maintenance issues that are a hardship. b. West façade – Infill of Existing Window Openings at Enclosed Sleeping Porch. This exception would prevent the following hardship to the applicant – the windows on the west façade are poorly insulated and the room enclosed by them does not have a good seal and envelope. The proposed new use of this room as a bathroom and closet requires good moisture resistance and vapor protection, which cannot be achieved by leaving these windows in place. c. South Façade – Removal of Existing Window Opening at Proposed Portal Location. This exception prevents the following hardship to the applicant – the room where this window is located has no access to the exterior. Access and connection to the beautiful gardens and outdoor space is very important to the applicant and not allowing this conversion of window to a double door would limit the applicant’s options for full use of the property and limit their ability to successfully adapt this building to make it perform per today’s standards of energy, light, fresh air, and accessibility. The main entry to the house on the north façade does not have an accessible path (and the applicant would prefer to not add a ramp at the main historic entry). Other existing, historic exterior doors are too narrow for a wheelchair. Applying the design standards without exception creates a hardship by unduly restricting the adaptation of this 100-year old structure to its modern day use. It is extremely difficult, if not impossible, to take a building of this age and rehabilitate it to make it a livable space, meeting current codes and standards, without making any changes to the exterior. 616 Acequia Madre – Main House Exception Criteria :: Case #2026-013419 HDRB October 27, 2026 :: Page 4 of 7 2) 14-4.6(E)(4)(II) Removing Historic Material: a. Southeast Corner – Proposed Demolition of Sauna & Changing Rooms added in the 1980’s. An exception to the design standards would prevent the following hardship to the applicant – the sauna and changing rooms were designed and built strictly for that use. Their size, dimensions, and shape make them difficult to adapt for other uses – certainly not for habitable rooms. Also, the sauna was built of wood planks, and does not have proper insulation, mechanical, plumbing, or electrical systems. These rooms were not connected to the house via the interior, as this was an addition meant for exterior use only, as an accessory to the pool, which was demolished many years ago. It is a hardship to leave these rooms in place, as they are not usable and not adaptable. Their addition in the 80’s was not planned well and did not integrate into the history and architecture of this significant building. b. Southwest Corner – Removal of Portion of Stucco Infill Wall at South Façade of Sleeping Porch for a New Window. An exception to removing a portion of the infill wall at the old sleeping porch for a new window prevents a hardship for the occupant by allowing them the ability to view the yard and gardens surrounding this significant structure from the southeast corner of the old sleeping porch. Built in the 1930’s the idea of a sleeping porch is no longer relevant to today’s use due to the invention of air conditioning. 3) 14-4.6(E)(2)(II)(a) Addition to a Primary Facade: a. East Façade – Proposed Portal Applying the design standards without exception creates the following hardship to the applicant – the only existing entry into the house with a historic door that is 36” or wider and provides shelter from the elements, is the main entry on the north façade. Only accessible via brick steps, the main entry is not in proximity to the old garage/carriage house and parking area, making it hard to park a car in inclement weather, without having to walk through snow or ice-covered path or being soaked by rain, creating an undue hardship to the occupants. While there are two historic doors on the east façade, neither is wide enough to accommodate a wheelchair. The proposed location of this portal is closer to the parking area and old garage/carriage house, thus providing a better solution for a covered accessible entry that reduces the impact to historic doors, thus preserving the historic integrity of the existing building and site. Allowing this exception would prevent a hardship by allowing the applicant to create an accessible path from the parking area/garage to an entry point of the residence, while providing safety, shelter, and reducing the potential risk of injury that may occur with a longer path. As previously stated, it is extremely difficult, if not impossible, to take a building of this age and rehabilitate it to make it a livable space, meeting current codes and standards, without making any changes to the exterior. b. South Façade – proposed bay window Granting this exception to add this proposed bay window to a primary façade would prevent the following hardship to the applicant – the size of the rooms in this residence are based on a standard that is more than 100-years old. While this bedroom may have served well and fit furniture comfortably back then, by today’s standards, this room offers limited space for a full set of bedroom furniture. The size of this room is further affected by the existing layout of the corridor and circulation. This room serves as the access point to the study and corridor, so about a quarter of the room area is taken up by circulation and not available for furniture placement. It is very challenging to adapt a building of this age without any modifications to the exterior, limiting the design options and functionality of the spaces. Allowing this exception would prevent this hardship to the applicant and would also allow this building to be adapted to the continued use of a residence that meets today’s standards, while still retaining its integrity. Adding this proposed bay window on a facade that is not publicly visible will prevent the above hardship to the applicant and have no negative impact on the architecture, scale, style, or history of the building. 616 Acequia Madre – Main House Exception Criteria :: Case #2026-013419 HDRB October 27, 2026 :: Page 5 of 7 C) Exception will strengthen the unique heterogeneous character of the City by providing a full range of design options to ensure that residents can continue to reside within the Historic Districts. 1) 14-4.6(E)(4)(I)(a) Removing Openings on a Primary Façade: a. North Façade – Proposed Infill of Existing Door and Transom at Enclosed Sleeping Porch. b. West façade – Infill of Existing Window Openings at Enclosed Sleeping Porch. c. South Façade – Removal of Existing Window Opening at Proposed Portal Location. Granting this exception will strengthen the unique heterogeneous character of the City by allowing this significant building to be successfully adapted for its new owner and continued use as a beloved residence, therefore ensuring that the building will be maintained and inhabited, rather than sit vacant and deteriorate. This exception will provides a design option that ensures that the building can be adapted to fit the needs of its new residents and will allow them to successfully continue to reside within this historic district. 2) 14-4.6(E)(4)(II) Removing Historic Material: a. Southeast Corner – Proposed Demolition of Sauna & Changing Rooms added in the 1980’s Granting this exception will strengthen the unique heterogeneous character of the City by allowing this significant building to be successfully adapted for its new owner and new use, therefore ensuring that the building will be maintained and inhabited, rather than sit vacant and deteriorate. Allowing the demolition of this non-historic addition to the building will improve the overall integrity of this historic structure as it will remove an addition that detracts from the significance of the building. The sauna and changing rooms were designed and constructed as utilitarian spaces and add no value to the overall architecture and history of this property. This exception will provide a design option that ensures that the building can be adapted to fit the needs of its new residents and will allow them to successfully continue to reside in within the Downtown and Eastside Historic District. b. Southwest Corner – Removal of Portion of Stucco Infill Wall at South Façade of Sleeping Porch for a New Window. Granting the exception to removal of potential historic wall material will allow the applicant to continue to use the residence in a manner that meets today’s residential standards. Not visible from the public right-of-way, the addition of a small window fits within the full range of design options, thus allowing for residents to continue to reside within the historic district. 3) 14-4.6(E)(2)(II)(a) Addition to a Primary Facade: a. East Façade – Proposed Portal Granting this exception will strengthen the unique heterogeneous character of the City by allowing this significant building to be successfully adapted for its new owner and continued use, therefore ensuring that the building will be maintained and inhabited, rather than sit vacant and deteriorate. By allowing this portal to be added to a primary façade, the accessibility and safety of the residence is improved. Having improved accessibility and safety is a key factor to ensuring residents can continue to reside in the Historic District and age in place. A portal over an entry area is one of the most common elements in the architecture of this district, and also one of the best ways to add shelter, safety, and a sense of welcoming to a residence. This is the best way to ensure that residents can continue to reside in the Downtown and Eastside Historic District. b. South Façade – Proposed Bay Window Granting this exception will strengthen the unique heterogeneous character of the City by allowing this significant building to be successfully adapted for the applicant and the building’s continued use as a residence, therefore ensuring that the building will be inhabited, maintained, and will not become vacant and deteriorate. This exception will certainly provide a design option that ensures that the building can be adapted to fit the needs of its new residents and will allow them to successfully continue to reside within this historic district. Applying the 616 Acequia Madre – Main House Exception Criteria :: Case #2026-013419 HDRB October 27, 2026 :: Page 6 of 7 Design Standards without exception creates an inflexible and challenging environment for the owners of properties in the historic districts, which in turn discourages people from buying properties or residing in these districts. The only way to encourage residents to continue residing in the historic districts is to allow for some flexibility and adaptability of historic structures, while still succeeding in historic preservation, rehabilitation, restoration, or adaptive reuse. Exhibit A Photo of enclosed porch, taken 1974, showing no transom and a different door assembly than the current condition. 616 Acequia Madre – Main House Exception Criteria :: Case #2026-013419 HDRB October 27, 2026 :: Page 7 of 7 Exhibit B Existing condition at south façade of enclosed sleeping porch shows precedent of two window openings which have been infilled. Exhibit C Existing condition at east façade with angled wall and window 616 Acequia Madre House – Existing Conditions (Main House) Page 1 of 8 1. North Façade (Main Entry) 2. East Façade (Kitchen Entry) 616 Acequia Madre House – Existing Conditions (Main House) Page 2 of 8 3. West Façade (at Bedrooms where New Portal is Proposed) 4. Southeast Corner (View of Sauna & Changing Rooms) 616 Acequia Madre House – Existing Conditions (Main House) Page 3 of 8 5. South Façade – East Side (Sauna & Changing Rooms at Right) 6. South Façade – Midde & West Side (Sun Room slightly visible behind large tree at right) 616 Acequia Madre House – Existing Conditions (Main House) Page 4 of 8 7. South Façade – Looking East towards Sun Room and Changing Rooms 8. South Façade – Looking East (at West Façade of Sun Room) 616 Acequia Madre House – Existing Conditions (Main House) Page 5 of 8 9. South Façade – SW Corner (non-historic window at right; existing stucco infill at Sleeping Porch) 10. West Façade – SW Corner showing Old Sleeping Porch (Sun Room is visible beyond) 616 Acequia Madre House – Existing Conditions (Main House) Page 6 of 8 11. West Façade – Looking at North End from within Garden 12. North Façade of Old Sleeping Porch (Door) 616 Acequia Madre House – Existing Conditions (Main House) Page 7 of 8 13. Northeast Corner 14. Front Entry Porch (Note: stucco is slightly proud of existing brick parapet – typical) 616 Acequia Madre House – Existing Conditions (Main House) Page 8 of 8 15. Northeast Corner of Kitchen Entry (Note: Contra Paredes visible at base of conduit) 616 Acequia Madre House PROPOSED FINISHES Stucco Color #1 (Field) – All Structures: Sto, Cementitious Torreon #1501MAIN HOUSE 616 Acequia Madre House PROPOSED FINISHES Stucco Color #2 (Accent) – All Structures: Sto, Cementitious Marble White 01008 616 Acequia Madre House PROPOSED FINISHES Stain (All Structures): Dunn Edwards Enchanting Ivy, #DEA179 616 Acequia Madre House PROPOSED FINISHES Paint (White Trim – All Structures): Sherwin Williams High Reflective White #SW7757 616 Acequia Madre House PROPOSED FINISHES Paint (Shutters) – Main House only: Dunn Edwards Enchanting Ivy, #DEA179 DN EP 3R @ 4" :: 2T @ 16" DN DN MAIN HOUSE GARDEN CARRIAGE HOUSE A1 SITE PLAN - EXISTING 1" = 20'-0" PLAN NORTH 0' 10' 20' 40' HAS-101 EXISTING SITE PLAN 25010 HAS-101 SITE (HDRB) BJF BJF 06/15/26 HDRB 10/08/26 HDRB SHEET SIZE: 36 x 48 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. MARK DATE DESCRIPTION I S S U E D PROJECT NO. FILE NAME DRAWN BY CHECKED BY S h e e t N a m e S h e e t N o . SHEET NO. OF SHEETS 7654321 A B C D E F JUSBASCHE RESIDENCE 616 ACEQUIA MADRE SANTA FE, NM 87501 HISTORIC DESIGN REVIEW BOARD NOT FOR CONSTRUCTIONMAIN HOUSE EP 4R @ 5" :: 3T @ 16" DN DN SHELF MAIN HOUSE GARDEN CARRIAGE HOUSE A1 SITE PLAN - PROPOSED 1" = 20'-0" PLAN NORTH 0' 10' 20' 40' HAS-102 PROPOSED SITE PLAN 25010 HAS-102 SITE (HDRB) BJF BJF 06/15/26 HDRB 10/08/26 HDRB SHEET SIZE: 36X48 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. MARK DATE DESCRIPTION I S S U E D PROJECT NO. FILE NAME DRAWN BY CHECKED BY S h e e t N a m e S h e e t N o . SHEET NO. OF SHEETS 7654321 A B C D E F JUSBASCHE RESIDENCE 616 ACEQUIA MADRE SANTA FE, NM 87501 HISTORIC DESIGN REVIEW BOARD NOT FOR CONSTRUCTION SQUARE FOOTAGE (HEATED): EXISTING DEMO NEW TOTAL MAIN HOUSE 5,412 -140 23 5,295 CARRIAGE HOUSE 1,780 0 85 1,865 SHED / BARN 232 0 0 232 TOTAL COVERED 7,424 -140 108 7,392 SQUARE FOOTAGE (ROOFED): EXISTING DEMO NEW TOTAL MAIN HOUSE 5,550 -140 150 5,560 CARRIAGE HOUSE 2,051 0 85 2,136 SHED / BARN 232 0 0 230 TOTAL COVERED 7833 -140 235 7,928MAIN HOUSENEW DOOR @ EXISTING WINDOW OPENINGNEW PORTALNEW VIGA ENDS (3)NEW BAY WINDOWNEW SHOWER WINDOWNEW INFILL WALL AT DOOR & TRANSOMNEW INFILL WALL WINDOWS BETWEEN WOOD TRIM 71'-212" 5'-1"12'-812"31'-412"21'-512" 10'-11" 105'-1012" SEWING ROOM BEDROOM BEDROOM BATHROOM SOUTH ENTRY HALL SUNROOM STUDY LIVING ROOM DINING ROOM KITCHEN KITCHEN ENTRY KITCHEN BATH PANTRY CLOSET CLOSET MASTER BATH CLOSET SUNROOM BATHROOM ROOF (SKYLIGHT ABOVE) STORAGE CENTRAL HALL CLOSET FRONT ENTRY CLOSET EAST HALL BASEMENT CLOSETCLOSET MASTER BEDROOM DN EP 3R @ 4" :: 2T @ 16" DN 103'-512" 22'-6" 7'-4" CHANGING RM SAUNA ELEC + STOR B1 HMA-201 A1 HMA-202 C1 HMA-201 C1 HMA-202 ACCESS TO CRAWL SPACE ACCESS TO CRAWL SPACE BASEMENT WINDOW WELL EXISTING SLOPED PORTION OF FLAGSTONE TO GRADE , TO BE REMOVED AT GRADE SAUNA, STORAGE & CHANGING ROOM NO LONGER IN USE (THERE IS NO LONGER A POOL ON SITE) REMOVE EXISTING WINDOW AND INFILL OPENING EXISTING WINDOW TO BE DEMOLISHED EXISTING STRUCTURE, INCLUDING WALLS, ROOF, AND FOUNDATIONS TO BE DMEOLISHED EXISTING WINDOW AND PORTION OF WALL BELOW TO BE DEMOLISHED FOR NEW DOOR OPENING PORTION OF EXISTING WALL TO BE REMOVED FOR NEW DOOR OPENING REMOVE EXISTING DOUBLE DOOR AND INFILL OPENING REMOVE EXISTING WINDOW AND INFILL OPENING REMOVE PORTION OF EXISTING WALL FOR NEW WINDOW OPENING EXISTING PARTIAL HEIGHT WALL 6'-4" EXISTING FLAGSTONE TO BE REMOVED EXISTING BRICK PABVERS TO BE REMOVED EXISTING WALLS (ADOBE OR FRAME) NEW WALLS EXISTING WALL/ELEMENT TO BE DEMOLISHED A1 MAIN HOUSE - EXISTING FLOOR PLAN 1/4" = 1'-0" 0' 2' 4' 8' All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. MARK DATE DESCRIPTION I S S U E D PROJECT NO. FILE NAME DRAWN BY CHECKED BY S h e e t N a m e S h e e t N o . SHEET NO. OF SHEETS 7654321 A B C D E F JUSBASCHE RESIDENCE 616 ACEQUIA MADRE SANTA FE, NM 87501 HISTORIC DESIGN REVIEW BOARD NOT FOR CONSTRUCTION HMA-101 MAIN HOUSE EXISTING FLOOR PLAN 25010 HMA-101 PLAN (HDRB) BJF, TD BJF 06/15/26 HDRB 10/08/26 HDRB PLAN NORTH 1. ALL DIMENSIONS ARE APPROXIMATE BASED ON EXISTING FIELD CONDITIONS LEGEND & NOTES SHEET SIZE: 36 x 48 DN EP 3R @ 4" :: 2T @ 16" DN DN BEDROOM 2 MASTER BEDROOM STUDY LIVING ROOM DINING ROOM KITCHEN KITCHEN ENTRY CLOSET BATH 3 CENTRAL HALL FRONT ENTRY PANTRY EAST HALL CLOSET 2 BATH 2 BEDROOM 4 BATH 4 BEDROOM 3SUNROOM & KID'S ROOM CLOSET 3 CLOSET BATHROOM HALL HALL POWDER CLOSET 4 18'-712" 8'-1" 11'-1" 2'-712" PROPOSED BAY WINDOW W/ CONCRETE SILL (NEW WALL BELOW); + 23 SF NEW WINDOW IN EXISTING WALL INFILL EXISTING WINDOW OPENING (SIM. TO EXISTING INFILL AT SOUTH FACADE) INFILL EXISTING DOOR OPENING (RECESS WALL TO RETAIN HISTORY OF OPENING) PROPOSED DOUBLE DOORS IN PLACE OF EXISTING WINDOW (WIDEN OPENING) NEW BRICK PAVING REPAIR OR REPLACE BRICK AT EXISTING PARTIAL HEIGHT WALL TOP NEW WOOD GUARDRAIL, PAINTED A1 HMA-201 D1 HMA-201 D1 HMA-202 B1 HMA-202 NEW BRICK PAVING REPAIR OR REPLACE IN KIND ROTTEN WINDOW & DOOR BUCKS AS NEEDED (TYP). NEW CEMENTITIOUS STUCCO AT ADOBE WALLS WHERE EXISTING STUCCO IS DELAMINATING (TYP,) REPAIR ADOBE BEHIND STUCCO AT AREA WHERE STUCCO IS DELAMINATING FROM WALLS (AS NEEDED); TYP. REPAIR OR REPLACE CRACKED OR FAILING CONRETE WINDOW SILLS WITH NEW CONCRETE TO MATCH EXISTING SHAPE & SIZE (TYP). REBUILD WARPED & ROTTEN WOOD WINDOW SCREENS; MATCH EXISTING DIMENSIONS & MATERIALS (TYP). ** Note: All windows have screens even if they are currently missing. REPAIR EXISTING WOOD TRIM, INCLUDING RAIL BELOW WINDOWS (TYP). REPAIR EXISTING WOOD TRIM, INCLUDING PANELS BELOW WINDOWS (TYP). NEW BRICK STAIRS (TO BE FINALIZED W/ LANDSCAPE PLAN) PROPOSED ADDITION PROPOSED ADDITION 3'-512" PROPOSED PORTAL PROPOSED ADDITION PROPOSED WOOD POSTS, STAINED 4'-312" 106'-0" 71'-212" PROPOSED BRICK PAVERS AT PORTAL EXISTING WALLS (ADOBE OR FRAME) NEW WALLS EXISTING PROPOSED HEATED 5,413 5,296 UNHEATED 0 0 SUB-TOTAL 5,413 5,296 PORTAL FRONT 142 142 REAR 0 150 SUB-TOTAL 142 292 A1 MAIN HOUSE - PROPOSED FLOOR PLAN 1/4" = 1'-0" 0' 2' 4' 8' All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. MARK DATE DESCRIPTION I S S U E D PROJECT NO. FILE NAME DRAWN BY CHECKED BY S h e e t N a m e S h e e t N o . SHEET NO. OF SHEETS 7654321 A B C D E F JUSBASCHE RESIDENCE 616 ACEQUIA MADRE SANTA FE, NM 87501 HISTORIC DESIGN REVIEW BOARD NOT FOR CONSTRUCTION HMA-102 MAIN HOUSE PROPOSED FLOOR PLAN 25010 HMA-102 PLAN (HDRB) BJF, TD BJF 06/15/26 HDRB 108/08/26 HDRB PLAN NORTH 1. ALL DIMENSIONS ARE APPROXIMATE BASED ON EXISTING FIELD CONDITIONS LEGEND & NOTES SHEET SIZE: 36 x 48 BUILDING AREAS ELEC. PANEL REPAIR BASE OF WALL FROM REMOVAL OF CONTRA PARADES @ BASE OF WALLS ( TYP. ) 12'-4" TOP OF PARAPET REPAIR ADOBE BEHIND STUCCO WHERE STUCCO IS DELAMINATING FROM WALLS (TYP. ) 0'-0" FINISH FLOOR NEW CEMENTITIOUS STUCCO @ ADOBE WALL REPAIR ROTTEN BUCKS AND WINDOWS & DOORS AS NEEDED (TYP.) 12'-4" EXISTING GRADE PORTAL ADDITION NEW STAINED WOOD POSTS & BEAMS BRICK COPING WITH METAL CAP 3'-6" 10'-6" 1'-10" PATCH & REPAIR AREAS OF STUCCO DAMAGE 10'-10" 8'-5" STUCCO (BROWN/TAN TO MATCH EXISTING ) 12'-4" TOP OF PARAPET 12'-3" TOP OF PARAPET 12'-4" TOP OF PARAPET 0'-0" FINISH FLOOR 13'-10" TOP OF PARAPET PROPOSED INFILL OF EXISTING OPENING, INSET TO SHOW HISTORY OF OPENING NEW STUCCO EXISTING BRICK STEPS NEW STUCCO ( INSET: WHITE,TO MATCH EXISTING ) NEW STUCCO (BROWN/TAN) TO MATCH EXISTING 15'-1" MAX. BLDG. HEIGHT (EXISTING) EXISTING GRADE NEW STAIN, COLOR TO MATCH EXISTING ELEC. PANEL 10'-10" KITCHEN ENTRY 8'-3" 8'-8" 9'-2" 12'-4" TOP OF PARAPET 0'-0" FINISH FLOOR EXAMPLE OF CONTRA PEREDESREMOVE EXISTING METAL DOWNSPOUT EXISTING SHED TO BE DEMOLISHED LINE OF BEAM BEARING HT. 10'-10" 8'-7" 12'-4" TOP OF PARAPET 8'-3" BEAM BEARING 0'-0" FINISH FLOOR EXISTING METAL CAP/FLASHING 13'-10" TOP OF PARAPET EXISTING BRICK STEPS 15'-1" MAX. BLDG. HEIGHT (EXISTING) EXISTING GRADE EXISTING GRADE REMOVE EXISTING DOUBLE DOOR AND INFILL OPENING REMOVE EXISTING TRANSOM AND INFILL OPENING BEAM BEARING HT. EXISTING METAL GRILLES TO BE REMOVED A1 MAIN HOUSE - PROPOSED EXTERIOR ELEVATION - EAST 1/4" = 1'-0" 0' 2' 4' 8' All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. MARK DATE DESCRIPTION I S S U E D PROJECT NO. FILE NAME DRAWN BY CHECKED BY S h e e t N a m e S h e e t N o . SHEET NO. OF SHEETS 7654321 A B C D E F JUSBASCHE RESIDENCE 616 ACEQUIA MADRE SANTA FE, NM 87501 HISTORIC DESIGN REVIEW BOARD NOT FOR CONSTRUCTION D1 MAIN HOUSE - PROPOSED EXTERIOR ELEVATION - NORTH 1/4" = 1'-0" 0' 2' 4' 8' B1 MAIN HOUSE - EXISTING EXTERIOR ELEVATION - EAST 1/4" = 1'-0" 0' 2' 4' 8' E1 MAIN HOUSE - EXISTING EXTERIOR ELEVATION - NORTH 1/4" = 1'-0" 0' 2' 4' 8' HMA-201 MAIN HOUSE EXISTING & PROPOSED EXTERIOR ELEVATIONS (NORTH & EAST) 25010 HMA-201-ELEV (HDRB) BJF, AB BJF 06/15/26 HDRB 10/08/26 HDRB 13'-10" TOP OF PARAPET 12'-4" TOP OF PARAPET 0'-0" FINISH FLOOR EXISTING SHED TO BE DEMOLISHED EXISTING WINDOW TO BE REMOVED 9'-3" 8'-8" 9'-6" 12'-3" 12'-4" TOP OF PARAPET 10'-5" TOP OF PARAPET 0'-0" FINISH FLOOR LINE OF BEAM BEARING HT. RELOCATE EXISTING DOWNSPOUT EXISTING WINDOW AND WALL BELOW SILL TO BE REMOVED FOR NEW BAY WINDOW OPENING REMOVE PORTION OF EXISTING WALL FOR NEW WINDOW OPENING EXISTING SAUNA & SHED TO BE DEMOLISHED 11'-1112" EXISTING WINDOW AND PORTION OF WALL TO BE REMOVED FOR NEW DOOR OPENING EXIST. VIGA END TO BE REPAIRED OR REPLACED. 10'-4516" WOOD CANALE WITH METAL LINER NEW PORTAL W/ BRICK PARAPET, WOOD BEAMS POSTS AND CORBELS, STAINED NEW BAY WINDOW, WOOD TRIM, PAINTED. NEW METAL ROOF (COPPER) NEW WOOD DOOR W/ GLAZING IN PLACE OF EXISTING WINDOW OPENING 12'-3" TOP OF PARAPET 10'-5" TOP OF PARAPET 0'-0" FINISH FLOOR -0'-6 1/2" FINISH FLOOR REPLACE ROTTEN VIGAS , ADD NEW COPPER FLASHING @ EXPOSED VIGA ENDS. 5'-10" NEW WOOD WINDOW, PAINTED NEW STUCCO WALL RELOCATE EIXSTING DOWNSPOUT NEW WOOD GUARDRAIL, PAINTED 8'-1" PROPOSED ADDITION PROPOSED ADDITION OF BAY WINDOW 9'-4" 2'-6" 13'-10" TOP OF PARAPET 12'-8" TOP OF PARAPET 9'-2" BEAM BEARING 0'-0" FINISH FLOOR NEW STUCCO EXISTING GRADE 15'-1" MAX. BLDG. HEIGHT (EXISTING) INFILL EXISTING WINDOW OPENING. INSET TO SHOW OUTLINE/HISTORY OF OPENING; STUCCO FINISH A1 MAIN HOUSE - PROPOSED EXTERIOR ELEVATION - WEST 1/4" = 1'-0" 0' 2' 4' 8' All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Woven Architecture, LLC. MARK DATE DESCRIPTION I S S U E D PROJECT NO. FILE NAME DRAWN BY CHECKED BY S h e e t N a m e S h e e t N o . SHEET NO. OF SHEETS 7654321 A B C D E F JUSBASCHE RESIDENCE 616 ACEQUIA MADRE SANTA FE, NM 87501 HISTORIC DESIGN REVIEW BOARD NOT FOR CONSTRUCTION D1 MAIN HOUSE - PROPOSED EXTERIOR ELEVATION - SOUTH 1/4" = 1'-0" 0' 2' 4' 8' B1 MAIN HOUSE - EXISTING EXTERIOR ELEVATION - WEST 1/4" = 1'-0" 0' 2' 4' 8' E1 MAIN HOUSE - EXISTING EXTERIOR ELEVATION - SOUTH 1/4" = 1'-0" 0' 2' 4' 8' HMA-202 MAIN HOUSE EXISTING & PROPOSED EXTERIOR ELEVATIONS (SOUTH & WEST) 25010 HMA-202-ELEV (HDRB) BJF, AB BJF 06/15/26 HDRB 10/08/26 HDRB