130 GRANT AVENUE, SUITE 101 SANTA FE, NEW MEXICO 87501 PHONE: 505.820.7444 August 10, 2026 Revised October 30, 2026 Lani McCulley, Planner Senior Historic Preservation Division City of Santa Fe 200 Lincoln Avenue Santa Fe, NM 87501 RE: Letter of Application – HDRB Review 135 Grant Avenue (Otero-Bergere House) Portal & Balcony Reconstruction Dear Lani, This letter is submitted on behalf of 123-135 Grant, LLC/Georgia O’Keeffe Museum (“Applicant”) in application for the proposed reconstruction of the porch, balcony, and pergola on the west façade of the O’Keeffe Museum Research Center located at 135 Grant Avenue, for consideration by the Historic Districts Review Board on November 10, 2026. Project Description The Otero-Bergere House, originally constructed in the 1870’s, is located in the Downtown and Eastside Historic District and designated as Significant. In 1926, the style was modified to Pueblo Revival, including the addition of a second story and associated balcony, and reconstruction of the front porch. The porch/balcony elements were maintained, restored, and replaced over the years, as described below: • In 2001, the structure was remodeled and established as the O’Keeffe Museum Research Center. At this time, the porch/balcony was “restored”. • In 2011, the following maintenance and repairs were conducted: ➢ Porch roof repair. ➢ Maintenance, repair, and some replacement of woodwork. ➢ Replacement of rotted fascia board with galvanized metal flashing. ➢ Replacement of drip edge. ➢ Replacement of ornamental carpentry on balcony columns. ➢ Capped purlins with galvanized metal. ➢ Capped second story rafters with galvanized metal. • In 2017, the porch was repaired and rotten wood was replaced in-kind. Letter of Application 135 Grant Avenue Page 2 of 3 130 GRANT AVENUE, SUITE 101 SANTA FE, NEW MEXICO 87501 PHONE: 505.820.7444 FACSIMILE: 505.820.7445 The existing conditions of the porch, balcony, and pergolas were assessed by Eric Trujillo, P.E., a structural engineer with Luchini Trujillo, and his findings are detailed in the attached report. The report indicates that many elements are not original, identifying more contemporary materials and construction methods. Furthermore, the structural elements lack integrity and are no longer sound, creating an unsafe condition, summarized below: • In August 2024, it was discovered that a front porch column was rotting through. This is progressive failure under long-term water exposure, not sudden damage. • Bradbury Stamm Construction conducted an assessment in 2024 and concluded that, in the interest of safety, the balcony requires replacement. • There is evidence of active dry rot and weathering in the 4"×10" members of the upper balcony shade structure/pergola, damaged wood structure and millwork trim throughout, and a header beam plus two 4×10 beams in the lower south shade structure requiring replacement. • The condition is structural, not cosmetic: the footings at the two entry columns have settled and/or deteriorated, causing the structure to move. Replacement footings require engineered design. • The deterioration has progressed from a single column (2024) to the balcony's primary structural members and foundations (2025–26). Piecemeal repair is no longer a viable path. Due to the extent of deterioration and water damage, we propose to reconstruct the porch/balcony elements in-kind as described below: • Replace all materials in-kind, matching material, dimensions, and finish. • Rebuild foundations at columns and perimeter of portal to correct subsidence and protect from future water damage. • Replace composite roof with TPO roof in a tan color. • Address water infiltration through replacement of the gutter system to drain in coordination with new grading to divert water away from the building. • Replace ground floor decking with treated hardwood product for greater longevity. Exception Criteria An exception is requested from SFCC §14-4.6.E.1.I. to permit removal of historic materials. The Exception Criteria are addressed below. a. Do not damage the character of the district; Response: The portal and balcony will be replaced in-kind, thereby preserving the architectural character of the building. Therefore, there will be no impact on the character of the district. b. Are required to prevent a hardship to the applicant or an injury to the public welfare; Letter of Application 135 Grant Avenue Page 3 of 3 130 GRANT AVENUE, SUITE 101 SANTA FE, NEW MEXICO 87501 PHONE: 505.820.7444 FACSIMILE: 505.820.7445 Response: The current conditions of the porch/balcony present a safety hazard, which is a hardship for the applicant and could potentially create an injury to the public. The proposed reconstruction benefits the public welfare by ensuring a safe environment. c. Strengthen the unique heterogeneous character of the City by providing a full range of design options to ensure that residents can continue to reside within the historic districts. Response: Design options considered include repair, restoration, and partial replacement. However, based on the findings of the structural report, the degree of deterioration warrants full reconstruction. This project will have no impact on the ability of residents to reside with the Historic districts. The following documentation is submitted herewith in support of this application: 1. Historic Application 2. Authorization Letter 3. Deed 4. Legal Lot of Record 5. Structural Assessment 6. HDRB Submittal Plans Please let me know if you have any questions or require any additional information. Thank you. Sincerely, Jennifer Jenkins, Principal Luchini Trujillo Structural Engineers, Inc. 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com October 30, 2026 123-135 Grant, LLC c/o Cody Hartley 217 Johnson St Santa Fe, NM 87501 Re: O’Keeffe Research Center Portal 135 Grant Avenue, Santa Fe, NM Dear Cody, We conducted a site visit on October 9, 2026, to evaluate the condition of the west-facing entry portal. This report addresses structural components only. Architectural, mechanical, electrical, or other non-structural elements are excluded. Photo 1: West facing elevation overview General Description The portal is 8’-9” x 46’-6” and a second story pergola with dimensions of 8’-0” x 11’-0”. The framing is a combination of older timber members and newer framing installed alongside or around the original members. In general, much of the exposed framing appears Luchini Trujillo Structural Engineers, Inc. Page 2 O’Keeffe Research Center 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com to have been previously supplemented or replaced, with portions of the original roof joists and column cores remaining. 1. Floor Framing Observations o Floor joists consist of nominal 2x6 members spaced at 16” on-center. o Decking consists of 1x6 tongue and groove boards fastened to the joists with nails. o Floor joists bear directly on concrete in some locations. o The floor slopes away from the building towards the portal entry stairs. Slope appears to have been created by varying the elevation of the floor joists. o Floor framing creates a shallow crawl space enclosed by a concrete curb around the perimeter, which may allow moisture to become trapped beneath the floor. Assessment o The observed 1-1/2” x 5-1/2” joists are consistent with nominal 2x6 S4S lumber which may be indicative of construction date occurring sometime after 1970. o Decking is buckled in several areas, likely resulting from moisture exposure and expansion and contraction of the wood. o The tongue and grooving of the deck plank sides can retain moisture from rain and snow, increasing the potential for deterioration. o Exposed cut ends of the decking revealed decay in several boards. o Crawl space depth varies, and the presence and effectiveness of drainage beneath the floor could not be confirmed. Recommendations o Remove the decking to expose and assess the floor framing. o Replace floor joists exhibiting decay, section loss, or other significant deterioration. o Replace the existing decking with an exterior rated system detailed to drain freely and minimize moisture accumulation. o Verify that positive drainage is provided beneath the floor framing and that water cannot become trapped within the crawl space. Photo 2: Floor joists below decking Photo 3: End view of floor decking Luchini Trujillo Structural Engineers, Inc. Page 3 O’Keeffe Research Center 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com Photo 4: Splitting on floor decking Photo 5: Buckled floor decking Luchini Trujillo Structural Engineers, Inc. Page 4 O’Keeffe Research Center 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com 2. Columns Observations o Structural wood columns are wrapped with ¾” thick slices of wood (veneer). o An opening near mid-height of one column allowed limited observation of the structural column core. Severe decay was observed, with portions of the wood readily breaking away when touched. o Expansion and deterioration of the veneer were most pronounced near the tops and bottoms of the columns. Assessment o The ¾” veneer is non-structural. The concealed column core provides the primary vertical support for the portal. The nominal 1-inch veneer was measured at ¾” thickness which may be S4S lumber, indicative of construction date occurring sometime after 1970. o Severe decay observed near mid-height has reduced the effective cross-sectional area of the column and its ability to resist axial and buckling loads. o Veneer damage is indicative of moisture exposure near the tops and bottoms of the columns. Similar concealed deterioration of the structural column cores may be present at these locations. o Decay at column ends could significantly reduce effective bearing area and compressive capacity. Recommendations o Remove the veneer from the columns to expose and evaluate the structural members. o Replace columns exhibiting decay or measurable section loss. o Provide detailing at the tops and bottoms of replacement columns to prevent water intrusion and prolonged moisture exposure. o Replacement framing members would be specified as solid timber members to match dimensions, profile, and historic appearance. Photo 6: Wood column with veneer Photo 7: Wood column base Luchini Trujillo Structural Engineers, Inc. Page 5 O’Keeffe Research Center 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com Photo 8: Wood condition below veneer Photo 9: Wood column veneer revealed edges Luchini Trujillo Structural Engineers, Inc. Page 6 O’Keeffe Research Center 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com 3. Ceiling and Beams Observations o Structural wood beams are concealed by ¾” veneer. o No accessible opening was available to directly observe the concealed beam framing. o Severe evidence of moisture intrusion was observed immediately adjacent to the beams, including deterioration of portions of the ceiling. o The ceiling finish consists of relatively small panels with numerous installed vents. Assessment o The observed moisture damage adjacent to the concealed beams indicated significant potential for deterioration of the structural framing. o Because the beams were concealed, their structural condition and the extent of any decay or section loss could not be determined during the site visit. Recommendations o Remove the veneer as required to expose and evaluate the structural beams. It is very likely that the beams have lost structural integrity like the columns and will need to be replaced. o Replace beams exhibiting decay or section loss. Replacement framing members would be specified as solid timber members to match dimensions, profile, and historic appearance. o Correct the issue of moisture intrusion before new structural framing or finishes are installed. Photo 10: Ceiling showing vents Photo 11: Edge beam with adjacent moisture damage Luchini Trujillo Structural Engineers, Inc. Page 7 O’Keeffe Research Center 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com 4. Roof Joists and Sheathing Observations o Roof framing consists of nominal 2x8 and 2x4 members spaced at approximately 24” on- center and installed adjacent to older, rough-sawn 2x6 joists. The difference in lumber dimensions and finish suggests that the rough sawn joists are from an earlier period of construction, likely pre-1970, with the newer framing likely installed after 1970. o Ripped plywood strips are installed on top of the 2x8 joists, apparently to create roof slope. o A layer of ¾” plywood sheathing supports the roofing. o Several plywood panel edges do not align with framing members, leaving portions of the panel edges unsupported. o Moisture staining was observed on the exposed framing. Assessment o The newer framing appears to have been installed to supplement the older roof joists. The reason for the previous strengthening could not be confirmed from visual observation alone. o The 2x8 members support the roof sheathing. The 2x4 members appear to support the ceiling panels. o Unsupported plywood panel edges reduce the effectiveness of the sheathing and should be properly supported as part of reconstruction. Recommendations o Remove the roofing and plywood sheathing to expose the roof framing. o Replace framing exhibiting decay, cracking, detrimental notching, or section loss. o Replace or reinstall roof sheathing with all panel edges adequately supported. o Provide new roofing and flashing details that prevent moisture intrusion into structural framing. Photo 12: Overview of balcony roofing Photo 13: Joist framing and plywood edges Luchini Trujillo Structural Engineers, Inc. Page 8 O’Keeffe Research Center 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com 5. Second-Story Pergola Observations o Pergola joists bear on primary support beams and are connected with lag screws or similar mechanical fasteners. o Severe deterioration and section loss were observed in multiple framing members as a result of prolonged moisture exposure. o Sheet metal caps are installed over the tops of wood members. Assessment o Fasteners penetrations through the sheet metal caps may have contributed to moisture intrusion into the wood framing. o The functionality of mechanical connections between the joists, beams, and supporting members are critical to the stability of the pergola. o Severe deterioration at or near these connections has substantially reduced their reliability and creates a potential for connection failure. Recommendations o Replace the pergola joists, beams, columns, and connections. Replacement framing members would be specified as solid timber members to match dimensions, profile, and historic appearance. o Provide new weather protection detailing that prevents water from entering the wood framing. Photo 14: Pergola side overview Photo 15: Pergola joists to beam Luchini Trujillo Structural Engineers, Inc. Page 9 O’Keeffe Research Center 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com 6. First-Story Pergola Observations o Pergola joists bear on primary support beams and are connected with lag screws or similar. o Severe deterioration and section loss were observed in multiple framing members as a result of prolonged moisture exposure. o Sheet metal caps are installed over the tops of wood members. Assessment o Severe deterioration near the mechanical connection has substantially reduced their ability to resist loads. Recommendations o Replace the pergola joists, beams, columns, and connections. Replacement framing members would be specified as solid timber members to match dimensions, profile, and historic appearance. o Provide new weather protection detailing that prevents water from entering the wood framing at fasteners, joints and member ends. Photo 16: Overhead view of pergola Photo 17: Joist to beam connections Luchini Trujillo Structural Engineers, Inc. Page 10 O’Keeffe Research Center 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com 7. Guardrails Observations o Guardrails exist at both ground level and roof level and utilize different configurations. o Ground-level guardrails incorporate diagonal intermediate members. Intersections between the diagonal and vertical members create locations where moisture can accumulate. o Roof-level guardrails utilize vertical intermediate members. o Both guardrail systems rely on posts with fixed bases to provide lateral rigidity. o Several guardrail posts are loose at their bases, allowing significant lateral movement of the guardrail under load. Assessment o Guardrail resistance depends on the rigid attachment of the posts to the supporting structure. o Loose post bases indicate deterioration or failure of the post, connection, supporting material, or a combination thereof. o Moisture accumulation at intersections between diagonal and vertical members has resulted in deterioration that reduces the capacity of the affected connections. Recommendations o Replace deteriorated guardrail posts and post-base connections. Replacement framing members would be specified as solid timber members to match dimensions, profile, and historic appearance. o Due to the extent of observed deterioration and the need to develop adequate structural rigidity, replacement of the existing guardrail assemblies is recommended. o New guardrails and attachments should be designed to resist current code prescribed guardrail loads. Photo 18: Overview of guardrails at level 1 Photo 19: Overview of guardrails at level 2 Luchini Trujillo Structural Engineers, Inc. Page 11 O’Keeffe Research Center 2019 Galisteo St. Ste. D2, Santa Fe, NM 87505 ● 4110 Wolcott Ave. NE Ste. C, Albuquerque, NM 87109 (505) 424-3232 ● info@LTSENG.com ● www.LTSENG.com Summary & Conclusion o Moisture intrusion has resulted in significant deterioration and section loss in multiple structural components of the portal, including joists, beams, columns, guardrails, and connections. The deteriorated framing can no longer safely support imposed loads and is at risk of collapse. The portal should not be used or occupied until repairs are completed. Several additional structural members are concealed by finishes and could not be fully evaluated during our site visits. o The portal is understood to have historical significance, and preservation of structurally sound original members may be possible. Determining which members can be retained will require selective removal of veneer, roofing, stucco, decking, and other finishes to expose the concealed structural framing. Any members that have sustained damage will need to be replaced entirely. o Based on the extent of deterioration observed, access to areas beneath or immediately adjacent to severely deteriorated pergola framing should be restricted until the affected framing has been removed, temporarily supported, or repaired. Closure The conclusions and opinions rendered herein are based on the information and evidence currently available. No warranties, express or implied, are made regarding the accuracy or completeness of these conclusions. Should additional facts or evidence emerge, we reserve the right to review and update opinions accordingly. The recommendations provided are intended as conceptual guidelines for planning and cost estimation purposes only. For precise engineering and design of structural requirements, the services of a licensed professional with expertise in the relevant field should be consulted. Please feel free to contact me if you have any questions or need additional information. Respectfully, Eric D. Trujillo, P.E. O’Keeffe Research Center 135 Grant Avenue Date Issue 9 2 4 - A S h o o f l y S t r e e t , S a n t a F e , N M 8 7 5 0 5 p h ( 5 0 5 ) 2 5 5 - 4 0 3 3 Sheet Title Set Drawn by Checked by Date Consultant File Sheet of 1 3 5 G r a n t A v e n u e , S a n t a F e , N M 8 7 5 0 1 GEORGIA O'KEEFFE MUSEUM Research Center Portal HDRB Review August 10, 2026 HDRB Review NOT FOR CONSTRUCTION 3 135 Grant G100 Cover 260303.vwx H100 Cover Sheet 01 TH CLIENT Georgia O'Keeffe Museum 217 Johnson Street Santa Fe, NM 87501 OWNER'S REPRESENTATIVE / LAND USE JenkinsGavin 130 Grant Avenue, Suite 101 Santa Fe, NM 87501 ph: 505-820-7444 Contact: Jennifer Jenkins email: jennifer@jenkinsgavin.com mobile: 505-930-6149 Contact: Colleen Gavin email: colleen@jenkinsgavin.com mobile: 505-699-0563 ARCHITECTS DNCA, LLC 924-A Shoofly St. Santa Fe, NM 87505 Contact: Devendra N Contractor email: devendra@dncarchitect.com mobile: 505-263-3602 Contact: Deirdre Harris email: dharris@dncarchitect.com mobile: 505-310-2049 PROJECT DIRECTORY Historic Review Submittal Plans August 10, 2026 PASEO DE PERALTA S FEDERAL W MARCY SHERIDAN GRANT W PALACE W SAN FRANCISCO SANDOVAL WATER JOHNSON GUADALUPE Site Location Map Scale: NTS 1 H100 MH 135 GRANT AVE. 123 GRANT AVE 200 W MARCY ST. (Under Construction) AREA OF WORK BOUNDARY Grant Avenue Alley Property Line Property Line Property Line Property Line Sheridan Avenue West Marcy Street Area of Work Scale: NTS 3 H100 ARE OF PROPOSED WORK PROJECT DESCRIPTION The project consists of the entire reconstruction of a wooden porch like-for-like. Differential settlement of columns and any damaged structure will be corrected with rebuilt foundations. Structure, decking, roofing, trim, and railings will be replaced like-for-like. Aerial Image of 135 Grant Avenue. Scale: NTS 2 H100Historic Cultural Properties Inventory (HCPI) Detail Form (FORM 2) Historic Preservation Division, New Mexico Department of Cultural Affairs For HPD Office use only: Please complete HCPI FORM 1 before completing FORM 2 HCPI No.__________ District No.________ ___NRHP ___SRCP Criteria __A __B __C __D 1. Name of property: Otero-Bergere House Fence and Wall 2. Location: 135 Grant Avenue Downtown and Eastside Historic District Santa Fe 3. Local Reference Number: Santa Fe ID: H-2241 4. County: Santa Fe 5. Date of Survey: July 2, 2021; July 7, 2021; July 12, 2021; August 4, 2021; July 25, 2022 18 Figure 11: Otero-Bergere House, 1873. Timothy H. O’Sullivan, photographer. Source: Still Picture Records Section, Special Media Archives Services Division, National Archives and Records Administration, College Park, Maryland. Excerpt from John Murphey Arch. History Svcs Report (APN#10248320) Scale: NTS 4 H100 PROJECT DATA PROJECT NAME: Georgia O’Keeffe Museum, Research Center Portal PROJECT ADDRESS: 135 Grant Avenue Santa Fe, NM 87501 Original Porch Current Existing Porch (Image by DNCA) Scale: NTS 5 H100 Date Issue 9 2 4 - A S h o o f l y S t r e e t , S a n t a F e , N M 8 7 5 0 5 p h ( 5 0 5 ) 2 5 5 - 4 0 3 3 Sheet Title Set Drawn by Checked by Date Consultant File Sheet of 1 3 5 G r a n t A v e n u e , S a n t a F e , N M 8 7 5 0 1 GEORGIA O'KEEFFE MUSEUM Research Center Portal HDRB Review August 10, 2026 HDRB Preliminary Review NOT FOR CONSTRUCTION 2 135 Grant G100 Cover 260303.vwx H101 Existing and Proposed 02 MH Existing Site Plan Scale: 1" = 20'-0" 1 H101 MH Proposed Site Plan Scale: 1" = 20'-0" 3 H101 AREA OF PROPOSED WORK (No change to footprint) Existing West Elevation Scale: 3/16" = 1'-0" 2 H101 4 6 7 1 7 1 3 3 2 8 8 5 5 9 2 Parapet 2nd Level 1st Level Frost Depth Grade Proposed West Elevation Scale: 3/16" = 1'-0" 5 H101 10 10 Parapet 2nd Level 1st Level Frost Depth Grade KEYED NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Existing stucco and windows to remain. Existing door and sidelites to remain. Repair and repaint as required. Existing trim to be evaluated and replaced/repaired as required. Existing foundation subsiding. To be replaced. Existing column subsiding. To be replaced on new foundation. Existing decking and fascia degrading. To be replaced. Existing wood trellis degrading. To be replaced. Existing trim degrading. To be replaced. Existing walkway to remain. Repair as required. All replacements like-for-like. Any damage to existing-to-remain structure or finishes to be repaired. PROJECT NOTES 1. Wood structure, decking, roof, and trim are in a degraded state. Replace all like-for-like, matching material, dimensions, and finish unless noted otherwise. Proposed rebuilt porch and trellis is to visually match the existing. 2. Rebuild foundations at columns and perimeter of porch to correct subsidence and protect from future water damage. 3. Replace composite roof with TPO roof in tan color. 4. Replace gutter system to drain in coordination with updated landscape (under construction). 5. Replace ground floor decking with treated hardwood product for greater longevity. 6. Any damage to existing-to-remain structure or finishes to be repaired. # Date Issue 9 2 4 - A S h o o f l y S t r e e t , S a n t a F e , N M 8 7 5 0 5 p h ( 5 0 5 ) 2 5 5 - 4 0 3 3 Sheet Title Set Drawn by Checked by Date Consultant File Sheet of 1 3 5 G r a n t A v e n u e , S a n t a F e , N M 8 7 5 0 1 GEORGIA O'KEEFFE MUSEUM Research Center Portal HDRB Review August 10, 2026 HDRB Preliminary Review NOT FOR CONSTRUCTION 2 135 Grant G100 Cover 260717.vwx H102 Existing and Proposed Plan 02 PROJECT NOTES 1. Wood structure, decking, roof, and trim are in a degraded state. Replace all like-for-like, matching material, dimensions, and finish unless noted otherwise. Proposed rebuilt porch and trellis is to visually match the existing. 2. Rebuild foundations at columns and perimeter of porch to correct subsidence and protect from future water damage. 3. Replace composite roof with TPO roof in tan color. 4. Replace gutter system to drain in coordination with updated landscape (under construction). 5. Replace ground floor decking with treated hardwood product for greater longevity. 6. Any damage to existing-to-remain structure or finishes to be repaired. Plan - Existing and Proposed (No Changes to Plan) Scale: 1/8" = 1'-0" 1 H102 NO WORK NO WORK NO WORK NO WORK AREA OF PROPOSED WORK AREA OF PROPOSED WORK