DEVELOPMENT PLAN Paseo North 507 Paseo de Peralta Case #2023-6271 Jurisdiction: City of Santa Fe Section 24, Township: 17N, Range: 9E SITE JURISDICTION: CITY OF SANTA FE PROJECT NAME: PASEO NORTH DRAWING TYPE: COVER PAGE DRAWING DATE: 07/17/2024 BRADYN W. FURRY R.A. #6312 ARCHITECT'S SEAL SHEET 1 OF 3 VICINITY MAP NORTH 0 200 300 400100 GRAPHIC SCALE NOTES 1. Additional Development Plan drawings such as: Elevations, Lighting, Civil, Engineering Plan sheets, Roof Plans, are filed in the Map Room with the City of Santa Fe Case #2023-6271 2. CITY OF SANTA FE DRAINAGE: A. SUBJECT TO THE APPROVAL OF CITY OF SANTA FE PERMIT AND DEVELOPMENT REVIEW DIVISION STAFF, STORM DRAINAGE AND EROSION/SEDIMENT CONTROL IMPROVEMENTS SHALL BE EXECUTED IN CONJUNCTION WITH THE CONSTRUCITON OF EACH SEGMENT OF ROADS AND UTILITIES. THESE IMPROVEMENTS SHALL BE COMPLETED AND INSPECTED PRIOR TO THE ISSUANCE OF BUILDING PERMITS. B. MAINTENANCE OF PRIVATE DRAINAGE EASEMENTS AND DRAINAGE FACILITIES IS THE RESPONSIBILITY OF THE OWNER. THE CITY OF SANTA FE IS HEREBY GRANTED THE RIGHT TO ACCESS AND INSPECT THESE EASEMENTS AND DRAINAGE FACILITIES AT THE DISCRETION OF THE CITY. THE OWNER AGREES TO INDEMNIFY AND TO HOLD HARMLESS FROM ALL DAMAGE TO PERSONS OR PROPERTY RESULTING FROM THE CITY'S REASONABLE EXERCISE TO THEIR ACCESS AND INSPECTION RIGHT. CITY APPROVALS Approval by Santa Fe Planning Commission at their meeting on ____________________________________________, 20______ as Case No. 2023-6271 __________________________________________________________________ Planning Commission Chairperson Date __________________________________________________________________ Planning Commission Secretary Date Approved by the City of Santa Fe Land Use Department __________________________________________________________________ City Planner Date ___________________________________________________________________ City Engineer for Land Use Date KNOWN ALL MEN BY THESE PRESENTS THAT THE UNDERSIGNED OWNERS HAVE CAUSED THIS FINAL DEVELOPMENT PLAN TO BE PREPARED. ALL THAT APPEARS ON THIS PLAN IS MADE WITH THE FREE CONSENT AND IN ACCORDANCE WITH THE DESIRES OF THE OWNER. ____________________________________________________________ OWNER'S PRINTED NAME ____________________________________________________________ OWNER'S SIGNATURE THE FOREGOING WAS SWORN, ACKNOWLEDGED, AND SUBSCRIBED BEFORE ME BY: ____________________________________________________________ THIS _______ DAY OF _______________________ 20_______________ _________________________ _______________________ NOTARY PUBLIC MY COMMISSION EXPIRES AFFIDAVIT SHEET 2 OF 3 JURISDICTION: CITY OF SANTA FE PROJECT NAME: PASEO NORTH DRAWING TYPE: EXISTING CONDITIONS DRAWING DATE: 07/17/2024 EXISTING CONDITIONS Paseo North 507 Paseo de Peralta Case #2023-6271 Jurisdiction: City of Santa Fe Section 24, Township: 17N, Range: 9E PROPERTY INFORMATION ZONING: OVERLAYS: HISTORIC STATUS: LOT SIZE: EXISTING STRUCTURE SQ. FT.: EXISTING UTILITIES: FLOOD ZONE: BCDMAR (BUSINESS CAPITOL DISTRICT MARCY SUBDISTRICT) DOWNTOWN & EASTSIDE HISTORIC DISTRICT N/A .185 ACRES N/A ELECTRIC, SEWER, WATER N/A LEGAL LOT INFORMATION TRACT 1, RECORDED AS PLAT BOOK 895, PAGE 47 BRADYN W. FURRY R.A. #6312 ARCHITECT'S SEAL A-5 2 EXISTING RETAINING WALL STUCCO-CLAD ENCLOSURE FOR INDIVIDUAL 90 GALLON WASTE RECEPTACLES WITH STEEL GATES PASEO DE PERALTA UNIT 507-1 UNIT 507-2 UNIT 507-3 UNIT 507-4 COURTYARD PORTAL PORTAL PORTAL PORTAL PORTAL PORTAL EXISTING SIDEWALK MAGDALENA RD. EXISTING CURB 4 PARKING SPACES 2 PARKING SPACES (WITHIN CARPORT) 2 PARKING SPACES (WITHIN CARPORT) 8 PARKING SPACES TOTAL 507 PASEO DE PERALTA TRACT 1 .185 ACRES± LOT COVERAGE CALCULATIONS: BUILDING ROOF AREA = 4,235 S.F. PORTAL ROOF AREAS = 684 TOTAL ROOF AREA = 4,919 TOTAL LOT SIZE = 8,059 S.F. NO RESTRICTION COMMON OPEN SPACE = 614 OPEN SPACE = 887 S.F. PARKING SIGNAGE SIGN TYPE R7-8 (12"X18") -WHITE SIGN FIELD -GREEN BORDER AND LETTERING -WHITE ON BLUE BACKGROUND INTERNATIONAL SYMBOL OF ACCESSIBILITY OPTIONAL LANGUAGE REQUIRED LANGUAGE PER NMSA 197866-7-352.4C SIGN TYPE R7-8A (6"X12") -WHITE SIGN FIELD -GREEN BORDER AND LETTERING REQUIRED LANGUAGE (VAN ACCESSIBLE SPACE) ANSI 502.7 BOTTOM OF LOWEST SIGN 84" MIN. ABOVE THE GROUND IN PARKING LOT - ANSI 502.7 CITY OF SANTA FE CODES, TABLE 14-8.6, C.2 BCD 1 SPACE PER DWELLING UNIT TOTAL REQUIRED = 4 PARKING SPACES PROVIDED = 4 PARKING REQUIREMENTS 8' - 0"8' - 0"8' - 4"8' - 4"8' - 4" ADA PARALLEL CURB RAMP ZONING: BCD-MARCY 3' - 9 1/4" 19' - 2 25/32" ADA SIGNAGE (ON WALL OF CARPORT) NO PARKING 1' HIGH X 2" WIDE LETTERING 2" WIDE BLUE STRIPING ON CONCRETE AT PARKING SPACES, ACCESSIBLE AISLE AND ACCESSIBLE PATH DIAGONAL STRIPING PARKING STRIPE DETAIL ACCESSIBLE ROUTE SIGNAGE - ON SIDE OF WALL SIDEWALK ACCESS / ACCESSIBLE ROUTE ENDS AHEAD ACCESSIBLE ROUTE SIGNAGE SLOPE = 3.06% MAX. ACCESSIBLE ROUTE NEW BLUE WHEELCHAIR SYMBOL -CENTER ON PARKING SPOT ADA SIGNAGE 4' - 11 7/8"7' - 1 3/4" SLOPE = .13% MAX. SLOPE = 1.24% MAX. CONCRETE DRIVE UP SLOPE = 7% CONCRETE CONCRETE SIDEWALK CONCRETE SIDEWALK OPEN SIDE BELOW SOFTSCAPE ACCESSIBLE ROUTE TO 511 2% SLOPE MAX. SITE DEVELOPMENT PLAN Paseo North 507 Paseo de Peralta Case #2023-6271 Jurisdiction: City of Santa Fe Section 24, Township: 17N, Range: 9E JURISDICTION: CITY OF SANTA FE PROJECT NAME: PASEO NORTH DRAWING TYPE: SITE DEVELOPMENT PLAN DRAWING DATE: 07/17/2024 SHEET 3 OF 3 PROJECT DATA BRADYN W. FURRY R.A. #6312 ARCHITECT'S SEAL OPEN SPACE: 10 percent of the lot area LANDSCAPE: Landscape treatment required in yards and open space. Street trees and landscape treatment required if planting strip exists. Asphalt or concrete pavement prohibited in planting strip. HEIGHT OF WALLS AND FENCES: Maximum 4' PLACEMENT OF OFF-STREET PARKING Parking prohibited in front yard. PORTALS IN THE ROW: None NORTH 0 16 24 328 GRAPHIC SCALE PROJECT SITE: Acreage: .185 acres Flood Plain: N/A Flood Way Square feet: N/A Net Acreage: .185 acres Zoning: BCDMAR (Business Capitol District Marcy Subdistrict) OVERLAY ZONING: Downtown and Eastside Historic District Historic Downtown Archaeological Review District BUILDINGS: 4,235 Sq. Ft. HEIGHT: Marcy Subdistrict Maximum Height: 42' Downtown and Eastside Historic District: 24' Building: 23'- 0 1/2" LOT COVERAGE: Marcy Subdistrict: No Restriction BUILDING PLACEMENT: No yard requirements: Front required yard equal to the average depth of existing front yards on the block shall be required for (a) the east side of Washington Avenue between Place Avenue and Paseo de Peralta (Hillside); and the west side of Grant Avenue between Place Avenue and Paseo de Peralta. Elsewhere in the subdistrict there are no required yards. DEVELOPMENT PLAN Paseo North 511 Paseo de Peralta Case #2023-6271 Jurisdiction: City of Santa Fe Section 24, Township: 17N, Range: 9E JURISDICTION: CITY OF SANTA FE PROJECT NAME: PASEO NORTH DRAWING TYPE: COVER PAGE DRAWING DATE: 06/01/2024 BRADYN W. FURRY R.A. #6312 ARCHITECT'S SEAL SHEET 1 OF 4 NOTES 1. Additional Development Plan drawings such as: Elevations, Lighting, Civil, Engineering Plan sheets, Roof Plans, are filed in the Map Room with the City of Santa Fe Case #2023-6271 2. CITY OF SANTA FE DRAINAGE: A. SUBJECT TO THE APPROVAL OF CITY OF SANTA FE PERMIT AND DEVELOPMENT REVIEW DIVISION STAFF, STORM DRAINAGE AND EROSION/SEDIMENT CONTROL IMPROVEMENTS SHALL BE EXECUTED IN CONJUNCTION WITH THE CONSTRUCITON OF EACH SEGMENT OF ROADS AND UTILITIES. THESE IMPROVEMENTS SHALL BE COMPLETED AND INSPECTED PRIOR TO THE ISSUANCE OF BUILDING PERMITS. B. MAINTENANCE OF PRIVATE DRAINAGE EASEMENTS AND DRAINAGE FACILITIES IS THE RESPONSIBILITY OF THE OWNER. THE CITY OF SANTA FE IS HEREBY GRANTED THE RIGHT TO ACCESS AND INSPECT THESE EASEMENTS AND DRAINAGE FACILITIES AT THE DISCRETION OF THE CITY. THE OWNER AGREES TO INDEMNIFY AND TO HOLD HARMLESS FROM ALL DAMAGE TO PERSONS OR PROPERTY RESULTING FROM THE CITY'S REASONABLE EXERCISE TO THEIR ACCESS AND INSPECTION RIGHT. VICINITY MAP NORTH SITE 0 200 300 400100 GRAPHIC SCALE CITY APPROVALS Approval by Santa Fe Planning Commission at their meeting on ____________________________________________, 20______ as Case No. 2023-6271 __________________________________________________________________ Planning Commission Chairperson Date __________________________________________________________________ Planning Commission Secretary Date Approved by the City of Santa Fe Land Use Department __________________________________________________________________ City Planner Date ___________________________________________________________________ City Engineer for Land Use Date KNOWN ALL MEN BY THESE PRESENTS THAT THE UNDERSIGNED OWNERS HAVE CAUSED THIS FINAL DEVELOPMENT PLAN TO BE PREPARED. ALL THAT APPEARS ON THIS PLAN IS MADE WITH THE FREE CONSENT AND IN ACCORDANCE WITH THE DESIRES OF THE OWNER. ____________________________________________________________ OWNER'S PRINTED NAME ____________________________________________________________ OWNER'S SIGNATURE THE FOREGOING WAS SWORN, ACKNOWLEDGED, AND SUBSCRIBED BEFORE ME BY: ____________________________________________________________ THIS _______ DAY OF _______________________ 20_______________ _________________________ _______________________ NOTARY PUBLIC MY COMMISSION EXPIRES AFFIDAVIT DEVELOPMENT PLAN Paseo North 511 Paseo de Peralta Case #2023-6271 Jurisdiction: City of Santa Fe Section 24, Township: 17N, Range: 9E JURISDICTION: CITY OF SANTA FE PROJECT NAME: PASEO NORTH DRAWING TYPE: CONDITIONS OF APPROVAL DRAWING DATE: 06/01/2024 BRADYN W. FURRY R.A. #6312 ARCHITECT'S SEAL SHEET 2 OF 4 SHEET 3 OF 4 JURISDICTION: CITY OF SANTA FE PROJECT NAME: PASEO NORTH DRAWING TYPE: EXISTING CONDITIONS DRAWING DATE: 06/01/2024 EXISTING CONDITIONS Paseo North 511 Paseo de Peralta Case #2023-6271 Jurisdiction: City of Santa Fe Section 24, Township: 17N, Range: 9E PROPERTY INFORMATION ZONING: OVERLAYS: HISTORIC STATUS: LOT SIZE: EXISTING STRUCTURE SQ. FT.: EXISTING UTILITIES: FLOOD ZONE: R21 DOWNTOWN & EASTSIDE HISTORIC DISTRICT N/A .378 ACRES N/A ELECTRIC, SEWER, WATER N/A LEGAL LOT INFORMATION TRACT 1-A, RECORDED AS PLAT BOOK 895, PAGE 47 BRADYN W. FURRY R.A. #6312 ARCHITECT'S SEAL UNIT 511-1 UNIT 511-2 UNIT 511-3 UNIT 511-4 UNIT 511-5 COURTYARD PORTAL PORTAL PORTAL PORTAL PORTAL 4 PARKING SPACES 6 TOTAL PARKING SPACES 1 PARKING SPACE (IN GARAGE) PORTAL PASEO DE PERALTA 511 PASEO DE PERALTA TRACT I-A .378 ACRES± REAR SETBACK 5' - 0" SIDE SETBACK 5' - 0" SIDE SETBACK 5' - 0" SIDE SETBACK 5' - 0" SIDE SETBACK 5' - 0" FRONT SETBACK 7' - 0" SIDE SETBACK 5' - 0" BUILDING 2 ROOF = 3,014.21 S.F. BUILDING 1 ROOF = 3,386.62 S.F. UNIT 1 PRIVATE OPEN SPACE = 321 UNIT 2 PRIVATE OPEN SPACE = 345 UNIT 3 PRIVATE OPEN SPACE = 284 UNIT 4 PRIVATE OPEN SPACE = 776 UNIT 5 PRIVATE OPEN SPACE = 351 EXISTING HISTORIC STONE RETAINING WALL STUCCO-CLAD YARDWALL, TYP. STUCCO-CLAD ENCLOSURE FOR INDIVIDUAL 90 GALLON WASTE RECEPTACLES WITH STEEL GATES EXISTING CURB AND GUTTER LOT COVERAGE CALCULATIONS: BUILDING ROOF AREAS = 6,212 S.F. PORTAL ROOF AREAS = 1,562 S.F. TOTAL LOT COVERAGE = 7,774 S.F. TOTAL LOT SIZE = 16,466 S.F. 7,519/16,466 = 47% ALLOWED = 55% EXISTING STONE RETAINING WALL ABOVE EXISTING STONE RETAINING WALL ABOVE NEW 20' WIDE CURB CUT COMMON OPEN SPACE = 908 PARKING SIGNAGE SIGN TYPE R7-8 (12"X18") -WHITE SIGN FIELD -GREEN BORDER AND LETTERING -WHITE ON BLUE BACKGROUND INTERNATIONAL SYMBOL OF ACCESSIBILITY OPTIONAL LANGUAGE REQUIRED LANGUAGE PER NMSA 197866-7-352.4C SIGN TYPE R7-8A (6"X12") -WHITE SIGN FIELD -GREEN BORDER AND LETTERING REQUIRED LANGUAGE (VAN ACCESSIBLE SPACE) ANSI 502.7 BOTTOM OF LOWEST SIGN 84" MIN. ABOVE THE GROUND IN PARKING LOT - ANSI 502.7 8' - 0" 8' - 0" 8' - 1 1/4" 8' - 1 1/2" 8' - 1" 19' - 0" ADA SIGNAGE ZONING: R-21 S44°10'59"W 77.41' 39.49' S67°11'55"W N44°52'22"W 31.53' S19°25'09"W 39.25' 78.11' S71°13'23"E S65°32'02"E 56.58' 43.51' S56°59'19"E S40°13'21"W 92.80' N51°01'56"W 127.99' PARKING STRIPE, TYP. BIKE 2 SPOTS BIKE 1 SPOT BIKE 1 SPOT BIKE 1 SPOT BIKE 1 SPOT CITY OF SANTA FE, TABLE 14-8.6-1 ATTACHED DWELLING UNIT (2-5 UNITS): 2 SPACES PER DWELLING UNIT PARKING REQUIREMENTS 1' HIGH X 2" WIDE LETTERING 2" WIDE BLUE STRIPING ON CONCRETE AT PARKING SPACES, ACCESSIBLE AISLE AND ACCESSIBLE PATH DIAGONAL STRIPING PARKING STRIPE DETAIL CONCRETE DRIVE 1 PARKING SPACE (IN GARAGE) ACCESSIBLE ROUTE ADA PARALLEL CURB RAMP NEW BLUE WHEELCHAIR SYMBOL -CENTER ON PARKING SPOT 5' - 0" 5' - 0" 7' - 1 3/4" UP SLOPE = 7% SLOPE = 3.06% MAX. SLOPE = 0.95% MAX. SLOPE = 2.00% MAX. CONCRETE SIDEWALK PORTAL CONCRETE SIDEWALK PORTAL CONCRETE SIDEWALK RAMP UP RAMP UP RAMP UP RAMP UP SLOPE = 1:12 MAX. SLOPE = 1:12 MAX. SLOPE - 1:12 SLOPE - 1:12 CONCRETE SIDEWALK CONCRETE SOFTSCAPE ACCESSIBLE ROUTE TO 507 2% SLOPE MAX. EXISTING STUCCO-CLAD YARDWALL ABOVE SITE DEVELOPMENT PLAN Paseo North 507 Paseo de Peralta Case #2023-6271 Jurisdiction: City of Santa Fe Section 24, Township: 17N, Range: 9E JURISDICTION: CITY OF SANTA FE PROJECT NAME: PASEO NORTH DRAWING TYPE: SITE DEVELOPMENT PLAN DRAWING DATE: 06/01/2024 SHEET 4 OF 4 PROJECT DATA BRADYN W. FURRY R.A. #6312 ARCHITECT'S SEAL LOT COVERAGE: R21: Single-family or multiple-family of fewer than 6 units: 40%; 55% if private open space is provided. BUILDING PLACEMENT: Generally, setbacks are established by a development plan approved by the Planning Commission. OPEN SPACE: Single-family dwellings or multiple- family dwellings : 250 square feet of common and/ or private open space for each unit LANDSCAPE: Landscape treatment required in yards and open space. Street trees and landscape treatment required if planting strip exists. Asphalt or concrete pavement prohibited in planting strip. PLACEMENT OF OFF-STREET PARKING Attached dwelling unit (2-5 units): 2 spaces per dwelling unit NORTH 0 16 24 328 GRAPHIC SCALE PROJECT SITE: Acreage: .378 acres Flood Plain: N/A Flood Way Square feet: N/A Net Acreage: .378 acres Zoning: R21 OVERLAY ZONING: Downtown and Eastside Historic District Historic Downtown Archaeological Review District BUILDINGS: 6,212 Sq. Ft. HEIGHT: Marcy Subdistrict Maximum Height: 24' Downtown and Eastside Historic District: 24' Building: 24' A5 2 EXISTING RETAINING WALL STUCCO-CLAD ENCLOSURE FOR INDIVIDUAL 90 GALLON WASTE RECEPTACLES WITH STEEL GATES PASEO DE PERALTA UNIT 507-1 UNIT 507-2 UNIT 507-3 UNIT 507-4 COURTYARD PORTAL PORTAL PORTAL PORTAL PORTAL PORTAL EXISTING SIDEWALK MAGDALENA RD. EXISTING CURB 4 PARKING SPACES 2 PARKING SPACES (WITHIN CARPORT) 2 PARKING SPACES (WITHIN CARPORT) 8 PARKING SPACES TOTAL 507 PASEO DE PERALTA TRACT 1 .185 ACRES± LOT COVERAGE CALCULATIONS: BUILDING ROOF AREA = 4,235 S.F. PORTAL ROOF AREAS = 684 TOTAL ROOF AREA = 4,919 TOTAL LOT SIZE = 8,059 S.F. NO RESTRICTION COMMON OPEN SPACE = 614 OPEN SPACE = 887 S.F. PARKING SIGNAGE SIGN TYPE R7-8 (12"X18") -WHITE SIGN FIELD -GREEN BORDER AND LETTERING -WHITE ON BLUE BACKGROUND INTERNATIONAL SYMBOL OF ACCESSIBILITY OPTIONAL LANGUAGE REQUIRED LANGUAGE PER NMSA 197866-7-352.4C SIGN TYPE R7-8A (6"X12") -WHITE SIGN FIELD -GREEN BORDER AND LETTERING REQUIRED LANGUAGE (VAN ACCESSIBLE SPACE) ANSI 502.7 BOTTOM OF LOWEST SIGN 84" MIN. ABOVE THE GROUND IN PARKING LOT - ANSI 502.7 CITY OF SANTA FE CODES, TABLE 14-8.6, C.2 BCD 1 SPACE PER DWELLING UNIT TOTAL REQUIRED = 4 PARKING SPACES PROVIDED = 4 PARKING REQUIREMENTS 8' - 0"8' - 0"8' - 4"8' - 4"8' - 4" ADA PARALLEL CURB RAMP ZONING: BCD-MARCY 3' - 9 1/4" 19' - 2 25/32" ADA SIGNAGE (ON WALL OF CARPORT) NO PARKING 1' HIGH X 2" WIDE LETTERING 2" WIDE BLUE STRIPING ON CONCRETE AT PARKING SPACES, ACCESSIBLE AISLE AND ACCESSIBLE PATH DIAGONAL STRIPING PARKING STRIPE DETAIL ACCESSIBLE ROUTE SIGNAGE - ON SIDE OF WALL SIDEWALK ACCESS / ACCESSIBLE ROUTE ENDS AHEAD ACCESSIBLE ROUTE SIGNAGE SLOPE = 3.06% MAX. ACCESSIBLE ROUTE NEW BLUE WHEELCHAIR SYMBOL -CENTER ON PARKING SPOT ADA SIGNAGE 4' - 11 7/8"7' - 1 3/4" SLOPE = .13% MAX. SLOPE = 1.24% MAX. CONCRETE DRIVE UP SLOPE = 7% CONCRETE CONCRETE SIDEWALK CONCRETE SIDEWALK OPEN SIDE BELOW SOFTSCAPE ACCESSIBLE ROUTE TO 511 2% SLOPE MAX. drawing scale: 1/8" = 1'-0" 9/11/2024 10:21:57 AM A1 SITE PLAN 507 Paseo de Peralta Santa Fe, NM PERALTA'S WALK, LLC. PASEO NORTH N 09/11/2024 36SL 37SL 38SL 39SL 40SL 41SL 42SL 35SL 34SL SLOPE - 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE - 1/4" / FT. SLOPE : 1/4" / FT. #KEYNOTES: 1. 60 MIL, LOW-SLOPE, TPO ROOFING OVER 80 PSI RECOVERY BOARD 2. ROOF DRAIN WITH OVERFLOW 3. METAL DRIP EDGE 4. STONE CHIMNEY CAP 5. STEEL FIREPLACE EXHAUST PIPE 6. DECK BELOW 7. YARDWALL BELOW 8. SOFTSCAPE BELOW 9. CONCRETE PAD BELOW 10. STONE COLUMN CAP BELOW 11. PARAPET 12. METAL ROOFING 13. EDGE OF WALL BELOW 1 1 1 1 1 1 1 12 12 12 1 1 1 1 1 6 6 6 2 2 2 2 2 3 3 9 9 10 10 9 12 9 3 3 9 9 10 8 8 8 8 7 7 7 5 5 5 4 4 4 3 3 3 3 3 3 3 3 3 3 8 10 10 TYP. TYP. 3 2 3 3 11 11 11 11 11 11 11 11 11 11 11 11 11 9 SLOPE : 1/4" / FT. 12 12 12 12 13 13 13 13 13 2' - 0" 3' - 4 1/4"3' - 4 1/4" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" SLOPE : 1/4" / FT. 2 drawing scale: 1/4" = 1'-0" 9/11/2024 10:21:59 AM A3 ROOF PLAN 507 Paseo de Peralta Santa Fe, NM PERALTA'S WALK, LLC. PASEO NORTH N 09/11/2024 FIRST FLOOR 0' - 0" SECOND FLOOR 10' - 6" 24' HEIGHT MAXIMUM EXISTING TOPOGRAPHY 3-209 3-109 25 23' - 0 1/2" 22' - 0 1/2" 6' - 9 1/2" EXISTING RETAINING WALL STEEL FASCIA, TYP. STEEL BEAM, TYP. STEEL FASCIA, TYP. STEEL BEAM, TYP. STUCCO, TYP. 3' - 0" 1 A-6 FIRST FLOOR 0' - 0" SECOND FLOOR 10' - 6" 24' HEIGHT MAXIMUM EXISTING TOPOGRAPHY 17 26 101 31 30 STEEL BEAM, TYP. STEEL FASCIA, TYP. 7' - 1" 6' - 9 1/2" 6' - 9 1/2" 7' - 1" 7' - 9" 7' - 9" STUCCO,TYP. STUCCO, TYP. STONE CAP, TYP. SCONCE, TYP. STEEL BEAMSTEEL GATESTEEL RAILING STEEL RAILING STUCCO COLUMN, TYP. 20' - 9 1/4" 22' - 0 1/2" 20' - 9 1/4" 11' - 6" 11' - 6" 8' - 0" 7' - 0" 8' - 8" 9' - 0" 2 A-6 3 A-6 A-9 5 OPEN OPEN drawing scale: 1/4" = 1'-0" 9/11/2024 10:22:00 AM A5 EXTERIOR ELEVATIONS 507 Paseo de Peralta Santa Fe, NM PERALTA'S WALK, LLC. PASEO NORTH 1/4" = 1'-0" 1 NORTH 1/4" = 1'-0" 2 EAST 09/11/2024 PASEO DE PERALTA EXISTING SIDEWALK MAGDALENA RD. PROPERTY LINE PROPERTY LINE Luminaire Schedule Symbol Qty Label Arrangement Description LLF Luminaire Lumens Luminaire Watts Total Watts 18 OLCS 8 WH Single OLCS 8 WH 1.000 522 8.93 160.74 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min Max/Avg CalcPts_1 Illuminance Fc 0.49 1.1 0.1 4.90 11.00 2.24 CalcPts_2 Illuminance Fc 0.21 0.4 0.0 N.A. N.A. 1.90 CalcPts_3 Illuminance Fc 0.49 0.7 0.1 4.90 7.00 1.43 CalcPts_4 Illuminance Fc 0.07 0.3 0.0 N.A. N.A. 4.29 CalcPts_5 Illuminance Fc 0.21 0.3 0.1 2.10 3.00 1.43 0.1 0.2 0.3 0.3 0.3 0.1 0.2 0.3 0.4 0.4 0.1 0.2 0.3 0.4 0.4 0.1 0.2 0.3 0.4 0.4 0.2 0.3 0.4 0.4 0.4 0.2 0.3 0.4 0.4 0.4 0.2 0.3 0.4 0.4 0.4 0.2 0.3 0.4 0.4 0.4 0.2 0.3 0.4 0.4 0.4 0.2 0.3 0.4 0.4 0.4 0.2 0.3 0.4 0.5 0.5 0.2 0.3 0.4 0.5 0.5 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.5 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.5 0.5 0.4 0.4 0.4 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.5 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.6 0.7 0.7 0.7 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.4 0.4 0.3 0.6 0.6 0.7 0.7 0.8 0.8 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.7 0.8 0.8 0.8 0.8 0.8 0.8 0.7 0.7 0.6 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.7 0.8 0.9 0.9 0.9 0.9 0.8 0.8 0.7 0.6 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.7 0.8 0.9 1.0 1.0 0.9 0.9 0.8 0.7 0.6 0.6 0.5 0.4 0.4 0.4 0.3 0.3 0.7 0.8 1.0 1.0 1.0 1.0 0.9 0.8 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.7 0.9 1.0 1.1 1.1 1.0 0.9 0.8 0.8 0.7 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.7 0.9 1.0 1.1 1.1 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.5 0.4 0.4 0.4 0.3 0.7 0.9 1.0 1.1 1.1 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.5 0.4 0.4 0.4 0.3 0.7 0.8 1.0 1.1 1.1 1.0 1.0 0.9 0.8 0.7 0.6 0.5 0.5 0.4 0.4 0.4 0.4 0.7 0.8 0.9 1.0 1.0 1.0 1.0 0.9 0.8 0.7 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.7 0.8 0.9 0.9 0.9 0.9 0.9 0.8 0.7 0.7 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.6 0.7 0.8 0.8 0.8 0.8 0.8 0.7 0.7 0.6 0.5 0.5 0.4 0.5 0.5 0.5 0.4 0.5 0.5 0.6 0.7 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.4 0.4 0.5 0.5 0.5 0.4 0.4 0.5 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.4 0.5 0.5 0.5 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.5 0.5 0.5 0.2 0.3 0.4 0.5 0.5 0.3 0.3 0.4 0.5 0.5 0.3 0.3 0.4 0.4 0.5 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.4 0.4 0.4 0.2 0.3 0.4 0.4 0.4 0.2 0.3 0.4 0.4 0.4 0.2 0.3 0.4 0.4 0.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.3 0.3 0.1 0.2 0.4 0.4 0.4 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.4 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.2 0.3 0.3 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.4 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.4 0.4 0.4 0.5 0.5 0.5 0.2 0.3 0.4 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.2 0.3 0.4 0.5 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.7 0.7 0.1 0.2 0.4 0.5 0.6 0.5 0.5 0.5 0.4 0.4 0.5 0.5 0.6 0.6 0.6 0.7 0.7 0.2 0.3 0.4 0.6 0.7 0.7 0.2 0.3 0.4 0.6 0.7 0.7 0.2 0.3 0.4 0.6 0.7 0.7 0.2 0.3 0.4 0.6 0.6 0.7 0.2 0.3 0.4 0.6 0.7 0.7 0.1 0.3 0.4 0.6 0.7 0.7 0.1 0.3 0.4 0.5 0.6 0.6 0.5 0.5 0.4 0.4 0.5 0.5 0.5 0.6 0.6 0.6 0.7 0.2 0.3 0.4 0.5 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.5 0.5 0.4 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.2 0.2 0.3 0.3 0.3 0.2 0.2 0.2 24064 N E W M E X I C O C H R I S T O P H E R J. W I L L I A M S P R O F E S S I O NAL E N G I N E E R 09.10.2024 drawing scale: 1/4" = 1'-0" 9/10/2024 1:54:23 PM E200 ELECTRICAL PHOTOMETRIC PLAN 507 Paseo de Peralta Santa Fe, NM PERALTA'S WALK, LLC. PASEO NORTH SCALE: 1/4" = 1'-0" ELECTRICAL PHOTOMETRIC PLAN 1 UNIT 511-1 UNIT 511-2 UNIT 511-3 UNIT 511-4 UNIT 511-5 COURTYARD PORTAL PORTAL PORTAL PORTAL PORTAL 4 PARKING SPACES 6 TOTAL PARKING SPACES 1 PARKING SPACE (IN GARAGE) PORTAL PASEO DE PERALTA 511 PASEO DE PERALTA TRACT I-A .378 ACRES± REAR SETBACK 5' - 0" SIDE SETBACK 5' - 0" SIDE SETBACK 5' - 0" SIDE SETBACK 5' - 0" SIDE SETBACK 5' - 0" FRONT SETBACK 7' - 0" SIDE SETBACK 5' - 0" BUILDING 2 ROOF = 3,014.21 S.F. BUILDING 1 ROOF = 3,386.62 S.F. UNIT 1 PRIVATE OPEN SPACE = 321 UNIT 2 PRIVATE OPEN SPACE = 345 UNIT 3 PRIVATE OPEN SPACE = 284 UNIT 4 PRIVATE OPEN SPACE = 776 UNIT 5 PRIVATE OPEN SPACE = 351 EXISTING HISTORIC STONE RETAINING WALL STUCCO-CLAD YARDWALL, TYP. EXISTING STUCCO-CLAD YARDWALL ABOVE STUCCO-CLAD ENCLOSURE FOR INDIVIDUAL 90 GALLON WASTE RECEPTACLES WITH STEEL GATES EXISTING CURB AND GUTTER LOT COVERAGE CALCULATIONS: BUILDING ROOF AREAS = 6,212 S.F. PORTAL ROOF AREAS = 1,562 S.F. TOTAL LOT COVERAGE = 7,774 S.F. TOTAL LOT SIZE = 16,466 S.F. 7,519/16,466 = 47% ALLOWED = 55% EXISTING STONE RETAINING WALL ABOVE EXISTING STONE RETAINING WALL ABOVE NEW 20' WIDE CURB CUT COMMON OPEN SPACE = 908 PARKING SIGNAGE SIGN TYPE R7-8 (12"X18") -WHITE SIGN FIELD -GREEN BORDER AND LETTERING -WHITE ON BLUE BACKGROUND INTERNATIONAL SYMBOL OF ACCESSIBILITY OPTIONAL LANGUAGE REQUIRED LANGUAGE PER NMSA 197866-7-352.4C SIGN TYPE R7-8A (6"X12") -WHITE SIGN FIELD -GREEN BORDER AND LETTERING REQUIRED LANGUAGE (VAN ACCESSIBLE SPACE) ANSI 502.7 BOTTOM OF LOWEST SIGN 84" MIN. ABOVE THE GROUND IN PARKING LOT - ANSI 502.7 8' - 0" 8' - 0" 8' - 1 1/4" 8' - 1 1/2" 8' - 1" 19' - 0" ADA SIGNAGE ZONING: R-21 S44°10'59"W 77.41' 39.49' S67°11'55"W N44°52'22"W 31.53' S19°25'09"W 39.25' 78.11' S71°13'23"E S65°32'02"E 56.58' 43.51' S56°59'19"E S40°13'21"W 92.80' N51°01'56"W 127.99' PARKING STRIPE, TYP. BIKE 2 SPOTS BIKE 1 SPOT BIKE 1 SPOT BIKE 1 SPOT BIKE 1 SPOT CITY OF SANTA FE, TABLE 14-8.6-1 ATTACHED DWELLING UNIT (2-5 UNITS): 2 SPACES PER DWELLING UNIT PARKING REQUIREMENTS 1' HIGH X 2" WIDE LETTERING 2" WIDE BLUE STRIPING ON CONCRETE AT PARKING SPACES, ACCESSIBLE AISLE AND ACCESSIBLE PATH DIAGONAL STRIPING PARKING STRIPE DETAIL CONCRETE DRIVE 1 PARKING SPACE (IN GARAGE) ACCESSIBLE ROUTE ADA PARALLEL CURB RAMP NEW BLUE WHEELCHAIR SYMBOL -CENTER ON PARKING SPOT 5' - 0" 5' - 0" 7' - 1 3/4" UP SLOPE = 7% SLOPE = 3.06% MAX. SLOPE = 0.95% MAX. SLOPE = 2.00% MAX. CONCRETE SIDEWALK PORTAL CONCRETE SIDEWALK PORTAL CONCRETE SIDEWALK RAMP UP RAMP UP RAMP UP RAMP UP SLOPE = 1:12 MAX. SLOPE = 1:12 MAX. SLOPE - 1:12 SLOPE - 1:12 CONCRETE SIDEWALK CONCRETE SOFTSCAPE ACCESSIBLE ROUTE TO 507 2% SLOPE MAX. drawing scale: 1/8" = 1'-0" 9/11/2024 10:25:29 AM A1 SITE PLAN 511 Paseo de Peralta Santa Fe, NM PERALTA'S WALK, LLC. PASEO NORTH N 09/11/2024 #KEYNOTES: 1. 60 MIL, LOW-SLOPE, TPO ROOFING OVER 80 PSI RECOVERY BOARD 2. ROOF DRAIN WITH OVERFLOW 3. METAL DRIP EDGE 4. STONE CHIMNEY CAP 5. STEEL FIREPLACE EXHAUST PIPE 6. DECK BELOW 7. METAL ROOFING 8. SOFTSCAPE BELOW 9. CONCRETE PAD BELOW 10. STONE COLUMN CAP BELOW 11. PARAPET 12. EDGE OF ROOF BELOW 13. ROOF DRAIN WITH OVERFLOW BELOW DECKING ON PEDESTALS 14. OPENING IN PARAPET FOR ROOF DRAINAGE SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. 1 1 1 1 1 SLOPE : 1/4" / FT. 1 7 1 1 1 1 1 7 1 1 7 7 7 7 7 7 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 33 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 5 5 5 5 5 5 5 6 6 6 9 10 10 10 10 10 TYP. 10 TYP. 9 11 11 11 11 11 11 11 11 11 11 11 88 8 8 6 6 8 8 12 12 84SL 85SL 82SL 81SL 80SL 78SL 79SL 77SL 76SL 83SL 7 7 9 1 7 SLOPE : 1/4" / FT. 1 9 SLOPE : 1/4" / FT. 7 SLOPE : 1/4" / FT. 3 3 12 12 13 13 SLOPE : 1/4" / FT. 13 6 BELOW 12 13 13 SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. SLOPE : 1/4" / FT.13 3" SLOPE : 1/4" / FT. 14 14 SLOPE : 1/4" / FT. SLOPE : 1/4" / FT. 14 14 1414 2 SLOPE : 1/4" / FT. 3 drawing scale: 1/4" = 1'-0" 9/11/2024 10:25:30 AM A3 ROOF PLAN 511 Paseo de Peralta Santa Fe, NM PERALTA'S WALK, LLC. PASEO NORTH N 09/11/2024 FIRST FLOOR 0' - 0" SECOND FLOOR 10' - 6" 24' HEIGHT MAXIMUM EXISTING TOPOGRAPHY STEEL FASCIA STEEL BEAM, TYP. STEEL CHIMNEY EXHAUST PIPE EXISTING YARDWALL, TYP. EXISTING YARDWALL, TYP. 27' - 6" 20' - 8 3/4" STUCCO, TYP. 2' - 0" 2' - 0" FIRST FLOOR 0' - 0" SECOND FLOOR 10' - 6" 24' HEIGHT MAXIMUM EXISTING TOPOGRAPHY 6' - 0" MAX. 50 2-202 3-200 49 48 75 74 4-200 3-100B 72 73 10' - 9 1/2" 10' - 9 1/2" 10' - 9 1/2" STEEL FASCIA, TYP. STEEL BEAM, TYP. STEEL FASCIA, TYP. STEEL BEAM, TYP. STEEL CHIMNEY EXHAUST PIPE STEEL CHIMNEY EXHAUST PIPE STEEL CHIMNEY EXHAUST PIPE 26' - 0" 15' - 6" 24' - 0" 22' - 8 3/4" 12' - 3 1/4" 7' - 0" 26' - 2 3/4" 27' - 6" 12' - 3 1/2" 12' - 3 1/2" 15' - 8 3/4" 17' - 0" 12' - 3 1/2" 24' - 8 3/4" STUCCO, TYP. STUCCO, TYP. STEEL BEAM, TYP. STEEL BEAM, TYP. STUCCO, TYP. STEEL BEAM, TYP. STEEL FASCIA, TYP. STONE CAP. TYP. STONE CAP. TYP.STONE CAP, TYP. EXISTING RETAINING WALL, TYP. EXISTING YARDWALL, TYP. STUCCO, TYP. 1' - 9 1/4" FIRST FLOOR 0' - 0" SECOND FLOOR 10' - 6" 24' HEIGHT MAXIMUM STEEL FASCIA STEEL BEAM, TYP. STEEL BEAM, ETC. STEEL FASCIA STUCCO, TYP. STEEL FIREPLACE EXHAUST PIPE STEEL BEAM, TYP. STEEL BEAM, ETC. STONE CAP STEEL FIREPLACE EXHAUST PIPE STEEL FIREPLACE EXHAUST PIPE STUCCO, TYP. STONE CAP STONE CAP 3 1 32 36 35 34 33 2 1-207B 2-206B STUCCO, TYP. STEEL FASCIA METAL ROOFING STEEL BEAM, TYP. STEEL BEAM STONE CAP, TYP. EXISTING TOPOGRAPHY STEEL BEAM, TYP. STEEL BEAM STEEL COLUMN, TYP. METAL ROOFING STUCCO-CLAD YARDWALL STONE CAP, TYP. STEEL COLUMN, TYP. 10' - 0" 20' - 8 3/4" 22' - 0" 24' - 0" 12' - 3 1/4" 15' - 6" 7' - 0" 9' - 0" 10' - 0" 7' - 11 1/2" 7' - 11 1/2" 9' - 11 1/2" 8' - 9 1/2" 8' - 9 1/2" 6' - 9 1/2" 6' - 9 1/2" 6' - 9 1/2" 2' - 0" 2' - 0" 2' - 0" 1-100B 1-100C 8' - 0" 1 A-6 FIRST FLOOR 0' - 0" SECOND FLOOR 10' - 6" 24' HEIGHT MAXIMUM EXISTING TOPOGRAPHY 47 46 45 3760 68 5-112 1-114 3-100A STEEL BEAM, TYP. STEEL CHIMNEY EXHAUST PIPE, TYP. STEEL FASCIA STUCCO STEEL FASCIA STEEL BEAM, TYP. STEEL CHIMNEY EXHAUST PIPE, TYP. STEEL CHIMNEY EXHAUST PIPE, TYP. STONE CAP STONE CAP STUCCO STUCCO STEEL BEAM, TYP.STEEL BEAM, TYP. 11' - 0" 8' - 1" 12' - 3 1/2" 10' - 9 1/2" 10' - 9 1/2" 10' - 9 1/2" 8' - 1"10' - 0" 20' - 8 3/4" 20' - 8 3/4" A-9 2 8' - 6" drawing scale: 1/8" = 1'-0" 9/11/2024 10:25:32 AM A5 EXTERIOR ELEVATIONS 511 Paseo de Peralta Santa Fe, NM PERALTA'S WALK, LLC. PASEO NORTH 1/8" = 1'-0" 1 NORTH 1/8" = 1'-0" 2 EAST 1/8" = 1'-0" 3 SOUTH 1/8" = 1'-0" 4 WEST 09/11/2024 DW DW DW REF REF REF REF S19°25'09"W 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.5 0.5 0.5 0.6 0.6 0.6 0.6 0.5 0.4 0.4 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.2 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.5 0.5 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.7 0.6 0.5 0.4 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.4 0.5 0.6 0.7 0.7 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.7 0.7 0.6 0.5 0.4 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.5 0.6 0.7 0.8 0.8 0.7 0.6 0.5 0.7 0.8 0.7 0.7 0.5 0.4 0.3 0.4 0.4 0.4 0.4 0.4 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.5 0.6 0.8 0.9 0.8 0.8 0.6 0.5 0.7 0.7 0.7 0.6 0.5 0.3 0.2 0.4 0.5 0.5 0.5 0.4 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.5 0.6 0.8 0.9 0.9 0.8 0.6 0.5 0.5 0.6 0.6 0.6 0.5 0.3 0.3 0.5 0.5 0.5 0.5 0.4 0.3 0.2 0.5 0.7 0.8 0.9 0.9 0.8 0.7 0.6 0.5 0.5 0.5 0.5 0.4 0.3 0.3 0.5 0.5 0.6 0.5 0.5 0.3 0.2 0.6 0.7 0.8 0.9 0.9 0.8 0.7 0.6 0.5 0.5 0.6 0.5 0.5 0.4 0.3 0.5 0.6 0.6 0.6 0.5 0.4 0.3 0.5 0.6 0.6 0.6 0.5 0.4 0.3 0.5 0.6 0.6 0.6 0.5 0.4 0.3 0.5 0.6 0.6 0.6 0.5 0.4 0.3 0.5 0.6 0.6 0.6 0.5 0.4 0.4 0.5 0.6 0.6 0.6 0.5 0.5 0.4 0.4 0.5 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.8 0.8 0.8 0.5 0.5 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.6 0.7 0.7 0.8 0.8 0.9 0.9 0.9 0.9 0.9 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.0 1.1 1.1 1.1 1.0 1.0 0.4 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.2 1.3 1.2 1.1 1.0 0.4 0.4 0.5 0.5 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.1 1.2 1.3 1.4 1.4 1.4 1.2 1.1 0.4 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.4 1.4 1.5 1.4 1.3 1.2 0.4 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.1 1.3 1.4 1.5 1.5 1.5 1.4 1.3 0.4 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.2 1.3 1.4 1.5 1.6 1.6 1.5 1.3 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.0 1.2 1.3 1.5 1.6 1.7 1.6 1.5 1.4 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.1 1.2 1.4 1.5 1.6 1.7 1.7 1.6 1.4 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1.1 1.2 1.4 1.5 1.7 1.7 1.7 1.6 1.4 0.3 0.4 0.4 0.5 0.5 0.6 0.7 0.7 0.8 1.0 1.1 1.3 1.4 1.6 1.7 1.8 1.8 1.6 1.4 0.4 0.4 0.5 0.5 0.6 0.7 0.7 0.9 1.0 1.1 1.3 1.4 1.6 1.7 1.8 1.8 1.6 1.5 0.4 0.4 0.5 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.3 1.4 1.6 1.7 1.8 1.8 1.6 1.4 0.4 0.4 0.5 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.3 1.4 1.6 1.7 1.7 1.7 1.6 1.4 0.4 0.5 0.5 0.5 0.6 0.7 0.7 0.9 1.0 1.1 1.3 1.4 1.6 1.7 1.7 1.7 1.6 1.4 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.8 0.9 1.1 1.2 1.4 1.5 1.6 1.6 1.6 1.5 1.3 0.5 0.5 0.5 0.6 0.6 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.4 1.5 1.5 1.5 1.4 1.2 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.4 1.2 1.1 0.6 0.6 0.6 0.6 0.5 0.5 0.6 0.6 0.7 0.7 0.8 0.9 1.0 1.1 1.2 1.2 1.1 0.9 0.6 0.6 0.6 0.6 0.5 0.5 0.6 0.6 0.6 0.6 0.5 0.4 0.6 0.6 0.6 0.6 0.5 0.4 0.6 0.6 0.6 0.6 0.5 0.4 0.2 0.6 0.6 0.6 0.5 0.5 0.4 0.2 0.6 0.6 0.6 0.5 0.4 0.4 0.1 0.1 0.6 0.6 0.6 0.5 0.4 0.3 0.1 0.1 0.5 0.6 0.5 0.5 0.3 0.3 0.1 0.1 0.1 0.5 0.5 0.5 0.4 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.1 0.1 0.1 0.5 0.5 0.5 0.4 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.1 0.1 0.1 0.1 0.4 0.4 0.4 0.4 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.1 0.1 0.1 0.1 0.1 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.1 0.1 0.1 0.1 0.1 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.5 0.5 0.5 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.6 0.6 0.5 0.5 0.5 0.6 0.7 0.7 0.7 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.7 0.6 0.6 0.6 0.6 0.7 0.8 0.9 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.7 0.7 0.7 0.7 0.7 0.9 1.0 1.0 1.0 1.0 0.9 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.9 0.9 0.9 0.8 0.8 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.8 1.0 1.1 1.1 1.1 1.0 0.9 0.7 0.7 0.7 0.8 0.9 0.9 0.9 0.9 1.0 1.0 0.9 0.9 0.8 0.8 0.8 0.7 0.7 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.8 1.0 1.2 1.2 1.1 1.0 0.8 0.7 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.0 0.9 0.9 0.8 0.8 0.7 0.7 0.7 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.8 1.0 1.2 1.2 1.2 1.1 0.9 0.7 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.0 0.9 0.8 0.8 0.8 0.8 0.7 0.7 0.6 0.6 0.7 0.7 0.7 0.7 0.8 1.0 1.2 1.2 1.2 1.1 0.9 0.7 0.7 0.7 0.8 0.9 1.0 1.0 1.0 1.1 1.1 1.1 1.0 1.0 1.0 0.9 0.9 0.8 0.8 0.7 0.7 0.7 0.7 0.7 0.7 0.8 1.0 1.2 1.2 1.2 1.2 0.9 0.8 0.8 0.8 0.9 1.0 1.0 0.9 0.8 0.8 0.7 0.7 0.7 0.8 1.0 1.1 1.2 1.1 1.2 1.0 0.8 0.8 0.9 1.0 1.2 1.1 1.0 0.9 0.9 0.8 0.7 0.7 0.8 0.9 1.1 1.1 1.1 1.2 1.0 0.8 0.8 0.9 1.0 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.7 0.8 0.9 1.0 1.1 1.0 1.2 1.0 0.8 0.8 0.9 1.0 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.7 0.7 0.9 1.0 1.0 1.0 1.2 1.0 0.8 0.8 0.8 1.0 1.3 1.2 1.1 1.0 0.9 0.7 0.7 0.6 0.7 0.8 0.9 0.9 0.9 1.1 0.9 0.7 0.7 0.7 0.9 1.1 1.1 1.0 0.9 0.8 0.7 0.6 0.6 0.6 0.7 0.8 0.8 0.8 1.1 0.9 0.7 0.7 0.7 0.8 1.0 0.9 0.8 0.8 0.7 0.6 0.6 0.5 0.6 0.7 0.7 0.8 0.7 1.1 0.8 0.7 0.6 0.7 0.8 0.9 1.0 1.0 1.1 1.1 1.1 1.1 1.0 1.0 0.9 0.9 0.9 0.8 0.7 0.6 0.6 0.6 0.6 0.5 0.5 0.5 0.6 0.6 0.7 0.6 1.0 0.8 0.6 0.6 0.6 0.7 0.8 0.8 0.9 0.9 1.0 1.0 1.0 0.9 0.9 0.8 0.8 0.7 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.9 0.7 0.6 0.6 0.6 0.6 0.7 0.7 0.8 0.8 0.9 0.9 0.9 0.8 0.8 0.7 0.7 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.8 0.7 0.6 0.5 0.6 0.6 0.7 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.7 0.7 0.6 0.5 0.5 0.5 0.5 0.4 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.5 0.7 0.7 0.8 0.8 0.7 0.7 0.7 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.1 0.2 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.2 0.3 0.4 0.4 0.4 0.4 0.4 0.2 0.3 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.5 0.5 0.3 0.3 0.2 0.5 0.5 0.5 0.4 0.4 0.3 0.3 0.3 0.3 0.6 0.6 0.5 0.5 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.4 24064 N E W M E X I C O C H R I S T O P H E R J. W I L L I A M S P R O F E S S I O NAL E N G I N E E R 9.10.2024 drawing scale: 3/16" = 1'-0" 9/11/2024 10:02:58 AM E200 ELECTRICAL PHOTOMETRIC PLAN 511 Paseo de Peralta Santa Fe, NM PERALTA'S WALK, LLC. PASEO NORTH N SCALE: 3/16" = 1'-0" ELECTRICAL PHOTOMETRIC PLAN 1 GENERAL NOTES: 1. ALL IMPROVEMENTS, UNLESS OTHERWISE MODIFIED IN THE PROJECT SPECIFICATIONS, SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE COSF STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION FOR THE CITY OF SANTA FE, NM., LATEST EDITION, EXCEPT WHERE OTHERWISE NOTED IN THE DRAWINGS. 2. THE CONTRACTOR AGREES SHALL ASSUME THE SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF PROJECT CONSTRUCTION, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR ENGINEER. 3. NO CHANGES SHALL BE MADE TO THESE PLANS WITHOUT THE WRITTEN APPROVAL OF THE OWNER, ENGINEER AND ALL APPROVAL SIGNATORIES. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION METHODS OR TECHNIQUES OR FOR THE PROSECUTION OF THE WORK AS SHOWN ON THESE PLANS. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTORS OR OTHER PERSONS PERFORMING ANY OF THE WORK OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH CONTRACT DOCUMENTS. 4. THE CONTRACTOR SHALL DESIGNATE AT LEAST ONE EMERGENCY CONTACT PERSON, AND SHALL PROVIDE TELEPHONE NUMBERS WHERE THIS PERSON CAN BE CONTACTED AT ANY TIME, INCLUDING WEEKENDS, HOLIDAYS AND AFTER HOURS. THIS INFORMATION SHALL BE PROVIDED TO THE OWNER AND THE ENGINEER. 5. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED CONSTRUCTION PERMITS FROM ALL JURISDICTIONAL AUTHORITIES PRIOR TO START OF CONSTRUCTION. PERMIT COSTS ARE INCIDENTAL TO BASE BID. 6. ALL WORK ON THIS PROJECT SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL LAWS, RULES AND REGULATIONS CONCERNING CONSTRUCTION SAFETY, HEALTH, AND ENVIRONMENTAL PROTECTION. 7. EXISTING SITE INFRASTRUCTURE WHICH ARE DAMAGED OR DISPLACED BY THE CONTRACTOR SHALL BE REMOVED AND REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S OWN EXPENSE. REPAIRS SHALL BE APPROVED BY THE OWNER PRIOR TO CONSTRUCTION OF THE REPAIRS. REPAIRS SHALL BE ACCEPTED BY THE OWNER PRIOR TO FINAL PAYMENT. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING, IN ADVANCE OF CONSTRUCTION OPERATIONS, IF OVERHEAD UTILITY LINES, SUPPORT STRUCTURES, POLES, GUYS, ETC. ARE AN OBSTRUCTION TO CONSTRUCTION OPERATIONS. IF ANY OBSTRUCTION IS EVIDENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE APPROPRIATE UTILITY OWNER TO REMOVE OR SUPPORT THE UTILITY OBSTRUCTION. ANY COST ASSOCIATED WITH THIS EFFORT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 9. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXCAVATE AND VERIFY THE HORIZONTAL AND VERTICAL LOCATIONS OF ALL UNDERGROUND UTILITY CONFLICTS. SHOULD A CONFLICT EXIST, THE CONTRACTOR SHALL NOTIFY THE ENGINEER SO THAT THE CONFLICT CAN BE RESOLVED WITH A MINIMUM AMOUNT OF DELAY. 10. WHEN ABUTTING NEW PAVEMENT TO EXISTING INTERSECTING STREETS THE EXISTING PAVEMENT SHALL BE SAW CUT TO A STRAIGHT LINE AT RIGHT ANGLES AND ANY BROKEN OR CRACKED PAVEMENT SHALL BE REMOVED. SAW CUTTING SHALL BE INCIDENTAL TO PAVING, THEREFORE, NO DIRECT PAYMENT WILL BE MADE FOR THE SAW CUTTING. 11. ANY PAVEMENT DISTURBED BY THE TRENCH SHALL BE REMOVED AND THE FULL SECTION OF PAVEMENT SHALL BE REPLACED. FOR THE PAVEMENT BEYOND THAT AREA DISTURBED BY THE EXCAVATED TRENCH, THE FOLLOWING APPLIES UNLESS OTHERWISE NOTED ON PLANS: IF ONLY ONE LANE IS DISTURBED BY TRENCHING, THE REMAINDER OF THE ONE ENTIRE LANE SHALL BE MILLED AND RESURFACED. IN A FOUR-LANE STREET, IF MORE THEN ONE LANE BUT LESS THEN HALF THE STREET IS AFFECTED, THEN THE REMAINDER OF HALF THE STREET (TWO LANES MINIMUM) SHALL BE MILLED AND RESURFACED. IF MORE THAN ONE-HALF OF ANY STREET WIDTH IS AFFECTED, THEN ALL PAVING IN THE STREET FROM CURB TO CURB SHALL BE MILLED AND RESURFACED. 12.DEWATERING DURING CONSTRUCTION IS CONSIDERED INCIDENTAL TO THE COST OF CONSTRUCTION EROSION CONTROL/ENVIRONMENTAL PROTECTION/STORM WATER POLLUTION PREVENTION PLAN: 1. THE CONTRACTOR SHALL CONFORM TO ALL CITY, COUNTY, STATE AND FEDERAL DUST AND EROSION CONTROL REGULATIONS. THE CONTRACTOR SHALL PREPARE AND OBTAIN ANY NECESSARY DUST OR EROSION CONTROL PERMITS FROM REGULATORY AGENCIES. 2. THE CONTRACTOR SHALL PROMPTLY REMOVE ANY MATERIAL EXCAVATED WITHIN THE PUBLIC RIGHT-OF-WAY TO KEEP IT FROM WASHING OFF THE PROJECT SITE. 3. THE CONTRACTOR SHALL ENSURE THAT NO SOIL ERODES FROM THE SITE ONTO OTHER PROPERTY BY CONSTRUCTING TEMPORARY EROSION CONTROL BERMS OR PLAN. INSTALLING SILT FENCES AT THE PROPERTY LINES. 4. THE CONTRACTOR SHALL MITIGATE EROSION OF TEMPORARY OR PERMANENT DIRT SWALES BY INSTALLING CHECK DAMS IN THE SWALES PERPENDICULAR TO THE DIRECTION OF FLOW. 5. THE CONTRACTOR SHALL WET THE SOIL AS NEEDED TO KEEP IT FROM BLOWING WATERING, AS REQUIRED FOR CONSTRUCTION AND DUST CONTROL, SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION AND NO MEASUREMENT OR PAYMENT SHALL BE MADE THEREFOR. CONSTRUCTION AREAS SHALL BE WATERED FOR DUST CONTROL IN COMPLIANCE WITH GOVERNMENT ORDINANCES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND SUPPLYING WATER AS REQUIRED. 6. ANY AREAS DISTURBED BY CONSTRUCTION AND NOT COVERED BY LANDSCAPING OR ANY IMPERVIOUS SURFACE SHALL BE REVEGETATED WITH NATIVE GRASS SEEDING. WHEN CONSTRUCTION ACTIVITIES CEASE AND EARTH DISTURBING ACTIVITIES WILL NOT RESUME WITHIN 14 DAYS, STABILIZATION MEASURES MUST BE INITIATED. UNLESS INDICATED OTHERWISE ON THESE PLANS OR ON THE LANDSCAPING PLAN, SEEDING SHALL BE NATIVE GRASS SEEDING PER SECTION 1012 OF THE COA STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 7. ALL WASTE PRODUCTS FROM THE CONSTRUCTION SITE, INCLUDING ITEMS DESIGNATED FOR REMOVAL, CONSTRUCTION WASTE, CONSTRUCTION EQUIPMENT WASTE PRODUCTS (OIL, GAS, TIRES, ETC.) GARBAGE, GRUBBING, EXCESS CUT MATERIAL, VEGETATIVE DEBRIS, ETC. SHALL BE APPROPRIATELY DISPOSED OF OFF-SITE AT NO ADDITIONAL COST TO THE OWNER. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN PERMITS REQUIRED FOR HAUL OR DISPOSAL OF WASTE PRODUCTS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE WASTE DISPOSAL SITE COMPLIES WITH GOVERNMENT REGULATIONS REGARDING THE ENVIRONMENT, ENDANGERED SPECIES AND ARCHAEOLOGICAL RESOURCES. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEANUP AND REPORTING OF SPILLS OF HAZARDOUS MATERIALS ASSOCIATED WITH THE CONSTRUCTION SITE. HAZARDOUS MATERIALS INCLUDE GASOLINE, DIESEL FUEL, MOTOR OIL, SOLVENTS, CHEMICALS, PAINTS, ETC. WHICH MAY BE A THREAT TO THE ENVIRONMENT. THE CONTRACTOR SHALL REPORT THE DISCOVERY OF PAST OR PRESENT SPILLS TO THE NEW MEXICO ENVIRONMENT DEPARTMENT EMERGENCY RESPONSE AT 1-(505)-827-9329. 9. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE REGULATIONS CONCERNING SURFACE AND UNDERGROUND WATER. CONTACT WITH SURFACE WATER BY CONSTRUCTION EQUIPMENT AND PERSONNEL SHALL BE MINIMIZED. EQUIPMENT MAINTENANCE AND REFUELING OPERATIONS SHALL BE PERFORMED IN AN ENVIRONMENTALLY SAFE MANNER IN COMPLIANCE WITH GOVERNMENT REGULATIONS. 10. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE REGULATIONS CONCERNING CONSTRUCTION NOISE AND HOURS OF OPERATION. 11. WHERE STORM INLETS ARE SUSCEPTIBLE TO IN FLOW OF SILT OR DEBRIS FROM CONSTRUCTION ACTIVITIES, PROTECTION SHALL BE INSTALLED ON THEIR UPSTREAM SIDE. CLEARING AND GRUBBING: 1. SCOPE: THIS SECTION GOVERNS THE FURNISHING OF ALL LABOR, EQUIPMENT, TOOLS AND MATERIALS AND THE PERFORMANCE OF ALL CLEARING, GRUBBING, AND DEMOLITION WITHIN THE LIMITS OF WORK AS DEFINED IN THIS SPECIFICATION, IN THE SPECIAL PROVISIONS OR AS SHOWN ON THE PLANS. 2. CLEARING: CLEARING SHALL CONSIST OF REMOVING ALL VEGETABLE MATTER SUCH AS TREES, BRUSH, DOWN TIMBER AND OTHER OBJECTIONABLE MATERIALS FOUND ON OR ABOVE THE SURFACE OF THE SITE. IT SHALL INCLUDE REMOVING BUILDINGS, FENCES, LUMBER, WASTE DUMPS AND TRASH AND THE SALVAGING OF SUCH MATERIALS AS MAY BE SPECIFIED AND DISPOSING OF THE DEBRIS. THE CONTRACTOR SHALL SCALP ALL EXCAVATION AND EMBANKMENT AREAS. SCALPING SHALL INCLUDE THE REMOVAL OF MATERIAL SUCH AS SOD, GRASS, RESIDUE OR AGRICULTURAL CROPS AND DECAYED VEGETABLE MATTER FROM THE SURFACE OF THE GROUND WITHOUT REMOVING MORE EARTH THAN IS NECESSARY. 3. GRUBBING: GRUBBING SHALL CONSIST OF REMOVING AND DISPOSING OF ALL VEGETABLE MATTER SUCH AS STUMPS, ROOTS, BURIED TREES AND BRUSH ENCOUNTERED BELOW THE SURFACE OF THE GROUND OR SUBGRADE, WHICHEVER IS LOWER, WHICH HAVE NOT BEEN INCLUDED IN SECTION 2101.2A ENTITLED “CLEARING”. IN ALL CASES OF GRUBBING, THE VEGETABLE MATTER SHALL BE REMOVED TO A MINIMUM DEPTH OF 12 INCHES (30.48CM) BELOW GROUND LINE OR SUBGRADE, WHICHEVER IS LOWER, EXCEPT AS PROVIDED IN SECTION 311000. WHEN DELETERIOUS MATERIALS ARE ENCOUNTERED BELOW GROUND LINE WHICH MAY BE DETRIMENTAL TO THE PROPOSED IMPROVEMENT, THESE SHALL BE REMOVED TO A DEPTH NECESSARY TO PROVIDE ADEQUATE SUPPORT FOR THE PROPOSED IMPROVEMENT. 4. DEMOLITION AND REMOVAL: THIS WORK SHALL CONSIST OF DEMOLISHING, REMOVING, AND DISPOSING OF ALL STRUCTURES AND IMPROVEMENTS WITHIN THE CONSTRUCTION LIMITS UNLESS INCLUDED IN OTHER ITEMS OF WORK AS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THIS WORK SHALL APPLY TO ALL STRUCTURES AND IMPROVEMENTS, WHETHER ON, ABOVE OR BELOW THE SURFACE OF THE GROUND OR SUBGRADE. DEMOLITION AND REMOVAL SHALL INCLUDE BUT NOT BE LIMITED TO ITEMS SUCH AS BUILDINGS, DRAINAGE STRUCTURES, PIPES, PAVEMENTS, FENCES, RETAINING WALLS, GUARD RAILS, AND SIGNS. ITEMS SUCH AS FENCES AND GUARD RAILS SHALL BE SALVAGED AND RELINQUISHED TO THE APPROPRIATE OWNER OR RELOCATED, WHERE INDICATED ON THE PLANS. RELOCATION OF SIGNS, FENCES, GUARD RAILS, ETC. SHALL BE CONSIDERED INCIDENTAL TO REMOVAL WORK EXCEPT WHERE SUCH RELOCATION IS LISTED SEPARATELY IN THE ITEMIZED PROPOSAL OF THE SPECIAL PROVISIONS. ALL PIPES WHICH ARE TO BE ABANDONED SHALL BE REMOVED UNLESS OTHERWISE SHOWN ON THE PLANS OR APPROVED BY THE ENGINEER. 5. TREES: VEGETABLE GROWTH 6 INCHES (15.24CM) IN DIAMETER AND LARGER, MEASURED 3 FEET (91.44CM) ABOVE GROUND SHALL BE CLASSIFIED AS A TREE. E. BRUSH: VEGETABLE GROWTH LESS THAN 6 INCHES (15.24CM) IN DIAMETER, MEASURED 3 FEET (91.44CM) ABOVE GROUND SHALL BE CLASSIFIED AS BRUSH. GEOTECHNICAL INVESTIGATION: 1. GEOTECHNICAL EXPLORATION, TESTING, AND ANALYSIS WILL ESTABLISH PARAMETERS REQUIRED IN THE ENGINEERING OF FOUNDATIONS. CRITERIA WILL BE ESTABLISHED TO PERMIT THE MOST ECONOMICAL DESIGN THAT IS COMPATIBLE WITH LIFE EXPECTANCY AND SERVICE OF STRUCTURES. 2. DESIGN LOADS FOR ALL STRUCTURES WILL BE DETERMINED IN ACCORDANCE WITH THE CRITERIA DESCRIBED BELOW, UNLESS THE APPLICABLE BUILDING CODE REQUIREMENTS ARE MORE STRINGENT. 3. VEHICLE LOADS: LOADS EXERTED ON ROADWAY PAVEMENTS, BURIED PIPING, BOX CULVERTS, AND EMBANKMENTS WILL BE REVIEWED AND SELECTED PRIOR TO DESIGN OF THE UNDERLYING ITEMS. TYPICALLY, HS20 LOADS WILL BE USED FOR THE DESIGN OF ROADWAY SUB GRADE. EQUIPMENT LOADING SUCH AS SCRAPERS (LOADED), CRAWLER CRANES, AND EQUIPMENT TRANSPORT TRAILERS COULD EXCEED THE TYPICAL HS20 LOADINGS. SUCH LOADS WILL BE CONSIDERED WHERE APPROPRIATE. 4. SITE ARRANGEMENT: THE SITE ARRANGEMENT WILL CONFORM TO APPLICABLE LAWS, REGULATIONS, AND ENVIRONMENTAL STANDARDS. THE PRINCIPLE ELEMENTS IN THE SELECTION OF SITE ARRANGEMENT CRITERIA ARE THE PHYSICAL SPACE REQUIREMENTS AND RELATIONSHIPS DICTATED BY EACH OF THE MAJOR SYSTEMS. DISTANCES BETWEEN VARIOUS SYSTEMS WILL BE MINIMIZED FOR ECONOMY. UTILITY INTERCONNECTIONS WILL BE OPTIMIZED AS MUCH AS PRACTICAL. SPILL CONTAINMENT MEASURES WILL BE PROVIDED. TREATMENT SYSTEMS WILL BE PROVIDED FOR FACILITY WASTEWATER STREAMS, IF REQUIRED, BEFORE DISCHARGE. SANITARY WASTEWATER WILL BE DISCHARGED TO AN ON-SITE LEACHING FIELD. INTERNAL ACCESS ROADS WILL BE PROVIDED. THE SITE ARRANGEMENT WILL BE DEVELOPED TO MINIMIZE FILL AND/OR EXCAVATION COSTS WHILE MAINTAINING EFFICIENCY OF PROJECT CONSTRUCTION, OPERATION, AND MAINTENANCE. THE SITE GRADING AND DRAINAGE PLAN WILL USE A SERIES OF ON-SITE LOCALIZED INFILTRATION AREAS. SHEET FLOW, WHICH FOLLOWS THE EXISTING NATURAL DRAINAGE COURSE, WILL DIRECT THE RUNOFF ACROSS THE SITE TO THE LOCALIZED INFILTRATION AREAS INCORPORATED INTO THE SITE GRADING AND DRAINAGE PLANS. THE USE OF LOW RUNOFF VELOCITIES AND INFILTRATION AREAS WILL ALLOW THE RUNOFF TO BE ABSORBED INTO THE GROUND. WASTEWATER THAT MAY CONTAIN OIL WILL BE ROUTED THROUGH AN OIL-WATER SEPARATOR. THE FOLLOWING CRITERIA WILL BE FOLLOWED REGARDING SITE INFRASTRUCTURE: - CULVERTS AND SANITARY SEWER MANHOLES WILL BE INSTALLED AS REQUIRED. - LOCATIONS AND REQUIREMENTS FOR FENCING OR WALLS WILL CONFORM TO APPLICABLE BUILDING CODES AND COUNTY ORDINANCES. 5. GRADING AND DRAINAGE THE SITE GRADING AND DRAINAGE SYSTEM WILL BE DESIGNED TO COMPLY WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS. THE GENERAL SITE GRADING WILL ESTABLISH A WORKING SURFACE FOR CONSTRUCTION AND OPERATING AREAS, PROVIDE POSITIVE DRAINAGE FROM BUILDINGS AND STRUCTURES, AND PROVIDE ADEQUATE SOIL COVERAGE FOR UNDERGROUND UTILITIES. ON-SITE DRAINAGE WILL BE ACCOMPLISHED THROUGH GRAVITY FLOW WHENEVER POSSIBLE. THE SURFACE DRAINAGE SYSTEM WILL CONSIST OF GENTLE SLOPES. THE BUILDINGS AND STRUCTURES WILL BE LOCATED WITH THE GROUND FLOOR ELEVATION A MINIMUM OF SIX INCHES ABOVE THE FINISHED GRADE. THE PREFERRED SLOPE OF THE GRADED AREAS AWAY FROM STRUCTURES WILL BE 1 PERCENT WITH A MINIMUM SLOPE OF 0.5 PERCENT. SITE DRAINAGE FACILITIES WILL BE DESIGNED FOR THE FLOW RESULTING FROM A 25-YEAR, 6-HOUR RAINFALL EVENT. TEMPORARY FACILITIES WILL GENERALLY BE DESIGNED FOR A 2-YEAR RAINFALL. ANY FACILITIES LOCATED WITHIN A FLOOD PLAIN WILL BE ELEVATED AND DESIGNED TO PREVENT FLOODING OF PERMANENT FACILITIES. EXCAVATION AND FILL EXCAVATION AND FILL WILL BE BALANCED TO THE MAXIMUM EXTENT POSSIBLE. - EXCAVATION : IN AREAS REQUIRING EXCAVATION, EARTH MATERIAL WILL BE REMOVED TO THE REQUIRED LINES AND GRADES. ANY UNDESIRABLE MATERIAL WILL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH APPLICABLE REGULATIONS. THE REMAINING IN-SITU MATERIAL WILL BE GRADED AND COMPACTED TO THE DEPTH AND DENSITY DETERMINED BY DETAILED DESIGN. EXCAVATED MATERIAL THAT MEETS THE DESIGN REQUIREMENTS WILL BE USED AS GENERAL SITE FILL WHERE POSSIBLE. - FILL : COMPACTED FILL MATERIAL WILL BE OBTAINED FROM ON SITE EXCAVATIONS TO THE MAXIMUM EXTENT POSSIBLE. THE MATERIAL WILL BE PLACED AND COMPACTED TO THE GRADES AND DENSITY DETERMINED BY THE DESIGN. BASED UPON THE SITE GEOTECHNICAL INVESTIGATION FINDINGS, COMPACTION WILL BE PROVIDED UNDER AND WITHIN FIVE FEET OF THE FOUNDATION FOOTPRINT. OPEN AREAS NOT SUPPORTING REFLECTOR FOUNDATIONS WILL BE SCARIFIED AND GRADED TO ACHIEVE HIGH SOIL PERMEABILITY. APPROXIMATELY SIX INCHES OF TOPSOIL WILL BE PLACED ON FILL IN ANY AREAS THAT ARE TO BE SEEDED OR OTHERWISE LANDSCAPED. b. DRAINAGE SWALES DRAINAGE SWALES WILL BE DESIGNED TO PROVIDE SLOW FLOW VELOCITIES AND TO ACCOMMODATE EXPECTED SITE RUNOFF AS WELL AS DIRECT AND CONTROL RUNOFF FROM ADJOINING PROPERTIES. c. STORM WATER DRAINAGE A STORM WATER DRAINAGE SYSTEM WILL BE DEVELOPED. DRAINAGE SWALES WILL BE USED ALONG THE PERIMETER TO CONTROL AND DIRECT STORM WATER RUNOFF FOR ABSORPTION INTO THE GROUND AS WELL AS DIRECT RUNOFF INTO THE EXISTING AREA DRAINAGE COURSE. d. PRE- AND POST-DEVELOPMENT RUNOFF CONDITIONS THE PEAK FLOW ASSOCIATED WITH THE 25-YEAR STORM EVENT AT THE SITE, BEFORE MODIFICATIONS (PREDEVELOPMENT), WILL BE COMPARED TO THE AFTER-CONSTRUCTION (POST-DEVELOPMENT) CONDITIONS. e. EROSION AND SEDIMENTATION CONTROL EROSION AND SEDIMENTATION CONTROL WILL BE PROVIDED TO RETAIN SEDIMENT ONSITE AND TO PREVENT VIOLATIONS OF WATER QUALITY STANDARDS. THE PROPOSED SITE DEVELOPMENT WILL SLIGHTLY ALTER THE LAND AREAS OF THE SITE. EXISTING, SPARSE VEGETATION WILL BE REMOVED AS REQUIRED DURING SITE PREPARATION. THE GENERAL PREPARATION OF THE OVERALL SITE WILL BE FOLLOWED BY EARTHMOVING ACTIVITIES. FINAL FINISH GRADING WILL BEGIN WHEN ALL OTHER GRADING OPERATIONS ARE COMPLETE. FINAL GRADING MAY INCLUDE SEEDING DISTURBED AREAS, SURFACED WITH CONCRETE, ASPHALT, OR CRUSHED AGGREGATE OR PROVIDED WITH A SOIL TREATMENT DESIGN TO LIMIT THE GROWTH OF GRASS AND WEEDS. TEMPORARY EROSION AND SEDIMENTATION CONTROL MEASURES USED DURING CONSTRUCTION WILL BE DESIGNED TO PREVENT SEDIMENTS FROM BEING DISPLACED AND CARRIED OFF-SITE BY STORM WATER RUNOFF. PRIOR TO BEGINNING EXCAVATION ACTIVITIES, A SILT FENCE OR STRAW BALES WILL BE INSTALLED ALONG THE PERIMETER OF THE PROJECT WORK AREAS WHERE RUNOFF TO OFFSITE AREAS COULD OCCUR. THE SILT FENCE WILL FILTER SEDIMENTS FROM CONSTRUCTION RUNOFF. DURING CONSTRUCTION, THE EXTENT OF EARTH DISTURBANCES WILL BE MINIMIZED AS MUCH AS PRACTICAL. DIVERSION DITCHES AND/OR BERMS WILL BE CONSTRUCTED AS NECESSARY TO DIVERT RUNOFF FROM OFF-SITE AREAS AROUND THE CONSTRUCTION SITE. TEMPORARY CONTROL MEASURES WILL BE MAINTAINED AS NECESSARY THROUGHOUT THE CONSTRUCTION PERIOD. PERMANENT EROSION AND SEDIMENTATION CONTROL MEASURES WITHIN THE PROJECT SITE WILL INCLUDE THE RUNOFF COLLECTION SYSTEM AND INFILTRATION SYSTEM, SURFACED TRAFFIC AND WORK AREAS, AND SEEDED NON-WORKING AREAS. THESE MEASURES WILL MINIMIZE THE POSSIBILITY OF ANY APPRECIABLE EROSION OF THE RESULTING SEDIMENTATION OCCURRING ON THE PROJECT SITE. 5. TRAFFIC AND TRANSPORTATION ACCESS WILL BE PROVIDED BY EXISTING ROADWAYS. ALL ROADS WILL BE APPROPRIATELY SURFACED DURING THE CONSTRUCTION PERIOD. PERIODIC WATERING OR APPLICATIONS OF A DUST PALLIATIVE MATERIAL WILL BE USED TO MINIMIZE DUST PROBLEMS. THE MINIMUM RADIUS TO THE INSIDE EDGE OF PAVEMENT (EOP) OR AGGREGATE SURFACE AT INTERSECTIONS OF THE ROAD WILL BE 20 FEET. 6. FENCING AND SECURITY SECURITY AND VISUAL SCREENING FENCING WILL BE PROVIDED AROUND THE PROJECT SITE. ACCESS TO THE PROJECT SITE WILL BE PROVIDED THROUGH A CONTROLLED ACCESS GATE. FENCING HEIGHTS WILL BE IN ACCORDANCE WITH APPLICABLE CODES, REGULATORY REQUIREMENTS AND VISUAL CONSIDERATIONS. UTILITIES-GENERAL NOTE: 1. IF ANY UTILITY LINES, PIPELINES OR UNDERGROUND UTILITY LINES ARE SHOWN ON THESE DRAWINGS, THEY ARE SHOWN IN AN APPROXIMATE LOCATION ONLY, AND LINES MAY EXIST WHERE NONE ARE SHOWN. THE LOCATION IS BASED UPON INFORMATION PROVIDED BY SURVEY PROVIDED BY CSTI, AND THIS INFORMATION MAY BE INCOMPLETE, OR OBSOLETE AT THE TIME OF CONSTRUCTION. THE ENGINEER HAS NOT UNDERTAKEN ANY FIELD VERIFICATION OF THESE LOCATIONS, LINE SIZES OR MATERIAL TYPE, MAKES NO REPRESENTATION THERETO, AND ASSUMES NO RESPONSIBILITY ITSELF OF THE LOCATION OF ANY UTILITY LINE, PIPELINE OR UNDERGROUND INSTALLATION IN OR NEAR THE AREA IN ADVANCE OF ANY DURING ANY EXCAVATION WORK. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES CAUSED BY ITS FAILURE TO LOCATE, IDENTIFY AND PRESERVE ANY AND ALL EXISTING UTILITIES, PIPELINES AND UNDERGROUND FACILITIES. IN PLANNING AND CONDUCTING EXCAVATIONS. THE CONTRACTOR SHALL COMPLY WITH ALL STATE STATUES, MUNICIPAL AND LOCAL ORDINANCES, RULES AND REGULATIONS, IF ANY, PERTAINING TO THE LOCATION OF THESE LINES AND FACILITIES. 2. THE CONTRACTOR SHALL NOTIFY NEW MEXICO ONE CALL, INC. AT 260-1990 AT LEAST TWO WORKING DAYS PRIOR TO STARTING WORK ON THIS PROJECT. GRADING: 1. THIS SECTION GOVERNS THE PERFORMANCE OF ALL WORK REQUIRED TO EXCAVATE, REMOVE, DISPOSE OR COMPACT ALL MATERIALS ENCOUNTERED WITHIN THE LIMITS OF THE PROJECT, AT THE LOCATIONS SHOWN ON THE PLANS, IN ACCORDANCE WITH THE REQUIREMENTS OF APPLICABLE SECTIONS OF THE GENERAL PROVISIONS AND COVENANTS, AND AS PROVIDED FOR IN THE SPECIAL PROVISIONS. 2. DEFINITIONS: 2.1. GRADING: GRADING AS USED HEREIN SHALL MEAN THE PERFORMANCE OF ALL EXCAVATION, EMBANKMENT, AND BACKFILL IN CONNECTION WITH THE CONSTRUCTION OF ALL IMPROVEMENTS 2.2. EXCAVATION: EXCAVATION IS DEFINED AS THE REMOVAL OF MATERIALS FROM THE CONSTRUCTION AREA TO THE LINES AND GRADES SHOWN ON THE PLANS. 2.3. UNCLASSIFIED EXCAVATION: UNCLASSIFIED EXCAVATION IS DEFINED AS THE REMOVAL OF ALL MATERIAL ENCOUNTERED REGARDLESS OF ITS NATURE. ALL MATERIAL EXCAVATED WILL BE CONSIDERED AS UNCLASSIFIED EXCAVATION UNLESS THE SPECIAL PROVISIONS SPECIFY CLASSIFIED MATERIALS. 2.4. ROCK EXCAVATION: ROCK EXCAVATION IS DEFINED AS THE REMOVAL OF ALL ROCK LEDGES 6 INCHES (15.24CM) OR MORE IN THICKNESS, AND DETACHED ROCK OR BOULDERS HAVING A VOLUME OF MORE THAN 1 ½ CUBIC YARDS (1.15 CUBIC METERS) AND SHALE OCCURRING IN ITS NATURAL STATE, HARD AND UN-WEATHERED. A ROCK LEDGE IS DEFINED AS A CONTINUOUS BODY OF ROCK WHICH MAY INCLUDE THIN INTERBEDDED SEAMS OF SHALE OR OTHER SOFT MATERIALS LESS THAN 12 INCHES (30.48CM) THICK. THE VERTICAL LIMIT OF EACH LEDGE SHALL BE DEFINED BY INTERBEDDED SEAMS OF SOFT MATERIALS 12 INCHES OR MORE IN THICKNESS. THE BEDS OF SOFT INTERBEDDED MATERIAL 12 INCHES (30.48CM) OR MORE IN THICKNESS SHALL NOT BE INCLUDED IN THE MEASUREMENT FOR “ROCK EXCAVATION” BUT SHALL BE INCLUDED IN THE MEASUREMENT FOR “EARTH EXCAVATION”. 2.5. EARTH EXCAVATION: EARTH EXCAVATION IS DEFINED AS THE REMOVAL OF ALL MATERIAL NOT DEFINED AS ROCK. 2.6. EMBANKMENT OR BACKFILL: EMBANKMENT OR BACKFILL IS DEFINED AS THE PLACING AND COMPACTING OF MATERIAL IN THE CONSTRUCTION AREA TO THE LINES AND GRADES SHOWN ON THE PLANS. 2.7. UNSUITABLE MATERIAL: UNSUITABLE MATERIAL IS DEFINED AS MUCK, FROZEN MATERIAL, ORGANIC MATERIAL, TOP SOIL, RUBBISH, AND ROCK WITH A MAXIMUM DIMENSION GREATER THAN 24 INCHES (60.96CM). 2.8. SUITABLE MATERIAL: SUITABLE MATERIAL IS DEFINED AS ENTIRELY IMPERISHABLE WITH THAT PORTION PASSING THE NO. 40 (425MM) SIEVE HAVING A LIQUID LIMIT NOT EXCEEDING 40 AND A PLASTIC INDEX NOT EXCEEDING 25, WHEN TESTED IN ACCORDANCE WITH ASTM D-423 AND D-424, RESPECTIVELY. 2.9. ROCK EMBANKMENT: MATERIAL FOR ROCK EMBANKMENT SHALL BE FREE OF UNSUITABLE MATERIAL AND SHALL CONTAIN, BY VOLUME, GREATER THAN 10 PERCENT ROCK OR GRAVEL HAVING A MAXIMUM DIMENSION GREATER THAN 3 INCHES (7.62CM) BUT NOT GREATER THAN 24 INCHES (60.96CM). 2.10. EARTH EMBANKMENT: MATERIAL FOR EARTH EMBANKMENT SHALL BE FREE OF UNSUITABLE MATERIAL AND SHALL, CONTAIN BY VOLUME, LESS THAN 10 PERCENT ROCK OR GRAVEL HAVING A MAXIMUM DIMENSION GREATER THAN 3 INCHES (7.62CM). 2.11. BORROW: BORROW IS DEFINED AS APPROVED MATERIAL EXCAVATED FROM AN AREA OUTSIDE OF THE PROJECT LIMITS AND REQUIRED FOR THE CONSTRUCTION OF THE EMBANKMENT. 2.12. WASTE: WASTE IS DEFINED AS EXCAVATION MATERIAL NOT USED IN THE EMBANKMENT AND DISPOSED OF OUTSIDE OF THE EMBANKMENT AREAS. 2.13. STRUCTURES: STRUCTURES AS USED HEREIN REFERS TO BRIDGES, CULVERTS, STORM SEWER AND/OR SANITARY APPUTENANCES, RETAINING WALLS AND SIMILAR CONSTRUCTION. 3. CONSTRUCTION DETAILS 3.1. THE CONTRACTOR SHALL ADHERE TO ANY AND ALL STATUTES REGARDING THE NOTIFICATION OF UTILITIES PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT-OF-WAY. RELOCATION OR PROTECTION OF ANY EXISTING UTILITIES LOCATED IN STREET RIGHT-OF-WAY SHALL BE GOVERNED BY SECTION 015000 AND 017300 OF THE GENERAL PROVISIONS. THE RELOCATION AND/OR PROTECTION OF ANY UTILITY THAT IS SHOWN ON THE PLANS, THAT LIES WITHIN A UTILITY EASEMENT AND IS ENDANGERED BY THIS CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 3.2. THE CONTRACTOR SHALL MAKE EVERY REASONABLE EFFORT TO PROTECT PRIVATE FACILITIES. THESE FACILITIES MAY NOT BE SHOWN ON THE PLANS. WHEN THESE FACILITIES ARE DISTURBED OR DAMAGED BY THE WORK, THE CONTRACTOR SHALL MAKE NECESSARY ARRANGEMENTS FOR REPAIRS TO THE FACILITIES FOR CONTINUOUS SERVICE PRIOR TO THE CLOSE OF THAT WORK DAY. 3.3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL PROPERTY LOT CORNERS AND CONTROL MONUMENTATION. SHOULD IT BE NECESSARY TO DISTURB ANY SUCH MONUMENT, WHETHER STAKE, PIN, BAR, DISK, BOX, OR OTHER, IT REMAINS THE RESPONSIBILITY OF THE CONTRACTOR TO REFERENCE SUCH MARKERS PRIOR TO REMOVAL, RESET THEM, AND FILE SUCH RELOCATIONS OR MONUMENTATION DOCUMENTS AS THE LAW MAY REQUIRE. ANY SUCH REFERENCES, REMOVAL, REPLACEMENT AND CERTIFICATION OF MONUMENTS SHALL BE PERFORMED BY A REGISTERED LICENSED SURVEYOR. A COPY OF ALL SUCH CERTIFICATION DOCUMENTS SHALL BE PROVIDED TO THE ENGINEER PRIOR TO FINAL PAYMENT. ANY MONUMENT DESTROYED OR IMPROPERLY RESET BY THE CONTRACTOR MAY BE REPLACED BY THE ENGINEER TO THE STANDARDS REQUIRED BY LAW AT THE EXPENSE OF THE CONTRACTOR. 3.4. GRADING, EXCAVATION, AND BACKFILLING FOR ALL IMPROVEMENTS, SHALL BE MADE TO THE LINES, GRADES, AND CROSS SECTIONS INDICATED BY THE PLANS. 9. BASE COARSE: CLASS 2 AGGREGATE BASE SHALL BE PLACED AFTER SITE GRADING ACTIVITIES ARE AT SUBSTANTIAL COMPLETION AND CONSIST OF THE FOLLOWING PROPERTIES: A) CLASS 2 AGGREGATE BASE SHALL BE FREE OF VEGETABLE MATTER AND OTHER DELETERIOUS SUBSTANCES. COARSE AGGREGATE, MATERIAL CONTAINED ON THE No. 4 SEIVE, SHALL CONSIST OF MATERIAL OF WHICH 25 PERCENT BY WEIGHT SHALL BE CRUSHED PARTICLES. CLASS 2 AGGREGATE BASE SHALL CONFORM TO ONE OF THE FOLLOWING GRADINGS, DETERMINED IN ACCORDANCE WITH ASTM C136 SPECIFICATIONS: PERCENT PASSING SIEVES SIEVE SIZE 1 2 INCH MAXIMUM 3 4 INCH MAXIMUM 2 INCH 100 ----- 1 1 2 INCH 90-100 ----- 1 INCH ----- 100 3 4 INCH 50-85 90-100 No. 4 25-45 35-55 No. 30 10-25 10-30 No. 200 2-9 3-9 B) CLASS 2 AGGREGATE BASE SHALL CONFORM TO THE FOLLOWING ADDITIONAL REQUIREMENTS: ASTM TEST TESTS METHOD REQUIREMENTS RESISTANCE (R-VALUE) D2844 78 MIN. SAND EQUIVALENT D2419 30 MIN. DURABILITY INDEX D3744 35 MIN. 10. ASPHALT PAVING 10.1. ASPHALT PAVING SHALL CONFORM TO STANDARD DIVISION SPECIFICATIONS, DIVISION 40 - ASPHALT PAVING. AVAILABLE UPON REQUEST TO THE ENGINEER. PAVING SHALL BE A MINIMUM OF 3" IN THICKNESS AND APPLIED OVER A CLASS 2 AGGREGATE BASE COARSE AS DESCRIBED ABOVE. 6. CONSTRUCTION DETAILS 6.1. LIMITS OF WORK: THE LIMITS FOR CLEARING, GRUBBING, AND DEMOLITION SHALL EXTEND TO THE CONSTRUCTION LIMITS UNLESS OTHERWISE SHOWN ON THE PLANS. 6.2. PROTECTION OF GREENERY, EXISTING STRUCTURES AND PRIVATE FACILITIES: THE PLANS WILL DESIGNATE TREES, SHRUBS OR OTHER PLANTS THAT ARE TO BE SAVED AND THE CONTRACTOR WILL TAKE NECESSARY STEPS TO PROTECT THIS GREENERY. TREES MAY BE PRUNED, UPON PRIOR APPROVAL OF THE ENGINEER, BUT ONLY IN ACCORDANCE WITH THE BEST PRACTICES OF ARBORICULTURE IN RESPECT TO THE INDIVIDUAL SPECIES WITH DUE REGARD TO THEIR NATURAL FORM AND GROWTH CHARACTERISTICS. EXISTING STRUCTURES WITHIN OR ADJACENT TO THE CONSTRUCTION LIMITS THAT ARE NOT TO BE REMOVED OR DEMOLISHED, SHALL BE PROTECTED BY THE CONTRACTOR DURING HIS CONSTRUCTION. ANY PRIVATE FACILITIES SUCH AS HOUSE SEWER LATERALS WHICH ARE DISTURBED OR DAMAGED BY THE CONTRACTOR'S WORK, SHALL BE REPAIRED BY THE CONTRACTOR PRIOR TO THE CLOSE OF THE WORK DAY. THIS REPAIR SHALL BE MADE IN A MANNER SUFFICIENT TO RESTORE UTILITY SERVICE TO THAT PROPERTY. 6.3. EMBANKMENT AREAS: WHEN UNDISTURBED STUMPS AND ROOTS ARE ENCOUNTERED WHERE THE FILL DEPTH WILL EXCEED 3 FEET (91.44CM), THE STUMPS AND ROOTS MAY BE LEFT IN PLACE PROVIDED THEY DO NOT EXTEND MORE THAN 3 INCHES (7.62CM) ABOVE THE ORIGINAL GROUND LINE. 6.4. BORROW AREAS: ALL STUMPS, ROOTS AND OTHER OBJECTIONABLE MATTER SHALL BE REMOVED FROM THE BORROW MATERIAL USED FOR EMBANKMENT OR FILL. THE BORROW AREA SHALL BE LEFT IN A WELL DRAINED AND SMOOTH CONDITION. 6.5. BACKFILLING THE SITE: ALL TRENCHES, HOLES, PITS, AND BASEMENT AREAS RESULTING FROM THE OPERATIONS OF CLEARING, GRUBBING, DEMOLITION AND REMOVAL ON THE SITE, SHALL BE BACKFILLED WITH SUITABLE MATERIAL PLACED AND COMPACTED IN CONFORMANCE WITH SECTION 311000. 6.6. DISPOSAL OF MATERIALS: ALL MATERIALS WITH THE EXCEPTION OF THOSE WHICH ARE DESIGNATED FOR SALVAGE OR WHICH ARE USED IN THE EMBANKMENT IN CONFORMANCE WITH THIS SPECIFICATION, SHALL BECOME THE CONTRACTOR'S PROPERTY AND SHALL BE DISPOSED OF BY HIM, OUTSIDE THE PROJECT LIMITS. 3.5. IN ADDITION, TO ANY EROSION CONTROL MEASURES SHOWN ON THE PLANS, THE CONTRACTOR SHALL SCHEDULE AND CONDUCT HIS OPERATION IN SUCH A MANNER AND SHALL PROVIDE ANY NECESSARY CONTROL FACILITIES TO PROTECT DOWNSTREAM AND ADJACENT PROPERTIES FROM POLLUTION, SEDIMENTATION, OR EROSION CAUSED BY THE GRADING OPERATIONS. ANY POLLUTION OR DAMAGE OCCURRING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 3.6. DURING CONSTRUCTION, THE GRADED AREA SHALL BE MAINTAINED BY THE CONTRACTOR IN SUCH CONDITION THAT IT WILL BE WELL DRAINED AT ALL TIMES. ROADWAY DITCHES, CHANNEL CHANGES, INLET AND OUTLET DITCHES AND OTHER DITCHES IN CONNECTION WITH THE ROADWAY SHALL BE CUT AND MAINTAINED TO THE REQUIRED CROSS SECTION. ALL DRAINAGE WORK SHALL BE PERFORMED IN PROPER SEQUENCE WITH OTHER OPERATIONS. ALL DITCHES AND CHANNELS SHALL BE KEPT FREE OF DEBRIS OR OBSTRUCTIONS. 4. EXCAVATION 4.1 THIS SECTION GOVERNS THE EXCAVATION FOR ALL IMPROVEMENTS. 4.2. ALL SUITABLE MATERIAL REMOVED BY EXCAVATION SHALL BE USED AS FAR AS PRACTICABLE IN THE FORMATION OF EMBANKMENT AS REQUIRED TO COMPLETE THE WORK. THE CONTRACTOR SHALL SORT ALL EXCAVATED MATERIAL AND STOCKPILE WHEN NECESSARY, SO AS TO PROVIDE SUITABLE MATERIALS FOR EMBANKMENTS. 4.3. AFTER REMOVAL OF THE ROADWAY EXCAVATION MATERIAL TO THE REQUIRED SECTION, ALL MATERIAL BETWEEN LINES 1 FOOT (30.48CM) OUTSIDE OF THE CURBS AND WITHIN THE TOP 6 INCHES (15.24CM) OF THE SUBGRADE SHALL BE COMPACTED TO 95 PERCENT OF MAXIMUM DENSITY FOR THE MATERIAL AS DEFINED IN SECTION 2102.6E. D. ROCK ENCOUNTERED WITHIN THE FULL WIDTH OF THE ROADWAY, TOE OF SLOPE TO TOE OF SLOPE, SHALL BE UNDERGRADED TO AN ELEVATION OF 6 INCHES (15.24CM) BELOW THE FINISHED SUBGRADE ELEVATION. CARE SHALL BE TAKEN TO AVOID OVERSHOOTING WHEN BLASTING. ROCK SHALL BE REMOVED IN SUCH A MANNER AS TO LEAVE NO EXCESSIVE WATER POCKETS IN THE SURFACE. 4.4 AREAS OF UNDERGRADING OR OVERBREAK IN ROCK BETWEEN LINES 1 FOOT (30.48CM) OUTSIDE OF THE CURBS SHALL BE BACKFILLED WITH SPALLS, ROCK FRAGMENTS OR A GRANULAR TYPE MATERIAL. BACKFILL MATERIALS SHALL HAVE A PLASTICITY INDEX NOT TO EXCEED 10 AND A GRADATION SUCH THAT AT LEAST 50 PERCENT OF THE MATERIAL WILL BE RETAINED ON THE NO. 4 (4.75MM) SIEVE. 5. UNDERGRADING 5.1. WHERE MATERIALS ARE ENCOUNTERED WHICH ARE DEEMED AS UNSUITABLE BY THE ENGINEER FOR USE IN THE WORK, THEY SHALL BE REMOVED TO THE DEPTH AND LIMIT AS ORDERED BY THE ENGINEER. AREAS UNDERGRADED SHALL BE BACKFILLED WITH ONE OF THE FOLLOWING MATERIALS: 5.2. ROCK FRAGMENTS OR SPALLS. 5.3. A GRANULAR TYPE MATERIAL HAVING A PLASTICITY INDEX NOT TO EXCEED 10 AND A GRADATION SUCH THAT AT LEAST 50 PERCENT OF THE MATERIAL WILL BE RETAINED ON THE NO. 4 (4.75MM) SIEVE AND NOT MORE THAN 40 PERCENT WILL PASS THE NO. 10 (2.00MM) SIEVE. D. A MATERIAL MEETING THE REQUIREMENTS OF SECTION 2102.2C 6. EMBANKMENT 6.1. THIS SECTION GOVERNS EMBANKMENT FOR ALL IMPROVEMENTS. THE EMBANKMENTS SHALL BE CONSTRUCTED USING SUITABLE MATERIALS, AS HEREIN DEFINED, PROCURED FROM EXCAVATIONS MADE ON THE PROJECT SITE OR FROM BORROW AREAS AS REQUIRED TO COMPLETE THE GRADING WORK. 6.2. STARTING THE EMBANKMENT: WHERE EMBANKMENTS, REGARDLESS OF HEIGHT, ARE PLACED AGAINST HILLSIDES OR EXISTING EMBANKMENTS, EITHER OF WHICH HAVE A SLOPE STEEPER THAT 1 VERTICAL TO 4 HORIZONTAL, THE EXISTING SLOPE SHALL BE BENCHED OR STEPPED IN APPROXIMATELY 24 INCH (60.96CM) RISES AS THE NEW FILL IS BROUGHT UP IN 12 INCH MAXIMUM (30.48CM) LAYERS OR LIFTS. THE MATERIAL BLADED OUT, THE BOTTOM OF THE AREA CUT INTO, AND THE EMBANKMENT MATERIAL BEING PLACED, SHALL BE COMPACTED TO THE REQUIRED DENSITY. MATERIAL CUT OUT, BLADED INTO PLACE AND COMPACTED SHALL NOT BE MEASURED AND PAID FOR DIRECTLY BUT WILL BE CONSIDERED AS INCIDENTAL WORK. THE EXISTING SURFACE UPON WHICH EMBANKMENT MATERIAL IS TO BE PLACED SHALL HAVE ALL UNSTABLE AND UNSUITABLE MATERIAL REMOVED BEFORE STARTING THE EMBANKMENT WORK. WHERE EMBANKMENTS 2 FEET (60.96CM) OR LESS IN DEPTH ARE TO BE PLACED ON AREAS COVERED BY EXISTING PAVEMENT, THE EXISTING PAVEMENT SHALL BE REMOVED AND THE CLEARED GROUND SURFACE SHALL BE COMPACTED TO THE SPECIFIED DENSITY. WHERE EMBANKMENTS GREATER THAN 2 FEET (60.96CM) IN DEPTH ARE TO BE PLACED ON AREAS COVERED BY EXISTING PAVEMENT, THE EXISTING PAVEMENT SHALL BE BROKEN INTO PIECES NO LARGER THAN 24 INCHES (60.96CM) MAXIMUM DIMENSION, LEFT IN PLACE AND THE EMBANKMENT STARRED THEREON. 6.3. PLACING EARTH EMBANKMENT: EARTH SHALL BE PLACED IN SUCCESSIVE HORIZONTAL LAYERS DISTRIBUTED UNIFORMLY OVER THE FULL WIDTH OF THE EMBANKMENT AREA. EACH LAYER OF MATERIAL SHALL NOT EXCEED 12 INCHES MAXIMUM (30.48CM) IN THICKNESS (LOOSE STATE) AND SHALL BE COMPACTED TO NOT LESS THAN THE REQUIRED DENSITY BEFORE THE NEXT LAYER IS PLACED THEREON. AS THE COMPACTION OF EACH LAYER PROGRESSES, CONTINUOUS BLADING, OR DOZING WILL BE REQUIRED TO LEVEL THE SURFACE AND TO INSURE UNIFORM COMPACTION. EMBANKMENT CONSTRUCTION SHALL NOT BE PERFORMED WHEN MATERIAL CONTAINS FROST, IS FROZEN OR IS SNOW COVERED. 6.4. PLACING EARTH AND ROCK EMBANKMENT: WHEN EARTH AND STONE OR ROCK FRAGMENTS ARE MIXED IN THE EMBANKMENT, ALL STONES OR ROCK FRAGMENTS EXCEEDING THE THICKNESS OF THE COMPACTED LIFT SHALL BE DISPOSED OF BY BEING INCORPORATED INTO THE EMBANKMENT OUTSIDE THE LIMIT OF THE PROPOSED SURFACED AREAS. THE THICKNESS OF THE LAYER IN THESE AREAS MAY BE INCREASED IF NECESSARY TO ACCOMMODATE THE ROCKS, BUT SHALL NOT EXCEED 15 INCHES (38.10CM) IN THICKNESS (LOOSE STATE). THE STONES OR ROCK FRAGMENTS ARE TO BE PLACED SO THERE WILL BE NO NESTING. 6.5. CONSOLIDATED ROCK EMBANKMENT: WHEN THE EXCAVATED MATERIAL CONSISTS PREDOMINANTLY OF STONE OR ROCK FRAGMENTS OF SUCH SIZE THAT THE MATERIAL CANNOT BE PLACED IN LAYERS OF THE THICKNESS PRESCRIBED, SUCH MATERIAL SHALL BE PLACED IN THE EMBANKMENT IN LAYERS HAVING A THICKNESS OF THE APPROXIMATE AVERAGE SIZE OF THE LARGER ROCKS BUT NOT TO EXCEED 24 INCH (60.96CM). ROCKS OR BOULDERS TOO LARGE TO PERMIT PLACING IN A 24 INCH (60.96CM) LAYER SHALL BE REDUCED IN SIZE AS NECESSARY TO PERMIT PLACEMENT. ROCK SHALL NOT BE DUMPED IN PLACE BUT SHALL BE DISTRIBUTED BY BLADING OR DOZING IN A MANNER TO INSURE PROPER PLACEMENT IN FINAL POSITION IN THE EMBANKMENT. THE SPALLS AND SMALLER STONE FRAGMENTS SHALL BE LEFT ON THE SURFACE OF EACH LAYER AS FORMED. EACH LAYER SHALL BE THOROUGHLY CONSOLIDATED BEFORE THE NEXT LAYER IS PLACED. THE TOP 12 INCHES (30.48CM) OF THE EMBANKMENT SHALL NOT CONTAIN MATERIAL HAVING A MAXIMUM DIMENSION GREATER THAN 3 INCHES (7.62CM). THE ROCK FRAGMENTS OR CRUSHED STONE SHALL BE WELL GRADED TO FORM A DENSE MASS WHEN COMPACTED. 6.6. COMPACTING THE EMBANKMENT: BEFORE PLACING ANY EMBANKMENT, THE SURFACE OF THE EXISTING GROUND SHALL BE PREPARED AS HERETOFORE SPECIFIED, MOISTENED AS REQUIRED, AND THE TOP 6 INCHES (15.24CM) COMPACTED TO A DENSITY OF 90 PERCENT AS PRESCRIBED BY THE FOLLOWING PARAGRAPH: ALL EMBANKMENT SHALL BE COMPACTED TO A DENSITY OF AT LEAST 90 PERCENT OF THE MAXIMUM DENSITY FOR THE MATERIAL USED AS DETERMINED BY ASTM D-698 AND WITHIN A TOLERANCE OF MINUS 3 PERCENT AND PLUS 2 PERCENT OF THE OPTIMUM MOISTURE AT MAXIMUM DENSITY AS DETERMINED BY THE MOISTURE DENSITY CURVE OBTAINED. IN ADDITION TO THE ABOVE REQUIRED COMPACTION, THE SUBGRADE BETWEEN LINES 1 FOOT (30.48CM) OUTSIDE OF THE CURBS AND WITHIN THE TOP 6 INCHES (15.24CM) OF THE SUBGRADE SHALL BE COMPACTED TO A DENSITY OF AT LEAST 95 PERCENT OF THE MAXIMUM DENSITY FOR MATERIAL USED AS DETERMINED BY ASTM D-698 AND WITH A TOLERANCE OF MINUS 3 PERCENT AND PLUS 2 PERCENT OF THE OPTIMUM MOISTURE AT MAXIMUM DENSITY AS DETERMINED BY THE MOISTURE DENSITY CURVE OBTAINED. ALL WORK INVOLVED IN EITHER ADDING MOISTURE TO OR REMOVING MOISTURE FROM EMBANKMENT MATERIALS TO WITHIN THESE MOISTURE LIMITS SHALL BE CONSIDERED INCIDENTAL TO THE COMPLETION OF THE GRADING OPERATION. 6.7. MOISTURE - DENSITY DETERMINATION: IN-PLACE DENSITY AND MOISTURE CONTENT OF THE EMBANKMENT WILL BE DETERMINED BY THE STANDARD METHOD OF TEST FOR DENSITY OF SOIL IN PLACE BY THE SAND-CONE METHOD, ASTM D1556; OR BY THE RUBBER BALLOON METHOD, ASTM D-2167; OR BY NUCLEAR METHODS, ASTM D-2922. 7. FINISHING 7.1. IN AREAS WHERE SODDING OR SEEDING IS PROPOSED, THE UPPER 12 INCHES (30.48CM) OF THE SURFACE AREA SHALL BE EARTH MATERIAL. THE TOP 6 INCHES (15.24CM) SHALL BE SUITABLE FOR SUSTAINING GRASS. 7.2. EXCEPT WHERE OTHER PERMIT OR UTILITY WORK IS IN PROGRESS, THE GRADED SURFACE SHALL BE MADE FREE OF ROCK, CONCRETE, AND BRICK, OR FRAGMENTS THEREOF, OR RUBBISH AND SHALL BE FINISHED TO THE LINES, GRADES, AND CROSS SECTION INDICATED ON THE PLANS, INCLUDING SHOULDER, BERM AND SIDEWALK SPACES. 7.3. THE CONTRACTOR SHALL REPAIR ANY DAMAGED SURFACE, AND SHALL NOT USE ANY FINISHING EQUIPMENT THAT WILL LEAVE A MARRED SURFACE. WHEN THE SUBGRADE PREPARATION IS INCLUDED AS A PART OF THE FINISHING, THE WORK SHALL BE ACCOMPLISHED ACCORDING TO THE REQUIREMENTS OF SECTION 312000, AND SHALL BE CONSIDERED INCIDENTAL TO FINISHING THE GRADING WORK. 8. CLEANUP 8.1. CLEANUP SHALL FOLLOW THE WORK PROGRESSIVELY AND FINAL CLEAN-UP SHALL FOLLOW IMMEDIATELY BEHIND THE FINISHING. THE CONTRACTOR SHALL REMOVE FROM THE SITE OF THE WORK ALL EQUIPMENT, TOOLS AND DISCARDED MATERIALS, AND OTHER CONSTRUCTION ITEMS. THE ENTIRE RIGHT-OF-WAY OR EASEMENT SHALL BE LEFT IN A FINISHED AND NEAT CONDITION. CLEANUP SHALL BE CONSIDERED AS INCIDENTAL TO THE COMPLETION OF GRADING WORK. ngineering & Design Santa Fe, New Mexico 87502e l P.O. Box 5861 (505) 470-2895 www.rebelengineeringnm.com R B E Structural, Civil & Architectural Engineering . Santa Fe New Mexico Grading and Drainage Notes Preliminary C-1 Grading and Drainage Plan Preliminary 507 & 511 Paseo de Peralta DRIVEWAY CROSS SECTION 2/C3 DRIVEWAY CROSS SECTION 3/C3 507 PORTAL & LANDSCAPE AREAS 507 LANDSCAPE AREAS & TRASH RECEPTICAL, SEE ARCH. GENERAL NOTES: 1. ALL UTILITY CONNECTIONS; GAS, ELECTRIC, WATER AND SEWER ARE TO BE CONNECTED TO EXISTING UTILITY STUBS LOCATED ON OR IMMEDIATELY ADJACENT TO THE SITE. 2. EXISTING RETAINING WALLS WITHIN THE 511 PASEO DE PERALTA PROPERTY SHALL BE REMOVED TO ACCOMMODATE NEW CONSTRUCTION. EXISTING WET WELL ON THE SITE SHALL BE FILLED IN OR REMOVED AT THE CONTRACTORS DISCRETION. PORTAL PORTAL PORTAL EL = 0'-0" 6965.50' EL = -1'-4" 6964.17' EL = -2'-4" 6963.17' EL = 0'-0" 6965.50' EL = 0'-0" 6965.50' EL = +2'-0" 6967.50' EL = 4'-0" 6969.50' EL = 5'-6" 6971.00' EL = +2'-0" 6967.50' EL = -1'-4" 6964.17' EL = 0'-0" 6965.50' EL = 0'-0" 6965.50' EL = -2'-4" 6963.17' EL = -2'-3" 6963.25 EL = 0'-0" 6963.00' EL = 0'-0" 6963.00' NORTH EAST RETENTION POND,CAPACITY 976 FT3 @ 1.5' DEPTH GRADING AND DRAINAGE PLAN SCALE: 1: 10 NEW RETAINING WALL, SEE SECTION 3/C4. DO NOT DISTURB EXISTING WALL NEW RETAINING WALL, SEE SECTION 3/C4. DO NOT DISTURB EXISTING WALL TRENCH DRAINS & WET WELL, SEE DETAILS 1/C5 - 4/C5 507 LANDSCAPE AREAS 507 LANDSCAPE AREAS 507 LANDSCAPE AREAS EXIST. SIDEWALK EXISTING RETAINING WALL TO REMAIN, DO NOT DISTURB EXISTING RETAINING WALL & BUTTRESS TO REMAIN YARD WALL, HEIGHT PER ARCH., SEE DETAIL 7/C3 YARD WALL ALONG EXISTING CUT FACE, DO NOT DISTURB EXISTING BLOCK WALL. HEIGHT OF NEW WALL AND BOTTOM OF FOOTING TO BE FIELD ADJUSTED, SEE DETAIL 3/C4 POND OVERFLOW WILL DRAIN TO TRENCH DRAINS AND TO LOWER WET WELL 0+00 0+20 0+40 0+60 0+80 0+90 0+00 0+20 0+40 0+60 0+65 0+00 0+20 0+40 0+60 0+65 0+00 0+20 0+40 0+46 0+00 0+20 0+40 0+46 6965 6970 6970 6970 6965 6963 EL = 0'-0" 6963.00 RAMP @ 7% EL = -0'-6" 6962.50 6962.45 6962.5 6962.5 RAMP @ 7% INTERNAL ROOF DRAINS W/ COLLECTION BASIN AND 4" PVC DRAIN LINE TO CISTERN, TYP. SEE DETAIL 2/C4 NORTH OVERFLOW & RETENTION POND 1, CAPACITY = 170 FT3 @ 1' DEPTH NORTH OVERFLOW & RETENTION POND 2 CAPACITY = 311 FT3 @ 1' DEPTH 511 LANDSCAPE AREAS511 LANDSCAPE AREAS, SEE LANDSCAPE PLANS 0+00 0+20 0+40 0+45 S44°10'59"W 77.41' 39.49' S67°11'55"W N44°52'22"W 31.53' S19°25'09"W 39.25' 78.11' S71°13'23"E S65°32'02"E 56.58' 43.51' S56°59'19"E 92.80' N51°01'56"W 127.99' S44°10'59"W 77.41' 39.49' S67°11'55"W N44°52'22"W 31.53' S19°25'09"W 39.25' 78.11' S71°13'23"E S65°32'02"E 56.58' 43.51' S56°59'19"E S40°13'21"W 92.80' N51°01'56"W 127.99' MARKED PATHWAY MARKED PATHWAY DRIVEWAY CROSS SECTION 1/C3 DRIVEWAY CROSS SECTION 5/C3 DRIVEWAY CROSS SECTION 4/C3 DRIVEWAY/ENTRY RAMP CROSS SECTION 6/C3 8000 GALLON CAPACITY CISTERN SEE DETAILS, THIS SHEET 507 ROOF TOP COLLECTION 192 LIN. FT. OF 4" SCH 40 DRAIN PIPE IN TRENCH TO CISTERN CISTERN OVERFLOW TO WET WELL 6963.0 6962.9 6963.1 6962.0 6963.2 6962.3 6962.7 6962.5 6962.5 6962.0 6962.3 21.75' OF 4"Ø SCH 40 PCV DRAIN PIPE FROM DRAIN TO NE RETENTION POND PARAPET DRAINS TO LOWER ROOF DRIP EDGES, TYP. SEE ARCH. ROOF PLAN INTERNAL ROOF DRAINS TO COLLECTION BASIN AND TO RETENTION AREAS, SEE DETAIL 2/C4, TYP. INTERNAL ROOF DRAINS TO COLLECTION BASIN AND TO RETENTION AREAS, SEE DETAIL 2/C4, TYP. PARALLEL CURB RAMP, REFER TO DETAIL 6/C3 FOR ADDITIONAL INFORMATION INTERNAL ROOF DRAIN, TYP. ESTIMATED SITE SOIL QUANTITIES (CUT AND FILL COMPACTION FACTORS ARE 1.00 FOR THESE QUANTITIES AND BASED UPON EXISTING SURVEY COMPARED TO PROPOSED FININSHED GRADES) CUT: 2992.44 YD³ FILL: 83.72 YD³ NET: 2908.72 YD³ (CUT) YARD WALL, HEIGHT PER LANDSCAPE ARCH., SEE DETAIL 7/C3 PARALLEL CURB RAMP, REFER TO NMDOT STANDARD DRAWING 608-001-3 507 PdP RENTENTION AREA, CAPACITY @ 6" DEPTH = 120 FT3 SEE LANDSCAPE DRAWINGS FOR SURFACE TREATMENT 0+00 0+25 0+50 0+75 1+00 1+25 1+50 1+62 NEW RETAINING WALL, SEE SECTION 3/C4. DO NOT DISTURB EXISTING WALL ALIGNMENT THRU NORTH POND CL, SEE PROFILE 6/C5 507 ROOF TOP COLLECTION 192 LIN. FT. OF 4" SCH 40 DRAIN PIPE IN TRENCH TO CISTERN ROCK BERM, SEE DETAILS THIS SHEET ROCK BERM, SEE DETAILS THIS SHEET BURIED WATER STORAGE TANK (XERXES 8000 GALLON CAPACITY TANK SHOWN, EQUIVALENT ACCEPTABLE) NOTE: 1. PRIMARY USE OF WATER HARVESTING TANK IS TO PROVIDE IRRIGATION FOR LANDSCAPING PURPOSES. OUTFLOW FROM THE UNDERGROUND WATER TANK SHOULD BE PROVIDED BY A SUBMERSIBLE PUMP SYSTEM LOCATED WITHIN THE TANK TO THE LANDSCAPING PLANTS. COORDINATE TANK INSTALLATION WITH LANDSCAPING CONTRACTORS. PLAN VIEW SECTION VIEW 8' 26' 12" VARIES, SEE PROFILE SECTION LOAD RATES MANHOLE LIDS PER TANK MANUFACTURERS SPECIFICATIONS LOAD RATES MANHOLE LIDS PER TANK MANUFACTURERS SPECIFICATIONS PASEO de PERALTA SIDE 6" 3'-0" RETENTION POND ROCK BERM DETAILS SCALE: N/A REFER TO LANDSCAPE PLAN FOR FINAL SURFACE TREATMENT 2'-6" MAX. 3'-0" 2'-6" BASE WIDTH, TYP. GENERAL NOTE: PLAN & SECTION DETAILS ARE FOR INFORMATION ONLY.THE FINAL ARRANGEMENT OF THE DRYSTACK ROCK BERMS WILL BE BASED UPON FINISH GRADES, RETENTION POND REQUIREMENTS AND LANDSCAPE PLANS, TYP. 6" CURB & GUTTER SCALE: N/A REFER TO SHEET C3 FOR DRIVEWAY PROFILES SURFACE OF PAVING (3) #4 REBAR AS SHOWN ON CHAIRS 3500 PSI CONCRETE, SAW JOINT @ 10' O.C., MAX. & W/ EXPANSION JOINTS @ 25' MAX.SURFACE OF SIDEWALK ngineering & Design Santa Fe, New Mexico 87502e l P.O. Box 5861 (505) 470-2895 www.rebelengineeringnm.com R B E Structural, Civil & Architectural Engineering . Santa Fe New Mexico Site Grading and Drainage C-2 Grading and Drainage Plan Preliminary 507 & 511 Paseo de Peralta TOW 7553.1' TOW 7553.1' PARALLEL CURB RAMP SCALE: N/A DRIVEWAY PROFILE @ TRENCH DRAIN SCALE: 3" = 1'-0" Elevation Elevation Alignment - CL DRIVEWAY 6960 6965 6970 6960 6965 6970 -0+010+00 0+50 0+90 1.69% 1.70% 1.95% 0.84% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 3.06% 0.00% 0.00% 0.00% 0.00% 0.00% EXISTING SURFACE @ ALIGNMENT SIDEWALK ENTRY, MAX. CROSS SLOPE 1.95% TRENCH DRAIN, SEE PLAN VIEW 8000 GALLON CAPACITY CISTERN, BEYOND, CONNECTED TO 507 PdP ROOF DRAINS 3' Ø x 6' DEPTH CMP WET WELL W/ LOWER HALF PORTION FILLED WITH 3 4" ROUNDED GRAVEL, TYP. BOTTOM OF CMP WET WELL TO BE ENCLOSED IN FILTRATION FABRIC 1" LOAD RATED STEEL GRATE IN CONCRETE COLLAR OVER TRENCH DRAINS, SEE PLAN VIEW & DETAIL 3/C2 PROPOSED DRIVEWAY PROFILE @ TRENCH DRAIN, SEE DETAIL 4/C5 Elevation Elevation 6960 6965 6970 6960 6965 6970 -0+010+00 0+50 0+65 DRIVEWAY NORTH CROSS SECTION E-W SCALE: 3" = 1'-0" EXISTING SURFACE @ ALIGNMENT PROPOSED ASPHALT SURFACE @ ALIGNMENT TRENCH DRAIN PARKING AREA PARKING AREA CURB AT ENTRY RAMP, SEE PLAN VIEW CURB AT ENTRY RAMP, SEE PLAN VIEW 0.00% -0.13% 0.10% 2.17% 1.92% 0.76% 0.76% 0.76% 1.00% Elevation Elevation 6960 6965 6970 6960 6965 6970 -0+010+00 0+50 0+65 0.00% -1.06% -1.06% -1.06% -2.00% -1.15% -7.06% -8.41% -8.41% -0.13% 6.22% 6.22% 6.22% 1.49% 1.49% 2.00% 1.51% 1.50% 1.50% 1.50% 0.00% DRIVEWAY SOUTH CROSS SECTION E-W SCALE: 3" = 1'-0" EXISTING SURFACE @ ALIGNMENT PROPOSED ASPHALT SURFACE @ ALIGNMENT TRENCH DRAIN PARKING AREA PARKING AREA PARKING ACCESS AT ENTRY RAMP, SEE PLAN VIEW INTERFACE OF PARKING AREA TO FIN. FLR. OF 507 PdP, SEE PLAN VIEW Elevation Elevation 6960 6965 6970 6960 6965 6970 -0+010+00 0+46 0.00% 0.94% 0.94% -0.78% 0.95% 0.95% 0.95% 5.27% 0.95% 0.95% 0.95% 0.62% 0.95% 0.95% 0.95% -0.00% DRIVEWAY EAST CROSS SECTION N-S SCALE: 3" = 1'-0" EXISTING SURFACE @ ALIGNMENT PROPOSED ASPHALT SURFACE @ ALIGNMENT PARKING AREA INTERFACE OF PARKING AREA TO FIN. FLR. OF 511 PdP, SEE PLAN VIEWINTERFACE OF PARKING AREA TO FIN. FLR. OF 511 PdP, SEE PLAN VIEW Elevation Elevation Alignment - DRIVEWAY SECTION WEST N-S 6960 6965 6960 6965 -0+010+00 0+46 0.00% 0.01% 0.01% 0.01% -1.33% 0.02% 0.02% 0.02% 0.02% 0.02% 0.02% 0.01% 1.24% 0.00% -0.00% -0.00% DRIVEWAY WEST CROSS SECTION N-S SCALE: 3" = 1'-0" EXISTING SURFACE @ ALIGNMENTPROPOSED ASPHALT SURFACE @ ALIGNMENT PARKING AREA INTERFACE OF PARKING AREA TO FIN. FLR. OF 507 PdP, SEE PLAN VIEW INTERFACE OF PARKING AREA TO FIN. FLR. OF 507 PdP, SEE PLAN VIEW Elevation Elevation Alignment - ENTRY SIDEWALK 6960 6965 6960 6965 -0+010+00 0+45 5.95% 5.76% 4.91% -0.00% -0.00% 0.00% 9.24% 8.16% 6.08% 4.02% 3.51% ENTRY SIDEWALK CROSS SECTION E-W SCALE: 2.5" = 1'-0" NOTE: EXISTING DRIVEWAY ENTRY PROFILE IS NOT ALTERED IN THE PROPOSED DESIGN. ONLY REQUIRED CONCRETE REPAIRS WILL BE MADE. EXISTING SURFACE @ ALIGNMENT EXISTING CONCRETE SURFACE @ ALIGNMENT 30" MIN. 6'-0" MAXIMUM WALL HEIGHT NON-RETAINING 20" LAP MIN. 24" MIN. 3" CLR. 8" MIN. STUCCO SYSTEM, SEE ARCH. COLOR AND FINISH TO MATCH RESIDENCE. SLOPE TOP TO DRAIN NOTE: AT 16" x 16" CMU GATE PILASTERS, PROVIDE 3'-0" x 3'-0" x 10" THICK 3000 PSI CONCRETE FOOTING WITH (4) #4's CONT. HORIZONTAL EACH WAY AND #4 DOWELS IN EACH CORNER OF PILASTER TYP. 6' MAX. CMU YARDWALL NON-RETAINING ngineering & Design Santa Fe, New Mexico 87502e l P.O. Box 5861 (505) 470-2895 www.rebelengineeringnm.com R B E Structural, Civil & Architectural Engineering . Santa Fe New Mexico Driveway & Parking Profiles C-3 Grading and Drainage Plan Preliminary 507 & 511 Paseo de Peralta ROOF DOWNSPOUT DETAIL SCALE: N/A (NYLOPLAST BASIN DETAIL SHOWN, EQUIV. ACCEPTABLE) TYP. 6' MAX. CMU YARDWALL @ EXIST. WALL NON-RETAINING DRAINAGE CALCULATIONS SCALE: N/A 507 ROOF = 4423 FT2 507 PAVING = 2078 FT2 511 PAVING = 3507 FT2 511 ROOF = 6945 FT2 511 LANDSC. = 4654 FT2 SITE AREAS EXISTING SITE LOT 507 (ASPHALT) = 8012 FT² EXISTING SITE LOT 511 (DIRT) = 15106 FT² EXISTING SITE TOTALS = 23118 FT² NEW ROOF TOP AREA, LOT 507 = 4423 FT² NEW ROOF TOP AREA, LOT 511 = 6945 FT² NEW ROOF TOP AREAS, TOTAL = 11368 FT² NEW LANDSCAPE AREA, LOT 507 = 1511 FT² NEW LANDSCAPE AREA, LOT 511 = 4654 FT² NEW LANDSCAPE AREA, TOTALS = 6165 FT² NEW HARDSCAPE AREA, LOT 507 = 2078 FT² NEW HARDSCAPE AREA, LOT 511 = 3507 FT² NEW HARDSCAPE AREAS, TOTAL = 5585 FT² SITE TOTALS PROPOSED SITE LOT 507 = 8012 FT² PROPOSED SITE LOT 511 = 15106 FT² TOTAL = 23118 FT² LEGEND - ROOF TOP AREAS - LANDSCAPE AREAS - HARDSCAPE AREAS 507 LANDSC. = 1511 FT2 TOTAL 507 ROOF = 4423 FT2 507 PAVING = 2078 FT2 511 PAVING = 3507 FT2 511 ROOF = 6945 FT2 511 LANDSC. = 4654 FT2 SITE AREAS EXISTING SITE LOT 507 (ASPHALT) = 8012 FT² EXISTING SITE LOT 511 (DIRT) = 15106 FT² EXISTING SITE TOTALS = 23118 FT² NEW ROOF TOP AREA, LOT 507 = 4423 FT² NEW ROOF TOP AREA, LOT 511 = 6945 FT² NEW ROOF TOP AREAS, TOTAL = 11368 FT² NEW LANDSCAPE AREA, LOT 507 = 1511 FT² NEW LANDSCAPE AREA, LOT 511 = 4654 FT² NEW LANDSCAPE AREA, TOTALS = 6165 FT² NEW HARDSCAPE AREA, LOT 507 = 2078 FT² NEW HARDSCAPE AREA, LOT 511 = 3507 FT² NEW HARDSCAPE AREAS, TOTAL = 5585 FT² SITE TOTALS PROPOSED SITE LOT 507 = 8012 FT² PROPOSED SITE LOT 511 = 15106 FT² TOTAL = 23118 FT² LEGEND - ROOF TOP AREAS - LANDSCAPE AREAS - HARDSCAPE AREAS 507 LANDSC. = 1511 FT2 TOTAL Santa Fe ngineering & Design Santa Fe, New Mexico 87502e l P.O. Box 5861 (505) 470-2895 www.rebelengineeringnm.com R B E Structural, Civil & Architectural Engineering . New Mexico Grading and Drainage Calculations & Misc. Details C-4 Grading and Drainage Plan Preliminary 507 & 511 Paseo de Peralta WET WELL SECTION SCALE: N/A 3'Ø CMP WET WELL, FILL 1 3 W/ 1 2" - 3 4" SPLIT FACE GRAVEL 8" DEPTH, NOMINAL CONCRETE COLLAR CAP FOR 3"Ø CMP (3) #4 HOOP BARS, SEE PLAN VIEW #4 BARS @ EDGES OF GRATE OPENING, SEE PLAN VIEW FINISH DRIVEWAY ENTRY PAVING TRENCH DRAIN SYSTEM 1" MIN. CONCRETE EDGE FOR GRATE BEARING, SEE DETAIL 7/C2 3"x3" CIRCULAR NOTCH FOR CMP BEARING 3'-015 16" FLD. VRFY. 1" VEHICULAR LOAD RATED GRATE, TYP. WET WELL CAP - PLAN SCALE: N/A (3) #4 HOOP BARS, SEE SECTION VIEW (4) #4 BARS @ EDGES OF SQUARE GRATE OPENING SEE SECTION VIEW5'Ø CONCRETE CMP COLLAR CAP 32" SQUARE GRATE OPENING FROM L1x1x 3 16" ANGLE, PROVIDE 1" MIN WIDTH FOR GRATE ON CONCRETE LIP CLASS B RATED TRENCH DRAIN GRATES, TYP. Ø5'-0" 32" SQ. OPEN. ABOVE CONC. SHELF 37"± CONCRETE SHELF FOR TOP OF CMP WET WELL 33"Ø HOLE IN CONC. CAP, ACCESS TO WET WELL, SEE SECTION DETAILS, THIS SHEET Ø2'-9"(6) #4 BARS, SEE SECTION VIEW 1" VEHICULAR LOAD RATED GRATE, TYP. WET WELL CAP DETAIL SCALE: N/A 32" SQ. GRATE RESTING ON 1" CONCRETE FORMED SHELF 1" VEHICULAR LOAD RATED GRATE, TYP. (6) #4 STIRRUPS, Ø VARIES, FLD. MEASURE (6) #4 STIRRUPS, Ø VARIES, FLD. MEASURE 2'-6" PASEO ENTRANCE, MATCH EXIST. GRADE 8" MIN. 3'-1"± 4 1 2" ± DRIVEWAY DRAINAGE TRENCH SECTION NOTE: GENERIC TRENCH DRAIN SHOWN. THE CONTRACTOR SHALL PROVIDE TRENCH DRAIN SPECIFICATIONS FROM AN APPROVED VENDOR FOR APPROVAL BY THE OWNER. 15 8" (clear opening for Grating width) (clear opening for Drain width) 13 8" Recommended type of 'L' Trimmer for Grating Seating and to prevent any Point-Breaking. ( JONITE ' L' Trimmer would be an alternative. ) Recommended 2 to 3mm Allowance gap on each side 12" MIN. 8 3 8" MIN. 6 1 2"(min.) 1'-8" 83 8" (2) #5 BARS, CONT. #4 BARS @ 16" O.C., TYP. 6" MIN. TRENCH DRAIN GRATING SHALL BE LOAD RATED FOR VEHICULAR TRAFFIC 1 2" Elevation Elevation Alignment - CL THRU PONDS 6960 6965 6970 6975 6980 6985 6990 6960 6965 6970 6975 6980 6985 6990 -0+010+00 0+50 1+00 1+50 1+62 17.84% 3.22% 3.39% 9.20% 5.12% 0.68% 7.18% -0.87% 0.00% 25.76% 11.06% 8.69% 8.64% 8.64%8.58% -1.99% -1.85% -0.68% 15.44% -20.71%-20.84%0.00% -0.00% 13.96% 14.20% GRADE BREAK STA = 0+00.00 ELEV = 6961.899 GRADE BREAK STA = 1+00.75 ELEV = 6969.060 GRADE BREAK STA = 1+62.47 ELEV = 6969.961 PROPOSED GRADE @ CL 511 NORTH RETENTION PONDS NORTH OVERFLOW & RETENTION POND 1, CAPACITY = 170 FT3 @ 1' DEPTH EXISTING GRADE NORTH OVERFLOW & RETENTION POND 2 CAPACITY = 311 FT3 @ 1' DEPTH. SEE SECTION 5/C5 NORTH EAST RETENTION POND,CAPACITY 976 FT3 @ 1.5' DEPTH SECTION PROFILE THRU 511 NORTH RETENTION PONDS SCALE: 1 : 10 TYPICAL POND SECTION SCALE: N/A PLANTINGS PER LANDSCAPE PLANPLANTINGS PER LANDSCAPE PLAN ROCK BERM, SEE DETAILS SHT. 2/C2 SOIL TREATMENT PER LANDSCAPE PLANS2 SUBGRADE PREPARATION PER GRADING AND DRAINAGE PLAN, SHT. C2 Santa Fe ngineering & Design Santa Fe, New Mexico 87502e l P.O. Box 5861 (505) 470-2895 www.rebelengineeringnm.com R B E Structural, Civil & Architectural Engineering . New Mexico Grading and Drainage Misc. Details C-5 Grading and Drainage Plan Preliminary 507 & 511 Paseo de Peralta