1114 Hickox St., Suite A Santa Fe, NM 87505 505.820.1555 20' 66'-0" 5' 4'-13 4" 20' 15' 10' 10' 10' ASPHALT ASPHALT SHADE SAILS PRIVACY FENCE (MIN. 8' TALL) BIKE PRIVACY FENCE (MAX 8' TALL) 15' STAFF ENTRANCE BENCH DRAINAGE POND, SEE CIVIL DRAINAGE POND, SEE CIVIL BIKE 415'-7" FOR REFERENCE ONLY APPROXIMATE EDGE OF EXISTING ROAD 19'-0"23'-0"19'-0" 15' 5' 15' 10' 10' 10' 10' 10' 11'-712"11'-1012" 5' 9' 9'9' 11' 9'5' 10' ASH ASH 25' 8'-6" 11' 2'-53 4"± 5' 8'-6" (4) @ 23' = 92' 5'-1"± FLARE 3'-2" GATE W/ KNOX + KEYPAD CONTROL 10'-412"3'-512" CRUSHER FINES (TYP.) PEDESTRIAN GATE DELIVERY GATE PRIVACY FENCE (MAX 8'-0" TALL) BENCHASPHALT NEW SIDEWALK BOLLARD (TYP FOR 7) 35' 115'-4" 3'-512" PRIVACY FENCE (MAX 8' TALL) ACCESS TO STAFF PARKING (INFORMAL BETWEEN SKATE PARK & COMMUNITY) 4'-53 4" 10'-11" BENCH STRIPING & ADA RAMPS (AS NEEDED) AWNING OPTION AWNING OPTION ASPHALT BENCH DUMPSTER DUMPSTER REAR SETBACK SIDE SETBACK LANDSCAPE LANDSCAPE RIGHT OF WAY + UTILITY EASEMENT FIRE SERVICE LANE SMOKING AREA PARKING (12 SPOTS) COMMUNITY BUILDING COMMUNITY BUILDING COMMUNITY GARDEN S-04 S-20 S-21 S-07 S-08 ADA S-22 S-23 S-11 C-02 C-03 S-31 S-32 S-33S-10 B-05 S-29 S-05 COMMUNITY GARDENPET RUN (FENCED) COMMON AREA (FENCED) LL LL LL LL LL HB HB HB LANDSCAPE VAN S-06 LL LL FIRE SERVICE LANE LL LL BUS DROP & DELIVERIES01 02 03 05 ADA BRENNER WAY S-15S-14 S-16 S-17S-02S-01 LL LL LL LL LL SIDE SETBACK S-28 ADA S-35 S-36 STORAGESTORAGE STORAGE O-04 IT S-25 S-18 S-19 S-09 S-13 SMOKING AREA LL LL LL LL LL LL LL C-01 LL LL B-01 B-02 B-03 ADA L-01 04 O-02 SECURITY O-03 OFFICE S-12 ADA S-26 S-27 S-34 ADA S-30 S-24 S-03 O-01 OFFICE L-02 B-06 ADA B-04 COMMUNITY BUILDING LLLL STORAGE LL LL LL LL FEFE HEADER CURB HEADER CURB HEADER CURB FE 5' 5' 5' LEGEND ADA BATHBATH LAUNDRY COMMUNITY ROOM FE HB LL SEMI-PERMANENT STRUCTURES + PLUMBING PERMANENT STRUCTURES COMMUNITY QTY: 3 QTY: 4 QTY: 2 QTY: 2 FIRE EXTINGUISHER. QTY: 3 HOSE BIBB. QTY: 3 LOW LANDSCAPE LIGHT. QTY: 19 SLEEPER 120 ADA SLEEPER 120 TEMPORARY STRUCTURES OFFICE & STORAGE QTY: 3 QTY: 4 QTY: 1 QTY: 11 QTY: 4 QTY: 21 TEMPORARY STRUCTURES SLEEPING SLEEP 64 IT CRUSHER FINES MILLINGS PLANTING/LANDSCAPE PER LANDSCAPE PLAN ASPHALT PAVEMENT CAST-IN-PLACE CONCRETE CONEX STORAGE COMMUNITY GARDEN PRE-BUILT, ADJUSTABLE ALUMINUM RAMP & LANDING ACCESSIBLE PATH OFFICE/SUPPORT A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. A1 SITE PLAN 1" = 20'-0" PLAN NORTH 0' 10' 20' 40' AS-101 SITE PLAN 25001 AS-101 TD, CB, BJF BJF 10/23/2026 CUA PROGRESS SET LEGEND PROJECT DATA & CODE ANALYSIS CODE REFERENCE 2021 NEW MEXICO COMMERCIAL BUILDING CODE 2018 NEW MEXICO COMMERCIAL ENERGY CONSERVATION CODE 2021 NEW MEXICO PLUMBING CODE 2021 NEW MEXICO MECHANICAL CODE 2020 NEW MEXICO ELECTRICAL CODE 2021 INTERNATIONAL EXISTING BUILDING CODE (2021 IEBC) 2021 INTERNATIONAL BUILDING CODE (2021 IBC) 2021 NFPA 101 LIFE SAFETY CODE (2021 NFPA) 2021 INTERNATIONAL FIRE CODE (2021IFC) 2017 AMERICAN NATIONAL STANDARD ICC A117.1-2017 (ACCESSIBILITY) SANTA FE ZONING R-1 FRONT SETBACK = SIDE SETBACK = 5' REAR SETBACK = 15' SANTA FE PARKING (CHAPTER 14, TABLE 7.4, SECTION 14-7.5) GROUP LIVING, BOARDING, DORMITORY, MONASTERY, OR CONVENT: AS DETERMINED BY THE LAND USE DIRECTOR. · PROVIDED = 15 (12 WITHIN FENCED AREA; INCLUDING 1 VAN ACCESSIBLE) · PROVIDED = 5 (ALONG STREET FRONT; INCLUDING 1 ACCESSIBLE)' · PROVIDED = 10 (INFORMAL AT EAST SIDE OF PROPERTY FOR STAFF) · PROVIDED (1) SHARED LOADING FOR BUS/SERVICE, AND DELIVERIES OCCUPANCY GROUPS · RESIDENTIAL GROUP R-1 (IBC SECTION 310 - BOARDING HOUSES, TRANSIENT WITH MORE THAN 10 OCCUPANTS) · BUSINESS · STORAGE OCCUPANT LOAD (2021 IBC, TABLE 1004.5) OCCUPANT COUNT RESIDENTIAL GROUP R-1 = 4,661 SF / 200 GROSS = 23 OCCUPANTS REALITY ON GROUND: ~ SENIORS: 21 SINGLE PERSON UNITS @ 64 SF NET = 21 ~ ACCESSIBLE: 4 SINGLE-PERSON ADA UNITS @ 120 SF NET = 4 ~ FAMILY: 11 MULTI-PERSON UNITS (UP TO 3 EACH) @ 120 SF NET = 33 TOTAL RESIDENTIAL = 58 BUSINESS = 445 SF / 150 GROSS = 3 REALITY ON GROUND ~ DAYTIME SHIFT & EVENING SHIFT = 10 STORAGE = 640 SF / 500 GROSS = 1 TOTAL OCCUPANTS = 69 PLUMBING COUNT (2021 IBC, TABLE 2902.1) PLUMBING FIXTURES WATER CLOSETS LAVATORIES SHOWERS DF OTHER Male + Female Male + Female RESIDENTIAL 1:10 (M/F) 1:10 (M/F) 1:8 1:100 SERVICE SINK BUSINESS 1: 25 (M/F) 1:40 (M/F) 0 1:100 SERVICE SINK STORAGE 1:100 (M/F) 1:100 (M/F) 0 1:1,000 SERVICE SINK PLUMBING TO BE PROVIDED: WATER CLOSETS = 12 LAVATORIES = 10 SHOWERS = 10 DRINKING FOUNTAIN = 2 SERVICE SINK = 1 KITCHEN SINKS = 2 PROJECT PHASING Occup WATER CLOSETS LAVATORIES SHOWERS GROUP Load M F M F M F M F DF R 58 29 29 2.9 2.9 2.9 2.9 3.625 3.625 1 B 10 5 5 1 1 1 1 0 0 1 S 1 .5 .5 1 1 1 1 0 0 0 TOTAL 69 34.5 34.5 5 5 5 5 4 4 2 REQUIRED PLUMBING PHASE I ALL WORK TO BE COMPLETED IN PHASE I, EXCEPT FOR WORK DESCRIBED AS PHASE II BELOW. PHASE II · ALL LANDSCAPE/PLANTING AND IRRIGATION · ALL CONCRETE CURB & GUTTER IN THE RIGHT OF WAY · CONCRETE SIDEWALK IN THE RIGHT OF WAY Case #2026- 013291EXHIBIT ACONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) 8'-6" HB HB HB FEFE FE 20' VEHICULAR ENTRY GATE W/ KNOX BOX + KEYPAD CONTROL FH FH APPROX. 68' MONUMENT SIGN WITH UNIT IDENTIFICATION MAP APPROX. 165' TO F.H. EXISTING FIRE HYDRANT, ADACENT TO FIRE STATION #7 BRENNER WAY FIRE/EMERGENCY ACCESS LANE 8' TALL FENCE AT SITE PERIMETER GARDEN PET RUN EXIT GATE (AUTOMATED) ENTRY GATES R25' R28' ASH ASH SMOKING AREA COMMUNITY BUILDING COMMUNITY BUILDING COMMUNITY GARDEN S-04 S-20 S-21 S-07 S-08 ADA S-22 S-23 S-11 C-02 C-03 S-31 S-32 S-33S-10 B-05 S-29 S-05 COMMUNITY GARDEN COMMON AREA (FENCED) S-06 S-15S-14 S-16 S-17S-02S-01 S-28 ADA S-35 S-36 STORAGE O-04 IT S-25 S-18 S-19 S-09 S-13 SMOKING AREA B-01 B-02 B-03 ADA L-01 O-02 SECURITY O-03 OFFICE S-12 ADA S-26 S-27 S-34 ADA S-30 S-24 S-03 O-01 OFFICE L-02 B-06 ADA B-04 HEADER CURB C-01 COMMUNITY BUILDING 20' WIDE FIRE/EMERGENCY ACCESS LANE - 75,000 Lbs BEARING CAPACITY, MINIMUM FE FIRE EXTINGUISHER EXISTING FIRE HYDRANT A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. A1 FIRE/EMERGENCY ACCESS PLAN 1" = 20'-0" PLAN NORTH 0' 10' 20' 40' AS-102 FIRE/EMERGENCY ACCESS PLAN 25001 AS-102 TD, BJF BJF 10/23/2026 CUA PROGRESS SET LEGEND NOTES 1. IN ADDITION TO THE FIRE EXTINGUISHER LOCATIONS SHOWN, EACH UNIT/BUILDING IS EQUIPPED WITH A FIRE EXTINGUISHER 2. MINIMUM SEPARATION DISTANCE PROVIDED BETWEEN UNITS IS 10'-0" Case #2026- 013291Length: 416 Feet Length: 207.9 Feet Length: 723.4 Feet 2395 Richards Ave. Santa Fe County Parcels Water Pipe Distribution Fire Hydrants Parcels City Limits 8/20/2025, 2:56:15 PM 0 0.02 0.040.01 mi 0 0.03 0.060.01 km 1:1,128 City of Santa Fe, Bureau of Land Management, Texas Parks & Wildlife, Esri, HERE, Garmin, USGS, NGA, EPA, USDA, NPS |FIRE HYDRANT DISTANCECONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) DUMPSTER DUMPSTER SMOKING AREA COMMUNITY BUILDING COMMUNITY BUILDING COMMUNITY GARDEN ADA COMMUNITY GARDENPET RUN (FENCED) PLAY AREA (FENCED) HB HB HB VAN BUS DROP & DELIVERIES ADA BRENNER WAY (EXISTING ASPHALT) STORAGE STORAGE O-04 IT SMOKING AREA ADA SECURITY O-03 OFFICE ADA OFFICE COMMUNITY BUILDING STORAGE STORAGE PROGRESS SET - FOR COMMENT FOR REVIEW ONLY NOT FOR CONSTRUCTION ATENCIO ENGINEERING, INC. CONSULTING CIVIL ENGINEERS CONSULTANTS Date Issue Set Drawn by Checked by Date PRELIMINARY Plot Date 09/30/2026 PLB AMA 2395 Richards Ave, Santa Fe, NM 87507 CITY OF SANTA FE MICRO-COMMUNITY C-3002026- 013291CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) DUMPSTER DUMPSTER SMOKING AREA COMMUNITY BUILDING COMMUNITY BUILDING COMMUNITY GARDEN ADA COMMUNITY GARDENPET RUN (FENCED) PLAY AREA (FENCED) HB HB HB VAN BUS DROP & DELIVERIES ADA BRENNER WAY (EXISTING ASPHALT) STORAGE STORAGE O-04 IT SMOKING AREA ADA SECURITY O-03 OFFICE ADA OFFICE STORAGE STORAGE C-400 PROGRESS SET - FOR COMMENT FOR REVIEW ONLY NOT FOR CONSTRUCTION ATENCIO ENGINEERING, INC. CONSULTING CIVIL ENGINEERS CONSULTANTS Date Issue Set Drawn by Checked by Date PRELIMINARY Plot Date 09/30/2026 PLB AMA 2395 Richards Ave, Santa Fe, NM 87507 CITY OF SANTA FE MICRO-COMMUNITY2026- 013291CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) DUMPSTER DUMPSTER SMOKING AREA COMMUNITY BUILDING COMMUNITY BUILDING COMMUNITY GARDEN ADA COMMUNITY GARDENPET RUN (FENCED) PLAY AREA (FENCED) HB HB HB VAN BUS DROP & DELIVERIES ADA BRENNER WAY (EXISTING ASPHALT) STORAGE STORAGE O-04 IT SMOKING AREA ADA SECURITY O-03 OFFICE ADA OFFICE STORAGE STORAGE C-401 PROGRESS SET - FOR COMMENT FOR REVIEW ONLY NOT FOR CONSTRUCTION ATENCIO ENGINEERING, INC. CONSULTING CIVIL ENGINEERS CONSULTANTS Date Issue Set Drawn by Checked by Date PRELIMINARY Plot Date 09/30/2026 PLB AMA 2395 Richards Ave, Santa Fe, NM 87507 CITY OF SANTA FE MICRO-COMMUNITY2026- 013291CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) DUMPSTER DUMPSTER FIRE SERVICE LANE SMOKING AREA PARKING (12 SPOTS) COMMUNITY BUILDING COMMUNITY BUILDING COMMUNITY GARDEN S-04 S-20 S-21 S-07 S-08 ADA S-22 S-23 S-11 C-02 C-03 S-31 S-32 S-33S-10 B-05 S-29 S-05 COMMUNITY GARDENPET RUN (FENCED) PLAY AREA (FENCED) LL LL LL LL LL LL FE HB HB HB VAN FE FE S-06 LL LL FIRE SERVICE LANE LL LL BUS DROP & DELIVERIES01 02 03 05 ADA S-15S-14 S-16 S-17S-02S-01 LL LL LL LL LL LL LL S-28 ADA S-35 S-36 STORAGE STORAGE STORAGE STORAGE O-04 IT S-25 S-18 S-19 S-09 S-13 SMOKING AREA LL LL LL LL LL LL LL C-01 LL LL B-01 B-02 B-03 ADA L-01 04 O-02 SECURITY O-03 OFFICE S-12 ADA S-26 S-27 S-34 ADA S-30 S-24 S-03 O-01 OFFICE L-02 B-06 ADA B-04 COMMUNITY BUILDING LL LL LL SYMBOL CODE DESCRIPTION QTY LP100 OVERALL PLANTING PLAN A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 25001 LI, GM MS LP1002026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING E-001 LEGEND & GENERAL NOTES ELECTRICAL 25001 JT 25104_E-001 10/21/2026 10:17:59 AM ELECTRICAL GENERAL NOTES A. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2020 NATIONAL ELECTRICAL CODE (NEC) AND REGULATIONS OF STATE AND LOCAL AUTHORITIES HAVING JURISDICTION (AHJ) IN A NEAT AND WORKMANLIKE MANNER. B. CONTRACTOR SHALL COORDINATE WITH SERVING UTILITY COMPANY NEW SERVICE DEPARTMENT AND OBTAIN A PROJECT SPECIFIC "STANDARDS LETTER" PRIOR TO BIDDING, ORDERING, OR COMMENCING WITH THE ELECTRICAL DISTRIBUTION PORTION OF THIS PROJECT. C. ALL REQUIREMENTS OF THE SERVING UTILITY COMPANY FOR ELECTRICAL SERVICE SHALL BE INCLUDED IN THE CONTRACTOR'S BID. D. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANIES PROVIDING TELEPHONE, CATV, AND INTERNET IN ORDER TO ASCERTAIN JOB SPECIFIC UTILITY REQUIREMENTS AND COMPLIANCE WITH THOSE REQUIREMENTS SHALL BE INCLUDED IN THE CONTRACTOR'S BID TO ENSURE SERVICE TO EACH DEMARCATION. E. BY SUBMITTING A BID, THE CONTRACTOR AFFIRMS THEY HAVE FAMILIARIZED THEMSELVES WITH THE PROJECT SITE, PLANS, SPECIFICATIONS AND ALL APPLICABLE CODES IN ORDER TO PROVIDE A COMPREHENSIVE AND COMPLETE BID. OFF HOUR(S) AND/OR PREMIUM TIME MAY BE REQUIRED TO FACILITATE PORTIONS OF THE WORK, AND SHALL BE INCLUDED IN THE CONTRACTOR'S BID. F. ALL DEVICES SHALL BE WHITE WITH STAINLESS STEEL PLATES, INSTALLED FOR ADA COMPLIANCE UNLESS NOTED OTHERWISE. RECEPTACLES SHALL ALL BE RATED FOR THEIR INTENDED USE AND TAMPER RESISTANT AS REQUIRED BY NEC 406. G. ALL TELEPHONE, DATA, SECURITY, CATV, SOUND AND INTERCOM LOW VOLTAGE SYSTEMS ARE PROVIDED BY OTHERS UNLESS NOTED OTHERWISE. NOTE: * LOW VOLTAGE CONTRACTORS ARE REQUIRED TO OBTAIN INDEPENDENT PERMITS FROM THE AHJ PRIOR TO STARTING THEIR WORK. H. UTILIZE "DEEP" 4-SQUARES WHERE REQUIRED TO COMPLY WITH NEC 314.16 EXTRA CONSIDERATION SHALL BE GIVEN TO BOXES SUPPLYING HOME-RUNS. I. CONFIRM EXACT ROUGH-IN DIMENSIONS WITH ARCHITECTURAL DRAWINGS, AND APPLICABLE KITCHEN/APPLIANCE EQUIPMENT, AND FURNITURE/MILL-WORK PLAN(S). EXTRA CARE SHALL BE EXERCISED IN COORDINATING THE EXACT REQUIREMENT(S) OF SPECIALTY EQUIPMENT INCLUDING, BUT NOT LIMITED TO, MECHANICAL EQUIPMENT, PLUMBING EQUIPMENT, MEDICAL EQUIPMENT, OR PROCESSING EQUIPMENT. ALL PENETRATIONS IN FIRE RATED WALLS, PARTITIONS, FLOORS, OR CEILINGS SHALL BE SEALED WITH FIRE STOPPING MATERIAL OR OTHER APPROVED METHOD(S) TO MAINTAIN THE FIRE RATED ASSEMBLY PER NEC 300.21. REFER TO ARCHITECTURAL DRAWINGS FOR THE LOCATIONS OF WALL AND FLOOR ASSEMBLIES. ELECTRICAL DEVICES INSTALLATION SHALL COMPLY WITH ACCESSIBILITY (ADA) STATUTE ICC/ANSI 117.1 SECTION 308. SPECIFICALLY: MOUNT APPLICABLE SWITCHES, RECEPTACLES, AND ENVIRONMENTAL CONTROLS SO THAT THEY ARE LOCATED WITH THE TOP OF THE DEVICE NO HIGHER THAN 48" ABOVE FINISHED FLOOR (AFF) AND THE BOTTOM OF THE DEVICE NO LOWER THAN 15" AFF. J. CONTRACTOR TO SAW-CUT / REMOVE / PATCH EXISTING ARCHITECTURAL SURFACES INCLUDING BUT NOT LIMITED TO SLABS, WALLS AND ROOFS. WHENEVER BUILDING ENVELOPE OR ROOF PENETRATIONS ARE REQUIRED, OR ABANDONED, IN THE EXECUTION OF THE WORK, CONTRACTOR SHALL SEAL PENETRATIONS AS REQUIRED TO MAINTAIN APPLICABLE WARRANTIES OR AS REQUIRED BY MATERIAL(S) MANUFACTURER'S REQUIREMENTS. K. SHARED NEUTRALS ARE NOT PERMISSIBLE UNLESS NOTED OTHERWISE. L. CONDUCTOR TICK MARKS, WHERE SHOWN, ARE SHOWN FOR CONVENIENCE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL CONDUCTORS WHETHER SHOWN OR NOT INCLUDING "TRAVELERS" AND DIMMING CONDUCTORS AS NECESSARY FOR COMPLETELY OPERATIONAL SYSTEMS. M. BRANCH CIRCUITING SHALL BE COPPER WIRE IN CONDUIT UNLESS SPECIFICALLY NOTED OTHERWISE. MINIMUM WIRE SIZE IS #12 AWG. WHEN CONDUIT IS UTILIZED, ALL FITTINGS SHALL BE COMPRESSION TYPE AND COLOR CODING VINYL BANDS IDENTIFYING DIFFERENT SYSTEMS SHALL BE AFFIXED AT EACH BOX, PANELBOARD, AND EVERY ACCESSIBLE 10'-0" N. THE ELECTRICAL CONTRACTOR SHALL INSTALL ALL CONDUIT REQUIRED FOR MECHANICAL SYSTEMS CONTROLS. ALL CONTROLS WIRING SHALL BE INSTALLED AND TERMINATED BY CONTROLS CONTRACTOR. COORDINATE LOCATION AND ROUTING OF CONTROLS CONDUIT WITH MECHANICAL PLANS AND WITH MECHANICAL SEQUENCE OF CONTROLS. O. ALL PANELS AND DISTRIBUTION BOARDS, NEW/EXISTING SHALL HAVE TYPEWRITTEN DIRECTORIES AND EQUIPMENT I.D. NAMEPLATES UPON COMPLETION OF ANY ELECTRICAL MODIFICATIONS UNDER THIS CONTRACT. P. CONTRACTOR SHALL CONSIDER AND MAKE ADJUSTMENTS IN CONDUIT/WIRE SIZE(S) TO ACCOUNT FOR VOLTAGE DROP PRIOR TO COMMENCING WITH WORK UNDER THIS CONTRACT. VOLTAGE DROP SHALL NOT EXCEED THE FOLLOWING: FEEDERS = 2% BRANCH WIRING = 3% Q. CONTRACTOR SHALL COMPLY WITH NEC 110.16. AFFIX PERMANENT ARC-FLASH HAZARD WARNING LABEL(S) ON ALL APPLICABLE ELECTRICAL EQUIPMENT MODIFIED OR INSTALLED UNDER THIS CONTRACT. R. FOR ELECTRICAL DISTRIBUTION SYSTEMS HAVING A MAIN DISCONNECT RATING OF 1,000-AMPS OR MORE, CONTRACTOR SHALL OBTAIN THIRD PARTY OVER-CURRENT PROTECTION STUDY. ALL OVER-CURRENT DEVICES SHALL BE "SET" OR ADJUSTED TO COMPLY WITH COORDINATION STUDY PRIOR TO FINAL COMMISSIONING. A FULL COPY OF THE COMPLETED STUDY ALONG WITH CONTRACTOR'S CERTIFICATION OF COMPLIANCE SHALL BE INCLUDED IN THE PROJECT'S "CLOSE-OUT" DOCUMENTATION. S. ALL EQUIPMENT AND WORKMANSHIP FURNISHED UNDER THIS CONTRACT SHALL BE WARRANTABLE TO BE FREE FROM ANY DEFECT FOR A PERIOD EQUAL TO 1-YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER. THE ELECTRICAL DESIGN ILLUSTRATED BY THESE PLANS AND SPECIFICATIONS IS IN COMPLIANCE WITH THE 2021 INTERNATIONAL ENERGY CONSERVATION CODE SECTION(S) C405, C408, C501-5, CB103.3, CB103.8, R402.4.5, R402.4.6, R404, R501-5, AND R502, AS SPECIFICALLY APPLICABLE TO THIS PROJECT AS FOLLOWS: 1. C405.2 - LIGHTING CONTROLS (MANDATORY) A. REFER TO LIGHTING PLAN(S) AND/OR DETAIL(S) FOR PROJECT REQUIREMENTS. 2. C405.3 - INTERIOR LIGHTING POWER REQUIREMENTS A. TABLE C405.3.2(1) ALLOWABLE INTERIOR POWER FOR THIS PROJECT IS: ACTUAL INTERIOR POWER IS: 3. C405.4 - EXTERIOR LIGHTING POWER REQUIREMENTS (MANDATORY) A. TABLE C405.5.2(1) - THIS PROJECT IS IN LIGHTING ZONE # 2. B. TABLE 405.5.2(2) - BASE SITE ALLOWANCE: 400W - PARKING AREAS AND DRIVES: 0.04 W/FT2 - WALKWAYS/RAMPS < 10'-0" WIDE: 0.5W/LINEAR FT - WALKWAYS/RAMPS > 10'-0" WIDE, PLAZA AREAS, SPECIAL FEATURE AREAS: 1.10 W/FT2 - PEDESTRIAN AND VEHICULAR ENTRANCES AND EXITS: 14W/LINEAR FT - ENTRY CANOPIES: 0.25W/FT2 C. TABLE 405.5.2(3) - BUILDING FACADES: 0.075W/FT OF GROSS ABOVE-GRADE WALL AREA ACTUAL EXTERIOR POWER IS: 4. C405.6 - ELECTRICAL TRANSFORMER (MANDATORY) A. LOW VOLTAGE DRY-TYPE DISTRIBUTION ELECTRICAL TRANSFORMERS SHALL MEET THE MINIMUM EFFICIENCY REQUIREMENTS AS TESTED AND RATED IN ACCORDANCE WITH DOE 10 CFR 431. B. C405.7 - REFER TO SINGLE LINE DIAGRAM ON SHEET E-600 FOR TRANSFORMER(S) APPLICABLE TO THIS PROJECT. 5. C405.10 - VOLTAGE DROP IN FEEDERS AND BRANCH CIRCUITS A. REFER TO GENERAL NOTE "P" FOR PROJECT VOLTAGE DROP LIMITATIONS. 6. C405.11 - AUTOMATIC RECEPTACLE CONTROL (MANDATORY) A. REFER TO POWER PLAN(S) AND/OR DETAILS FOR PROJECT REQUIREMENTS. 7. C405.12 - ENERGY MONITORING (MANDATORY > 25,000FT2) A. REFER TO SINGLE LINE DIAGRAM ON SHEET E-600 FOR METERING, DATA ACQUISITION SYSTEM, AND GRAPHICAL REPORTING REQUIREMENT(S) APPLICABLE TO THIS PROJECT. 8. C405.13 - ELECTRIC VEHICLE POWER TRANSFER INFRASTRUCTURE. A. TABLE C405.31.1 - REQUIRED EV POWER TRANSFER INFRASTRUCTURE. - REFER TO ELECTRICAL SINGLE LINE DIAGRAM ON SHEET E-600 FOR EVE AND EV CAPABLE REQUIREMENTS APPLICABLE TO THIS PROJECT. 9. C408.3 - FUNCTIONAL TESTING AND DOCUMENTATION OF LIGHTING CONTROLS. A. THE CONTRACTOR OR FACTORY AUTHORIZED COMMISSIONING AGENT SHALL DELIVER TO THE ENGINEER OF RECORD EVIDENCE OF THE LIGHTING CONTROLS HAVING BEEN TESTED AND PERFORMING PROPERLY PRIOR TO OBTAINING FINAL INSPECTION FROM THE AHJ. B. THE CONTRACTOR SHALL DELIVER TO THE OWNER, WITH A COMPLETE COPY DELIVERED TO THE ENGINEER OF RECORD, AS PART OF ITS CLOSE-OUT PACKAGE FULLY DETAILED, LEGIBLE, AS-BUILT DRAWINGS AND THE FOLLOWING IN SATISFACTION OF THE ARTICLE(S) REFERENCED HEREIN: - C408:3.2.1 - LIGHTING CONTROL DRAWINGS. - C408.3.2.2 - LIGHTING CONTROL MANUALS. - C408.3.2.3 - LIGHTING CONTROL REPORT. IECC ELECTRICAL & LIGHTING COMPLIANCE C 60/3/45 60/3/45 60/3 PTZ OC T T D K WR 4 EM T OS WAP M B 2 J J C C S M I CS T VT S CR J L PIV 3OC F FACP FARA S 3 a T C S S S S S S S S S S S OCD S OCF S GENERALLIGHTING FIRE ALARM SPECIAL SYSTEMS POWER HDMI SYMBOL DESCRIPTION SYMBOL DESCRIPTION ELECTRICAL SYMBOL LEGEND (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) AFF AC GFCI E.GR. WR E UG E OH (E) AHJ CONDUCTOR TICK MARKS: NEUTRAL, PHASE, SWITCHED, AND GROUND CONDUCTORS RESPECTIVELY. CROSSHATCHING DEPICTS ITEMS TO BE REMOVED (LIGHT FIXTURES, SWITCHES, RECEPTACLES, CONDUIT AND WIRING, ETC.) HOME-RUN CONDUIT. CAPPED CONDUIT / CONDUIT STUB-OUT. CONDUIT SEAL. ELECTRICAL KEYED NOTE TAG. KITCHEN ITEM TAG, SEE KITCHEN EQUIPMENT ELECTRICAL CONNECTION SCHEDULE. MECHANICAL UNIT TAG (EXAMPLE: BOILER B-2 INDICATED), SEE MECHANICAL EQUIPMENT SCHEDULE. EXISTING. OVERHEAD PRIMARY ELECTRICAL LINE. PRIMARY ELECTRICAL UNDERGROUND FEEDER. EQUIPMENT GROUND. ABOVE FINISH FLOOR. ABOVE COUNTER. WEATHER-RESISTANT. GROUND FAULT CIRCUIT INTERRUPTER. AUTHORITY HAVING JURISDICTION. SINGLE-POLE WALL SWITCH. SUBSCRIPT DESIGNATES CONTROL OF PARTICULAR LIGHTING FIXTURES. THREE-WAY AND FOUR-WAY SWITCHES, RESPECTIVELY. WEATHER-RESISTANT SWITCH. KEY-OPERATED SWITCH. DIMMER SWITCH, 1200W MINIMUM WATTAGE. MECHANICALLY WOUND TWIST-TIMER SWITCH OR ELECTRONIC TIME SWITCH. THERMAL SWITCH. OCCUPANCY SENSOR SWITCH. DUAL-TECHNOLOGY OCCUPANCY DIMMER SWITCH. DUAL-TECHNOLOGY OCCUPANCY SENSOR WITH FAN DELAY CONTROL. 3-WAY / MULTI-WAY OCCUPANCY SENSOR SWITCH. LIGHTING CONTROL OCCUPANCY SENSOR, CEILING MOUNTED. 2'X4' LAY-IN LIGHTING FIXTURE (TROFFER), TYPE INDICATED BY LETTER (TYPICAL). "EM" INDICATES LIGHTING FIXTURE IS SUPPLIED WITH AN EMERGENCY BATTERY PACK. 1'X4' SURFACE MOUNTED LIGHTING FIXTURE. 1'X4' RECESSED (FLANGED) MOUNTED LIGHTING FIXTURE. 2'X2' LAY-IN LIGHTING FIXTURE (TROFFER). UTILITY STRIP FIXTURE. LINEAR PENDANT MOUNTED LIGHTING FIXTURE, LENGTH AS INDICATED. 4' WALL BRACKET MOUNTED LIGHTING FIXTURE. WALL BRACKET LIGHTING FIXTURE. POLE MOUNTED AREA LIGHTING FIXTURE, SINGLE-HEAD. POLE MOUNTED AREA LIGHTING FIXTURE, DOUBLE-HEAD. RECESSED DOWNLIGHT FIXTURE. SURFACE MOUNTED DRUM TYPE LIGHTING FIXTURE. BOLLARD LIGHTING FIXTURE. HIGH-BAY LIGHTING FIXTURE. LOW-BAY LIGHTING FIXTURE. FLUSH IN-GROUND LIGHTING FIXTURE. WALL SCONCE LIGHTING FIXTURE. STEP LIGHT LIGHTING FIXTURE. PENDANT HUNG DECORATIVE LIGHTING FIXTURE. GOOSENECK MOUNTED LIGHTING FIXTURE. TRACK MOUNTED LIGHTING ASSEMBLY, ONE FIXTURE HEAD INDICATED. TWIN-EYE EMERGENCY LIGHTING UNIT WITH BATTERY BACK-UP. TYPE "EM", REFER TO LUMINAIRE SCHEDULE. EXTERIOR EMERGENCY LIGHTING UNIT WITH BATTERY BACK-UP. TYPE "WEM", REFER TO LUMINAIRE SCHEDULE. EXIT SIGN, SINGLE FACE INDICATED BY SHADED QUADRANT. TYPE "EX", REFER TO LUMINAIRE SCHEDULE. EXIT SIGN, DOUBLE-FACED, DIRECTIONAL ARROWS INDICATED. COMBO EXIT SIGN/EMERGENCY TWIN-EYE UNIT TYPE "XEM", REFER TO LUMINAIRE SCHEDULE. PADDLE FAN, WITH OR WITHOUT LIGHT PER LUMINAIRE SCHEDULE. J-BOX WITH FLEXIBLE CONDUIT CONNECTION TO LAY-IN LIGHTING FIXTURES. PHOTOCELL. DAYLIGHT HARVESTING PHOTOSENSOR, CEILING MOUNTED. FIRE ALARM REMOTE ANNUNCIATOR (FARA). FIRE ALARM CONTROL PANEL (FACP). FIRE ALARM MANUAL PULL STATION. CEILING MOUNTED FIRE ALARM AUDIO/STROBE UNIT. FIRE ALARM SMOKE DETECTOR. FIRE PROTECTION SPRINKLER SYSTEM POST INDICATOR VALVE. FIRE ALARM AUDIO/STROBE UNIT. FIRE ALARM STROBE UNIT. FIRE ALARM DUCT SMOKE DETECTOR. SECURITY/INTRUSION ALARM SYSTEM DOOR SWITCH. MOTION SENSOR FOR SECURITY/INTRUSION ALARM SYSTEM. MODULAR FURNITURE POWER CONNECTION POINT. DOOR OPERATOR PUSH-PAD UNIT (ADA COMPLIANT). WIRELESS ACCESS POINT. MAGNETIC DOOR LOCK. DOORBELL/CHIME. DOORBELL SYSTEM PUSHBUTTON. INTERCOM HEAD-END UNIT. DOOR ACCESS CARD READER. PROJECTOR. EMERGENCY PUSH BUTTON. SURVEILLANCE CAMERA. PTZ = PAN, TILT, ZOOM. WEATHER-RESISTANT IF LOCATED ON BUILDING EXTERIOR. CATV OUTLET FLUSH FLOOR VOICE/DATA OUTLET. FLUSH CEILING VOICE/DATA OUTLET. COMBINATION VOICE/DATA OUTLET, UP 18" U.N.O. THERMOSTAT CALL-IN SWITCH (PUSH-TO-CALL) FOR INTERCOM SYSTEM. MICROPHONE OUTLET. SURFACE MOUNTED SOUND SYSTEM SPEAKER. SPEAKER, CEILING MOUNTED COMBINATION CLOCK/SPEAKER UNIT. CLOCK. MOTOR, HP SIZE AS INDICATED, "F" = FRACTIONAL HORSEPOWER. COMBINATION MOTOR STARTER/FUSED DISCONNECT SWITCH, NEMA 3R IF OUTSIDE. MOTOR STARTER. FUSED DISCONNECT SWITCH, NEMA 3R IF OUTSIDE, AMPS/ POLES / FUSE SIZE INDICATED. NON-FUSED DISCONNECT SWITCH, NEMA 3R IF OUTSIDE, AMPS / POLES INDICATED. DRY-TYPE, STEP-DOWN / STEP-UP TRANSFORMER. DISTRIBUTION POWER PANEL, REFER TO ASSOCIATED PANEL SCHEDULE. FLUSH MOUNTED PANELBOARD, REFER TO ASSOCIATED PANEL SCHEDULE. SURFACE MOUNTED PANELBOARD, REFER TO ASSOCIATED PANEL SCHEDULE. MULTI-RECEPTACLE RACEWAY (PLUGMOLD). CABLE TRAY. GANGABLE 3-COMPARTMENT MEDIA CENTER. DUPLEX RECEPTACLE WITH BUILT-IN USB CHARGER OUTLET. ISOLATED GROUND DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE. SPECIAL RECEPTACLE, TYPE AS NOTED. CEILING MOUNTED DUPLEX RECEPTACLE. SPLIT-WIRED DUPLEX RECEPTACLE GROUND FAULT CIRCUIT INTERRUPTER (GFCI) DUPLEX RECEPTACLE WITH WEATHER-RESISTANT (WR) COVER. QUADPLEX RECEPTACLE, 18" AFF TO CENTER. GFCI PROTECTED DUPLEX RECEPTACLE. RECEPTACLES WITH TRIP RESET SHALL BE IN READILY ACCESSIBLE LOCATION. DUPLEX RECEPTACLE, 18"AFF U.N.O. (#) INDICATES CIRCUIT. WALL JUNCTION BOX. CEILING JUNCTION BOX. # RELAY INTERFACE TAMPER RESISTANT RECEPTACLE. PC OR OR EC F S S EVAPORATIVE COOLER SWITCH. PADDLE FAN / LIGHT CONTROL SWITCHES. SWITCHES ALLOW INDEPENDENT CONTROL OF FAN SPEED AND LIGHTING. P S PILOT SWITCH. UNO UNLESS NOTED OTHERWISE. CARBON MONOXIDE DETECTOR.CO O.F.C.I. OWNER FURNISHED, CONTRACTOR INSTALLED. 1 1. E-001 ELECTRICAL LEGEND, GEN NOTES, FIXTURE SCHEDULE, IECC CALCS 2. ES101 ELECTRICAL SITE PLAN 3. E-401 ELECTRICAL ENLARGED PLANS 4. E-402 ELECTRICAL ENLARGED PLANS 5. E-403 ELECTRICAL ENLARGED PLANS 6. E-501 ELECTRICAL DETAILS 7. E-601 RISER DIAGRAM, SERVICE CALCS 8. E-602 PANEL SCHEDULES ELECTRICAL SHEET INDEX2026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) RIGHT OF WAY + UTILITY EASEMENT P1 P1 P1 P1 P1 P1 EV "SE SITE" DUMPSTER DUMPSTER COMMUNITY BUILDING COMMUNITY BUILDING S-04 S-20 S-21 S-07 S-08 ADA S-22 S-23 S-11 C-02 C-03 S-31 S-32 S-33S-10 S-29 S-05 S-06 S-15S-14 S-16 S-17S-02S-01 S-28 ADA S-35 S-36 STORAGE STORAGE STORAGE O-04 IT S-25 S-18 S-19 S-09 S-13 C-01 B-01 B-02 B-03 ADA L-01 O-02 SECURITY O-03 OFFICE S-12 ADA S-26 S-27 S-34 ADA S-30 S-24 S-03 O-01 OFFICE COMMUNITY BUILDING B-05 L-02 B-06 ADA B-04 LL LL LL LL LL LL LL LL LLLL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL P1 P1 P2 P2 "DP1" PANEL "CO2" PANEL "SLEEP 2" PANEL "DP2" PANEL "CO3" PANEL "SLEEP3" PANEL "SEC" PANEL CR CR "SE SITE" PANEL LOOP DETECTION GATE OPENER 2PMT 1 3 LOOP DETECTION SEC 13 GATE OPENER W W WEM WEM W WEM WEM W W CR WEM W WEM W W W 6 TYP 6 TYP 6 TYP 6 TYP 6 TYP 6 TYP A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING A1 SITE PLAN - ELECTRICAL 1" = 20'-0" PLAN NORTH 0' 10' 20' 40' ES-101 SITE PLAN ELECTRICAL 25001 JT 25104_ES-101 10/21/2026 10:18:41 AM IF ANY UTILITY LINES, PIPELINES, OR UNDERGROUND UTILITY LINES ARE SHOWN ON THESE DRAWINGS, THEY ARE SHOWN IN APPROXIMATE MANNER ONLY, AND SUCH LINES MAY EXIST WHERE NONE ARE SHOWN. IF ANY SUCH EXISTING LINES ARE SHOWN, THE LOCATION IS BASED UPON INFORMATION PROVIDED BY THE UTILITY OR PIPELINE COMPANY, THE OWNER OR BY OTHERS, AND THE INFORMATION MAY BE INCOMPLETE, OR MAY BE OBSOLETE BY THE TIME CONSTRUCTION COMMENCES. THE ENGINEER HAS UNDERTAKEN NO FIELD VERIFICATION OF THE LOCATION, DEPTH, SIZE OR TYPE OF EXISTING UTILITY LINES, PIPELINES, OR UNDERGROUND UTILITY LINES, MAKES NO REPRESENTATION PERTAINING THERETO, AND ASSUMES NO RESPONSIBILITY OR LIABILITY THEREFORE. THE CONTRACTOR SHALL INFORM ITSELF TO THE LOCATION OF ANY UTILITY LINE, PIPELINE OR UNDERGROUND UTILITY LINE IN OR NEAR THE AREA OF THE WORK IN ADVANCE OF AND DURING EXCAVATION WORK. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY AND ALL DAMAGE CAUSED BY IT'S FAILURE TO LOCATE, IDENTIFY AND PRESERVE ANY AND ALL EXISTING UTILITIES, LINES, PIPELINES, OR UNDERGROUND UTILITY LINES. THE CONTRACTOR SHALL COMPLY WITH STATE STATUTES, MUNICIPAL AND LOCAL ORDINANCES, RULES, AND REGULATIONS, IF ANY, PERTAINING TO THE LOCATION OF THESE LINES AND FACILITIES IN PLANNING AND CONDUCTING EXCAVATION, WHETHER BY CALLING OR NOTIFYING THE UTILITIES, COMPLYING WITH "NM ONE CALL" PROCEDURES, OR OTHERWISE. WARNING: KEYED NOTES 1. UTILITY-OWNED SERVICE TRANSFORMER. REFER TO POWER RISER DIAGRAM. 2. SERVICE ENTRANCE EQUIPMENT, REFER TO POWER RISER DIAGRAM. 3. METERING EQUIPMENT PER SERVING UTILITY COMPANY REQUIREMENTS. 4. POLE MOUNTED LIGHT FIXTURE. REFER TO POLE BASE DETAIL. EACH NEW CONCRETE BASE SHALL HAVE 1X1.25" BUSHED CONDUIT WITH MULE-TAPE MEASURING PULL-STRING EXTENDED TO CCTV HEAD-END LOCATION. REFER TO CCTV DETAIL FOR ADDITIONAL REQUIREMENTS. 5. DUAL PORT ELECTRIC VEHICLE CHARGER FURNISHED BY OWNER. COORDINATE EXACT PLACEMENT AND REQUIREMENTS PRIOR TO ROUGH-IN. EXTEND TWO SEPARATE 1.25" CONDUITS WITH (3) #2 CU AND (1) #8 CU EGR TO CIRCUIT(S) INDICATED. 6. CONTRACTOR IS RESPONSIBLE TO COMPLY WITH GFCI AND AFCI REQUIREMENTS INCLUDING SPD STANDARDS FOR RESIDENTIAL APPLICATIONS ON THIS PROJECT. PROVIDE AND INSTALL ANY NECESSARY ITEMS TO MEET CURRENT CODE. · PRIMARY UNDERGROUND SERVICE FEEDER. EXTEND 4" DUCT TO SERVICE POINT PER SERVING UTILITY COMPANY REQUIREMENTS. · SECONDARY ELECTRIC UNDERGROUND SERVICE LATERAL, REFER TO POWER RISER DIAGRAM. · TELEPHONE SERVICE PEDESTAL, VERIFY EXACT LOCATION IN FIELD WITH SERVING UTILITY REPRESENTATIVE. · 4" PVC CONDUIT FOR TELEPHONE/DATA SERVING UTILITY WITH MULE-TAPE MEASURING PULL STRING. COORDINATE EXACT ROUTING AND SERVICE POINT WITH UTILITY PROVIDER. · WEATHER RESISTANT GFCI RECEPTACLE WITH AUDIBLE ALARM INSTALLED IN WATER/IRRIGATION BACK-FLOW PREVENTER HOT-BOX. COORDINATE EXACT LOCATION PRIOR TO ROUGH-IN. EXTEND .75" CONDUIT WITH (2) #10 CU AND (1) #10 CU EGR TO CIRCUIT INDICATED. HOT-BOX AND HEAT-TAPE FURNISHED BY OTHERS. · WEATHER PROOF JUNCTION BOX SERVING SITE SIGNAGE. CONFIRM EXACT LOCATION PRIOR TO ROUGH-IN. EXTEND .75" CONDUIT WITH (2) #10 CU AND (1) #10 CU EGR TO CIRCUIT INDICATED, AND 1" BUSHED CONDUIT WITH MULE-TAPE MEASURING PULL-STRING TO IDF ROOM. · EXTEND TO CIRCUIT INDICATED UTILIZING #10 CU WIRING THROUGH-OUT ENTIRE CIRCUIT. ROUTE WIRING THROUGH LIGHTING CONTROLS FOR PROPER OPERATION IN COMPLIANCE WITH LOCAL NIGHT-SKY PARAMETERS. · FUTURE EVSE. PROVIDE 17X30 TIER 22 POLYMER CONCRETE PULL-BOXES WITH ETCHED LID "ELECTRIC". EXTEND TWO SEPARATE 1.25" BUSHED CONDUIT(S) TO PANEL INDICATED WITH MULE-TAPE MEASURING PULL-STRING FOR FUTURE USE. TEMPORARILY SEAL CONDUIT(S) AND REFER TO UG PULL-BOX DETAIL FOR ADDITIONAL REQUIREMENTS. · WEATHER PROOF JUNCTION BOX SERVING MOTORIZED GATE OPERATOR. COORDINATE EXACT LOCATION PRIOR TO ROUGH-IN. EXTEND .75" CONDUIT WITH (2) #10 CU AND (1) #10 CU EGR TO CIRCUIT INDICATED. · EXTEND 1" BUSHED CONDUIT WITH MULE-TAPE MEASURING PULL-STRING FROM IRRIGATION MANIFOLD TO IRRIGATION CONTROLLER LOCATION FOR CONTROL WIRING BY OTHERS. COORDINATE ROUTING AND REQUIREMENTS WITH LANDSCAPE INSTALLER PRIOR TO ROUGH-IN.2026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) O-01 WEM OC S O-02 WEM S OC O-01 O-04 RACK L6-30R PANEL "IT" s s s s O-04 WEM S O-02 A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING E-401 ENLARGED PLANS ELECTRICAL 25001 JT 25104_E-401 10/21/2026 10:19:32 AM D1 ENLARGED LIGHTING PLAN - OFFICE O-01 1/4" = 1'-0" A3 ENLARGED POWER PLAN - SECURITY O-02 1/4" = 1'-0" C3 ENLARGED LIGHTING PLAN - SECURITY O-02 1/4" = 1'-0" PLAN NORTH 0' 2' 4' 8' 1. EXTERIOR EMERGENCY EGRESS LIGHTING UNIT, TYPE "WEM", WITH EMERGENCY BATTERY PACK. REFER TO LUMINAIRE SCHEDULE. CONNECT TO UNSWITCHED (120V OR 277V) LIGHTING CIRCUIT SERVING ADJACENT INTERIOR ROOM U.N.O. 2. WALL MOUNT OCCUPANCY SENSOR. SENSOR SHALL AUTOMATICALLY TURN OFF LIGHTING WITHIN 20 MINUTES WITHOUT OCCUPANCY. 3. NUMBER ADJACENT TO RECEPTACLE INDICATES CIRCUIT NUMBER. SIZE CONDUCTORS ACCORDING TO CORRESPONDING BREAKER RATING AND MAKE ALL FINAL POWER CONNECTIONS. 4. SERVICE ENTRANCE EQUIPMENT, REFER TO POWER RISER DIAGRAM. 5. TELEPHONE TERMINAL CABINET (TTB) WITH DEDICATED QUADRUPLEX RECEPTACLE. REFER TO VOICE/DATA RISER DIAGRAM. 6. RACK MOUNTED DOUBLE DUPLEX RECEPTACLE. COORDINATE EXACT PLACEMENT WITH OWNER'S IT MANAGER PRIOR TO ROUGH-IN. 7. 30-AMP, 208-VOLT, RACK MOUNTED RECEPTACLE FOR OWNER FURNISHED UPS. FURNISH RECEPTACLE WITH NEMA CONFIGURATION COMPATIBLE WITH OWNER'S EQUIPMENT. KEYED NOTES: PLAN NORTH 0' 2' 4' 8' C1 ENLARGED POWER PLAN - OFFICE O-01 1/4" = 1'-0" PLAN NORTH 0' 2' 4' 8' B1 ENLARGED POWER PLAN - IT O-04 1/4" = 1'-0" A1 ENLARGED LIGHTING PLAN - IT O-04 1/4" = 1'-0" PLAN NORTH 0' 2' 4' 8' PLAN NORTH 0' 2' 4' 8' PLAN NORTH 0' 2' 4' 8' 4 4 1 2 4 5 1 4 2 1 42026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) O-03 LL C-01PANEL "C01" O-03 WEM S OC LL C-01 WEM SOC S WEM OC PANEL "C01" A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING E-402 ENLARGED PLANS ELECTRICAL 25001 JT 25104_E-402 10/21/2026 10:19:54 AM A1 ENLARGED POWER PLAN - OFFICE O-03 1/4" = 1'-0" A3 ENLARGED POWER PLAN - COMMUNITY C-01 1/4" = 1'-0" PLAN NORTH 0' 2' 4' 8' 1. EXTERIOR EMERGENCY EGRESS LIGHTING UNIT, TYPE "WEM", WITH EMERGENCY BATTERY PACK. REFER TO LUMINAIRE SCHEDULE. CONNECT TO UNSWITCHED (120V OR 277V) LIGHTING CIRCUIT SERVING ADJACENT INTERIOR ROOM U.N.O. 2. WALL MOUNT OCCUPANCY SENSOR. SENSOR SHALL AUTOMATICALLY TURN OFF LIGHTING WITHIN 20 MINUTES WITHOUT OCCUPANCY. 3. NUMBER ADJACENT TO RECEPTACLE INDICATES CIRCUIT NUMBER. SIZE CONDUCTORS ACCORDING TO CORRESPONDING BREAKER RATING AND MAKE ALL FINAL POWER CONNECTIONS. 4. SERVICE ENTRANCE EQUIPMENT, REFER TO POWER RISER DIAGRAM. KEYED NOTES: PLAN NORTH 0' 2' 4' 8' B1 ENLARGED LIGHTING PLAN - OFFICE O-03 1/4" = 1'-0" PLAN NORTH 0' 2' 4' 8' B3 ENLARGED LIGHTING PLAN - COMMUNITY C-01 1/4" = 1'-0" PLAN NORTH 0' 2' 4' 8' 1 2 4 1 1 2 2 42026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) HB C-02 FE HB PANEL "C02" HB C-02 FE HB WEM WEM OC S OC S C-03 FE WEM OC S WEM OC S C-03 FE PANEL "C03" A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING E-403 ENLARGED PLANS ELECTRICAL 25001 JT 25104_E-403 10/21/2026 10:20:16 AM A1 ENLARGED POWER PLAN - COMMUNITY C-02 1/4" = 1'-0" C1 ENLARGED LIGHTING PLAN - COMMUNITY C-02 1/4" = 1'-0" A3 ENLARGED POWER PLAN - COMMUNITY C-03 1/4" = 1'-0" C3 ENLARGED LIGHTING PLAN - COMMUNITY C-03 1/4" = 1'-0" PLAN NORTH 0' 2' 4' 8' PLAN NORTH 0' 2' 4' 8' PLAN NORTH 0' 2' 4' 8' PLAN NORTH 0' 2' 4' 8' 1. EXTERIOR EMERGENCY EGRESS LIGHTING UNIT, TYPE "WEM", WITH EMERGENCY BATTERY PACK. REFER TO LUMINAIRE SCHEDULE. CONNECT TO UNSWITCHED (120V OR 277V) LIGHTING CIRCUIT SERVING ADJACENT INTERIOR ROOM U.N.O. 2. WALL MOUNT OCCUPANCY SENSOR. SENSOR SHALL AUTOMATICALLY TURN OFF LIGHTING WITHIN 20 MINUTES WITHOUT OCCUPANCY. 3. NUMBER ADJACENT TO RECEPTACLE INDICATES CIRCUIT NUMBER. SIZE CONDUCTORS ACCORDING TO CORRESPONDING BREAKER RATING AND MAKE ALL FINAL POWER CONNECTIONS. 4. SERVICE ENTRANCE EQUIPMENT, REFER TO POWER RISER DIAGRAM. 5. RECEPTACLE LOCATED BEHIND WATER COOLER. VERIFY EXACT LOCATION WITH MECHANICAL PRIOR TO ROUGH-IN (ADJUST AS NECESSARY IF EXISTING). CONNECT TO GFCI BREAKER RATED FOR PERSONNEL PROTECTION IN COMPLIANCE WITH NEC 422.5(A) AND (B). KEYED NOTES: 4 5 1 1 2 2 1 1 2 2 42026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING E-501 DETAILS ELECTRICAL 25001 JT 25104_E-501 10/21/2026 10:20:35 AM 60" FINISHED GRADE 24" 20" DIA. POLE BASE MOUNTING DETAIL SCALE: NONE BOTH POLE AND BASE PLATE SHALL BE FURNISHED AS PART OF LUMINAIRE, REFER TO LUMINAIRE SCHEDULE HANDHOLE INSTALL BUSHING ON CONDUIT ENDS 3000 PSI CONCRETE #5 VERTICAL REBAR WITH #4 HORIZONTAL REBAR TIES 12" ON CENTER. FIRST TIE SHALL BE 6" FROM BOTTOM. BOLTS FURNISHED AS PART OF LUMINAIRE. INSTALL PER MANUFACTURER. ELECTRICAL CONDUIT, SEE ELECTRICAL SITE PLAN FOR ROUTING A ALL LIGHT POLE CONCRETE BASES SHOULD BE VERIFIED WITH STRUCTURAL ENGINEER FAMILIAR WITH THE SOIL AND WIND CONDITIONS OF THIS PROJECT. B G.C. TO PROVIDE AND INSTALL ENTIRE POLE BASE. C LIGHTING FIXTURES SHALL BE OF TYPE INDICATED ON DRAWINGS. POLE BASE NOTES: ELECTRICAL CONDUIT, SEE ELECTRICAL SITE PLAN FOR ROUTING 18" X 18" X 18" 3000 PSI CONCRETE CUBE, CHAMFER EDGE 1" CONTINUOUS AT BASE FINISHED GRADE INSTALL BUSHING ON CONDUIT ENDS FIXTURE POLE AND BASE PLATE FURNISHED AS PART OF FIXTURE, REFER TO LIGHTING FIXTURE SCHEDULE BOLLARD FIXTURE BASE DETAIL SCALE: NONE A ALL LIGHT POLE CONCRETE BASES SHOULD BE VERIFIED WITH STRUCTURAL ENGINEER FAMILIAR WITH THE SOIL AND WIND CONDITIONS OF THIS PROJECT. B G.C. TO PROVIDE AND INSTALL ENTIRE POLE BASE. C LIGHTING FIXTURES SHALL BE OF TYPE INDICATED ON DRAWINGS. POLE BASE NOTES: COVER SURFACE SKID RESISTANT PULL SLOTS (2) WITH WASHER (2) 9MM - 16NC HEX BOLTS TRAFFIC RATED COVER PULL BOX DETAIL GRADE AS REQUIRED WITH COVER LOGO AND EXTENSIONS QUAZITE "PG" STYLE PULLBOX 8" POINTS TO SERVICE WITH GRAVEL FILL BOTTOM EXTENSION 24" MIN. PULLBOX TO NEXT PULLBOX ELEVATION DETAIL UG PULL BOX DETAIL SCALE: NONE NUMBER ADJACENT TO JACK SYMBOL INDICATES NUMBER OF CABLES / PORTS. QUADPLEX RECEPTACLE TO DEDICATED 120V CIRCUIT #6 GROUND T VOICE/DATA RISER DIAGRAM SCALE: NONE T CONTRACTOR SHALL COORDINATE WITH SERVING UTILITY COMPANY(S) FOR NEW TELEPHONE/DATA SERVICE SPECIFIC TO THIS PROJECT PRIOR TO BIDDING, ORDERING, OR COMMENCING WITH THE TELEPHONE/DATA SERVICE(S) PORTION OF THIS PROJECT. WAP1 2 4 2 A A B A BELOW GRADE OPTION TELEPHONE SERVICE CONDUIT, 4" SCHEDULE 40, UTILIZE RGC ELBOWS BUSH CONDUIT END EXTEND TO ELECTRICAL SERVICE EQUIPMENT IN 1/2" CONDUIT 12"X4"X1/4" GROUND BAR ABOVE GROUND OPTION 4" TELEPHONE SERVICE CONDUIT, EXTEND TO TELEPHONE SERVICE POINT UTILIZE RGC CONDUIT REQUIRES SERVING UTILITY'S CONSENT 4' X 8' X 3/4" PLYWOOD TERMINAL BACKBOARD (TTB) BY G.C., PAINTED WHITE BUSH CONDUIT END .75" BUSHED CONDUIT 1" BUSHED CONDUIT CABLE AND TERMINATIONS BY OTHERS CONDUIT FROM OUTLET TO TTB, OR STUB CONDUIT INTO ACCESSIBLE CEILING IF CABLING CAN BE EXTENDED DIRECTLY TO TTB. A B GROUND BUSBAR DETAIL HOLES 15/32" DIA. STAND-OFF (FRONT VIEW) 2 1/8" 12 @ 1" 0.C (TOP VIEW) AS REQUIRED LUG QUANTITY 1" STAND-OFF GROUNDING 1/4"x4"x24" PLATE 2 1/8" 1"2" P-1000 UNISTRUT FRAMING SCALE: NONE UNLESS NOTED OTHERWISE COPPER TO GROUNDING ELECTRODE AT ELECTRICAL SERVICE ACCESS CONTROLS SYSTEM DIAGRAM SCALE: NONE ACCESS CONTROL POWER SUPPLIES, CONTROLLERS CR CR 3/4" 1/2" 1/2" 3/4" 3/4" J-BOX J-BOX DOOR POSITION SWITCH J JCAT-6 CAT-6 CAT-6 CAT-6 ELECTRIC STRIKE, MAG LOCK, REQUEST TO EXIT, PANIC HARDWARE, BY DOOR HARDWARE CONTRACTOR ELECTRIC STRIKE, MAG LOCK, REQUEST TO EXIT, PANIC HARDWARE, BY DOOR HARDWARE CONTRACTOR DOOR POSITION SWITCH SUPPLEMENTAL LINE VOLTAGE POWER (WHEN REQUIRED) CARD READER CARD READER VIDEO INTERCOM STATION CONNECT TO CIRCUIT INDICATED. REFER TO POWER PLAN OR PANEL SCHEDULE(S) COMPOSITE PLENUM CABLE TO EACH DOOR CONTROLLER LOCATION (TYP) NOTE: COORDINATE EXACT CONDUIT REQUIREMENTS WITH OWNER'S VENDOR PRIOR TO ROUGH-IN. I.T. ROOM LADDER RACK SYSTEM TYPICAL COMPONENTS DETAIL SCALE: NONE CABLE TRAY, LADDER OR BASKET TYPE AS NOTED EQUIPMENT CABINET (GENERIC, TYPICAL) EQUIPMENT RACK (GENERIC, TYPICAL) WALL-MOUNT RACK OR CABINET (GENERIC, TYPICAL) RADIUS DROP KIT PROVIDED OVER RACK NOTE: NOT ALL COMPONENTS MAY BE APPLICABLE, REFER TO JOB SPECIFIC I.T. ROOM LAYOUT. (TYPICAL) A. DIMENSIONS VARY; REFER TO ELECTRICAL SITE PLAN FOR SIZE(S). CONTRACTOR SHALL ADJUST PULL BOX DIMENSIONS AND MAINTAIN NEC COMPLIANCE WHEN CONDUITS ARE ADDED OR INCREASED FOR VOLTAGE DROP. B. TIER RATINGS SHALL BE ACCORDING TO PEDESTRIAN/VEHICLE TRAFFIC LOCATIONS.2026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING E-601 DIAGRAM, SERVICE CALCS RISER 25001 JT 25104_E-601 10/21/2026 10:20:56 AM SCALE: N.T.S. POWER RISER DIAGRAM SERVICE CHARACTERISTICS: 208V, 3-PHASE, 4-WIRE, 60 Hz CONNECTED LOADS: 628.2 KVA ( 1741 AMPS) FUTURE LOADS: 0 KVA ( 0 AMPS) ESTIMATED DEMAND: 282.7 KVA ( 783.1 AMPS) RECOMMEND SERVICE TRANSFORMER BE SIZED AT 500 KVA SHORT-CIRCUIT CALCULATIONS MAXIMUM FAULT CURRENT AT TRANSFORMER SECONDARY = USE 60,000A PER UTILITY STANDARDS DM-4-11.0. ALL PANELS SHALL HAVE A.I.C. AS SCHEDULED. SERVICE SIZING CALCULATIONS SIDE VIEW SECTION 110-26 WORKING SPACE 3'- 4' 6-1/2 FT MINIMUM CEILING STRUCTURAL STRUCTURAL CEILING SIDE VIEW PANEL (OK) WALL SECTION 110-16 SPACE PANEL 30" FRONT VIEW FRONT VIEW PANEL PIPE PIPE (OK) POWER PANEL CLEARANCE DIAGRAM SCALE: NONE PANEL N SERVICE FEEDER NEUTRAL BUS GROUND BUS A. ALL CONDUCTORS USED FOR THE GROUNDING SYSTEM SHALL BE COPPER. B. CONNECT THE GROUNDING SYSTEM TO THE FOUR FOLLOWING COMPONENTS IF AVAILABLE: 1. BUILDING STEEL. 2. METAL U.G. COLD WATER PIPE. 3. CONCRETE ENCASED REBAR OR #4 COPPER UFER. 4. 10' GROUND RODS. C. ANY SPLICING SHALL BE VIA IRREVERSIBLE COMPRESSION TYPE. D. THE GROUNDING SYSTEM SHALL COMPLY WITH ALL REQUIREMENTS OF ARTICLE 250 NEC, AND SHALL PROVIDE 5 OHMS OR LESS RESISTANCE TO GROUND. PROVIDE TEST REPORT VERIFYING RESISTANCE LEVEL IS IN COMPLIANCE WITH 5 OHM MAXIMUM. SERVICE GROUNDING SYSTEM DIAGRAM SCALE: NONE SERVICE ENTRANCE EQUIPMENT MAIN PANELBOARD SERVICE GROUNDING SYSTEM GENERAL NOTES PHASE BUSES NEUTRAL BUS GROUND BUS INTERSYSTEM BONDING TERMINATION (IBT), NEC 250.94 #6 CU 200A 225A 400A 600A 800A 150A 100A SERVICE AMPACITY METALLIC PIPE CONDUCTOR BUILDING STEEL CONDUCTOR #4 #2 #1/0 #2/0 #3/0 #6 #8 #4 #2 #1/0 #2/0 #3/0 #6 #8 #4 #2 #1/0 #2/0 #2/0 #6 #8 #4 #2 #1/0 #2/0 #2/0 #6 #8 REBAR OR UFER CONDUCTOR #4 #6 #8 GROUND ROD CONDUCTOR #6 #8 EQUIV. CU WIRE SIZE #3/0 #4/0 #600 (2) X 350 (2) X 600 #1/0 #2 MAIN BONDING JUMPER EQUIPMENT BONDING JUMPER GROUNDING ELECTRODE CONDUCTOR SCHEDULE #4 #4 #4 #4 #6 #6 #6 #6 #6 NOTE: COORDINATE EQUIPMENT INSTALLATION IN FIELD TO ENSURE ALL N.E.C. CLEARANCES ARE MAINTAINED SURFACE MOUNTED PANEL PANEL FOOTPRINT CLEAR, FLOOR TO CEILING (NO PIPING OR DUCTWORK OF ANY KIND) SUSPENDED CEILING LIGHTING FIXTURE (OK) EXCLUSIVELY DEDICATED SPACE LIGHTING FIXTURE (OK) LIGHTING FIXTURE (OK) SUSPENDED CEILING WALL DRIVEN 5/8" X 10' COPPER CLAD GROUND ROD (SPACED 20' APART PER NMEC) COLD WATER PIPE, NEC 250.52(1) SLAB REBAR OR #4 UFER GROUND, NEC 250.52(3) BUILDING STEEL, NEC 250.52(2) COPPER SERVICE GROUNDING ELECTRODE CONDUCTOR, MINIMUM SIZE AS SHOWN ON GROUNDING ELECTRODE CONDUCTOR SCHEDULE EQUIP. BONDING JUMPER, NEC 250.102(C) MAIN BONDING JUMPER, NEC 250.28 KEYED NOTES · CONCRETE EQUIPMENT PAD HAVING DIMENSIONS 4" LARGER THAN EQUIPMENT SERVED INSTALLED ON LEVEL SOIL COMPACTED TO 95%. COMPLY WITH NEC 110.26(A)(3). REFER TO STRUCTURAL FOR EXACT REQUIREMENTS AND CIVIL FOR ACTUAL FINISHED ELEVATION. A. CONTRACTOR SHALL PROVIDE ALL PLACARDS AND WARNING SIGNS REQUIRED BY THE NEC AND THE AGENCY HAVING JURISDICTION. B. PRIOR TO ORDERING DISTRIBUTION EQUIPMENT, OR COMMENCING WITH INSTALLATION, CONTRACTOR SHALL GENERATE A SCALED DRAWING BASED ON ACTUAL EQUIPMENT MANUFACTURER(S) DIMENSIONS TO AVOID CONFLICTS WITH OTHER TRADES, ABOVE AND BELOW GRADE, INCLUDING WORKING CLEARANCES. GENERAL NOTES 1. EXISTING UTILITY OIL-FILLED TRANSFORMER AND CONCRETE PAD, PROVIDE PROTECTIVE STEEL BOLLARDS AS REQUIRED BY THE SERVING UTILITY. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH UTILITY TO COMPLY WITH PROJECTED LOAD CALCULATIONS. INCREASE SERVICE SIZE TO ACCOMMODATE IF NEEDED. 2. METER ENCLOSURE PER PNM MS-2-7.0 OR AS REQUIRED BY SERVING UTILITY. 3. EXISTING UTILITY PRIMARY. 4. PANELBOARD. REFER TO SCHEDULE FOR ADDITIONAL REQUIREMENTS. 5. GROUNDING ELECTRODES AS PRESCRIBED BY NEC 250. IF ONE OR MORE OF THE PRESCRIBED ELECTRODES ARE ABSENT (OR NOT ACCESSIBLE) CONTRACTOR SHALL COMPLY WITH NM STATE CODE NMAC 14.10.4 ARTICLE 250.50. 6. OWNER PROVIDED LEVEL II, DUAL-PORT, VEHICLE CHARGER. VERIFY EXACT PLACEMENT AND REQUIREMENTS WITH OWNER PRIOR TO ROUGH-IN. BASIS OF DESIGN IS CHARGE POINT CP6000 SERIES NETWORKED CHARGING STATION. 60,000A PANEL "IT" 3 2 1 PANEL "DP1" PANEL "DP2" PANEL "CO1" PANEL "SE SITE" EVSE 6 NEW MDP 2000 AMP SPD 30A WEST GATE OPENER 2000A/3P 60A/3P 80A/2P 30A/2P 800A/3P 800A/3P 90A/3P 200A/3P 200A/3P 100A/3P 100A/3P PROVISION SPARE PROVISION 65,000A 208/120V 3Ø 4 WIRE 5 4 PANEL "DP2" PANEL "DP1" PANEL "C02" PANEL "SLEEP1" PANEL "L01" PANEL "L01" PANEL "B01" PANEL "B02" PANEL "B03" A B 800A 208/120V 3Ø 4W 200A/2P 200A/2P 200A/2P 200A/2P 175A/2P 175A/2P 175A/2P 4 PANEL "SLEEP2" PANEL "SLEEP3" PANEL "C03" PANEL "L02" PANEL "L02" PANEL "B04" PANEL "B05" A B PANEL "B06" PANEL "SEC" 800A 208/120V 3Ø 4W 4 200A/2P 200A/2P 150A/2P 200A/2P 200A/2P 175A/2P 175A/2P 150A/2P 175A/2P2026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING E-602 SCHEDULES PANEL 25001 JT 25104_E-602 10/21/2026 10:21:23 AM2026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING P-001 LEGEND & GENERAL NOTES PLUMBING 25001 EJP 25104_P-001 10/21/2026 10:24:35 AM A. ALL PIPING SHALL BE CONCEALED WHERE POSSIBLE. ALL EXPOSED PIPING, WHERE CONCEALMENT IS NOT POSSIBLE, SHALL BE INSTALLED AND PAINTED AS DIRECTED BY THE ARCHITECT. B. ALL PIPING SHALL BE INSULATED, SEE SPECIFICATIONS. C. ALL BRANCHES SHALL BE VALVED AND ALL VALVES SHALL HAVE UNIONS ADJACENT. ACCESS PANELS AND DOORS SHALL BE FURNISHED TO GENERAL CONTRACTOR FOR INSTALLATION AND ACCESS TO VALVES WHERE REQUIRED. LOCATE ADDITIONAL VALVES AS SHOWN ON DRAWINGS. SEE SPECIFICATIONS FOR ACCESS DOOR REQUIREMENTS. D. ALL PIPING SHALL PITCH TO DRAIN, AND CONTRACTOR SHALL PROVIDE VALVING FOR SYSTEM DRAINAGE. CONTRACTOR SHALL DELIVER A MARKED-UP SET OF PLANS TO THE OWNER (PRIOR TO FINAL PAYMENT) SHOWING ALL BRANCH VALVES AND ALL DRAINAGE POINTS. E. CARE SHALL BE TAKEN TO AVOID MECHANICAL DUCTWORK, ELECTRICAL EQUIPMENT AND AIR HANDLING EQUIPMENT ABOVE CEILING. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ROUTING OF PIPING WITH CEILING CONTRACTOR AND SHEET METAL CONTRACTOR. RELOCATION OF PIPING AS A RESULT OF POOR COORDINATION BY THIS CONTRACTOR SHALL BE AT HIS OWN EXPENSE. F. NO WATER PIPING SHALL BE LOCATED IN OUTSIDE WALLS, UNLESS SHOWN TO BE AND THEN PIPING TO BE INSULATED AND LOCATED AS CLOSE AS POSSIBLE TO INSIDE OF WALL CAVITY WITH ADDITIONAL INSULATION BETWEEN PIPING AND EXTERIOR OF WALL. G. WRITTEN PRIOR APPROVAL REQUIRED FOR ALL PROPOSED SUBSTITUTIONS OF EQUIPMENT AND MATERIALS, RECEIVED BY ENGINEER, 10 DAYS PRIOR TO BID DATE OF PROJECT TO ALLOW ADEQUATE TIME FOR REVIEW AND RESPONSE. H. ALL TRENCHING AND BACKFILL FOR PIPING SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR. I. ALL SEWER PIPING BELOW FLOOR SLAB (BELOW GRADE) SHALL BE STANDARD WEIGHT HUB AND SPIGOT CAST IRON. J. ALL PIPE PENETRATIONS THRU FIRE-RATED ASSEMBLIES SHALL BE SLEEVED AND SEALED WITH CODE-APPROVED FIRE BARRIER MATERIALS. K. SECURE ALL PIPING TO WALLS FOR A RIGID INSTALLATION WITH UNISTRUT BRACKETS AND GASKETED PIPE CLAMPS. PLUMBING GENERAL NOTES A. CONTRACTOR SHALL VERIFY LOCATION OF ALL PIPING, EQUIPMENT, ETC. SERVED BY EXISTING EQUIPMENT TO BE REMOVED. CONTRACTOR SHALL REMOVE SUCH ITEMS ONLY IF THEY DO NOT SERVE FIXTURES TO REMAIN. ALL PIPING SHALL BE CAPPED IN A CONCEALED LOCATION. B. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING AND FINISHING SURFACES (WALLS, FLOORS, CEILINGS) DAMAGED DURING REMOVAL OF EQUIPMENT AND PIPING UNLESS REMOVAL OR RENOVATION OF SURFACE IS COVERED UNDER ANOTHER SECTION OF THIS CONTRACT. C. CONTRACTOR SHALL DISPOSE OF OR RETURN ALL PLUMBING FIXTURES, PIPING, ETC. TO OWNER IN ACCORDANCE WITH DIRECTION OF THE ARCHITECT. D. REMOVE ANY COLD WATER, HOT WATER, GAS, WASTES OR VENT PIPING (NOT SHOWN) UNCOVERED IN EXISTING PARTITIONS TO BE REMOVED; REMOVE BACK TO ACTIVE LINE AND CAP. E. PLUG OR SEAL ALL SOIL, WASTE AND VENT OPENINGS AS DIRECTED FOR A SMOOTH FINISH FLOOR. F. PIPE ROUTING IS APPROXIMATE ONLY; EACH BIDDER SHALL SATISFY HIMSELF AS TO EXISTING BUILDING CONDITIONS BEFORE SUBMITTING HIS BID. NO ALLOWANCE SHALL BE MADE AFTER CONTRACT IS AWARDED TO ALLOW FOR LACK OF PRE-BID INSPECTION OF BUILDING BY SUCCESSFUL BIDDER. G. COORDINATE WORK WITH OTHER TRADES TO MINIMIZE CONFLICTS AND "DOWN TIME". DEMOLITION GENERAL NOTES PLUMBING SHEET INDEX EQUIPMENT DESIGNATION KEYED NOTES Ø PLUMBING SYMBOL LEGEND ABBR. SYMBOL DESCRIPTION (E) EXISTING (TYP) TYPICAL BTU BRITISH THERMAL UNITS CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE ELV ELEVATION EWT ENTERING WATER TEMPERATURE FFE FINISH FLOOR ELEVATION ESP EXTERNAL STATIC PRESSURE HP HORSE POWER INV INVERT ELEVATION LWT LEAVING WATER TEMPERATURE NA NOT APPLICABLE NC NORMALLY CLOSED GPH GALLONS PER HOUR DIA DIAMETER NO NORMALLY OPEN PH PHASE PSIG POUNDS PER SQUARE INCH R REGISTER WITH OBD SP STATIC PRESSURE °F DEGREES FAHRENHEIT BUTTERFLY VALVE POINT OF CONNECTION CAP ON END OF PIPE CONTINUATION OF PIPE SHUT OFF (BALL, GATE, BUTTERFLY) GLOBE VALVE CHECK VALVE PLUG VALVE TEMPERATURE CONTROL VALVE (2-WAY) TEMPERATURE CONTROL VALVE (3-WAY) PRESSURE REDUCING VALVE SOLENOID VALVE DOUBLE CHECK BACKFLOW PREVENTER PIPE ANCHOR SAFETY RELIEF VALVE PRESSURE GAUGE WITH PIG TAIL AND COCK THERMOMETER STRAINER WITH BLOW-OFF VALVE SHOCK ABSORBER FLOW SWITCH FLOOR DRAIN FLOOR SINK BALANCING VALVE S BALL VALVE UNION RELIEF VALVE 1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONS ON LEGEND SHEET ARE NOT NECESSARILY USED ON THIS PROJECT. 2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES AND NOTATION CONVENTIONS OCCURRING IN THIS DRAWING SET ARE NECESSARILY DEFINED ON THESE LEGENDS. CONSULT THE ENGINEER IN THE EVENT SYMBOLOGY OR NOTATION INTERPRETATION IS REQUIRED. NOTES FCO FLOOR CLEAN OUT FLANGED CONNECTION WALL CLEANOUTWCO VTR VENT THRU ROOF RISER DOWN RISER UP DROP RISER UP HOSE BIBB / WALL HYDRANTHB PIPE GUIDE DIRECTION OF FLOW VALVE IN RISER ABBR. SYMBOL DESCRIPTION CWR CWS G CA C G NATURAL GAS PIPING C CWR COLD WATER RETURN CWS COLD WATER SUPPLY CA COMPRESSED AIR STEAM CONDENSATE PIPING - BLACK STEEL SCHED. 80 FF FIRE PROTECTION/LINE CW COLD WATER LINE HW HOT WATER LINE V VENT PIPING FOSFOS FUEL OIL SUPPLY FORFOR FUEL OIL RETURN FOVFOV FUEL OIL VENT FOFFOF FUEL OIL FILL AWAW ACID WASTE PIPE AVAV ACID VENT PIPE GWGW GREASE WASTE PIPE GVGV GREASE VENT MU MPG HWR HWS MPG MEDIUM PRESSURE GAS PIPING (2 PSI) HWR HOT WATER RETURN PIPING - COPPER TYPE "L" MU MAKE-UP WATER PIPING HWS HOT WATER SUPPLY PIPING - COPPER TYPE "L" OFL OVERFLOW LEADEROFL NPWNPW NON POTABLE WATER PIPING SS SANITARY SEWER OR WASTE LINE WW COLD WATER SUPPLY MPRMPR MEDIUM PRESSURE CONDENSATE RETURN PCPC PUMP CONDENSATE PWPW PRESSURIZED WASTE LPGLPG LIQUID PROPANE GAS MA NO N MV WAGD DA DV MA MEDICAL AIR N NITROGEN NO NITRUS OXIDE WAGD DV DENTAL VACUUM DA MV MEDICAL VACUUM DENTAL AIR WASTE ANESTHESIA GAS DISPOSAL O OXYGENO IAIA INSTRUMENT AIR CA AR CO2 HE LN LOX O CA COMPRESSED DRY AIR CO2 CARBON DIOXIDE AR ARGON LN O OXYGEN LOX HE HELIUM LIQUID OXYGEN LIQUID NITROGEN AC ACETYLENEAC HH HYDROGEN GG NATURAL GAS PIPING SS SANITARY SEWER OR WASTE LINE WW COLD WATER SUPPLY FF FIRE PROTECTION/LINE SDSD STORM DRAIN IRRIRR IRRIGATION VALVE WITH VALVE BOX FIRE HYDRANT FIRE DEPARTMENT INLET CONNECTION THRUST BLOCK FENCING POWER POLE / LIGHT POLE SANITARY MANHOLEMH S MH ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION PLUMBING PIPING DESIGNATION SITE UTILITY SYMBOLS PROCESS GAS DESIGNATION MEDICAL GAS DESIGNATION XX X DEMOLISHED ITEM 1. P-001 PLUMBING LEGEND & GENERAL NOTES 2. PS-101 PLUMBING SITE PLAN 3. P-401 PLUMBING ENLARGED PLANS 4. P-501 PLUMBING DETAILS PLUMBING FIXTURE/EQUIPMENT SCHEDULE SYMBOL DESCRIPTION EWH-1 ELECTRIC WATER HEATER: A.O. SMITH MODEL DEL-20. 20 GAL STORAGE, 14 GPH RECOVERY @ 90°F RISE, 120V, 1 PH, ELEMENT WATTAGE (3000). TRAP: - VENT: - CW: 3/4" HW: 3/4" ET-1 EXPANSION TANK: AMTROL ST-5. 2.0 GAL TOTAL VOLUME, 0.9 GAL MAX ACCEPTANCE. TRAP: - VENT: - CW: 3/4" HW: - SK-1 DOUBLE SINK: DESCRIPTION TRAP: 1/1/2" VENT: 1-1/2" CW: 1/2" HW: 1/2" MB-1 MOP BASIN: FIAT MODEL MSB2424, SIZE 24" X 24" X 10" DEEP, CONSTRUCTED OF MOLDED STONE, UNIT SHALL HAVE 10" HIGH WALLS, NOT LESS THAN 1" WIDE SHOULDERS, COMPLETE WITH FACTORY INSTALLED DRAIN BODY WITH QDC-3 JOINT CONNECTOR, NEOPRENE GASKETS AND COMBINATION DOME STRAINER-LINT BASKET CONSTRUCTED OF 302 16-GAUGE STAINLESS STEEL, T&S BRASS NO. B-0665-BSTP FAUCET WITH VACUUM BREAKER, INTEGRAL STOP WALL BRACE, PAIL HOOK AND 3/4" HOSE THREAD ON SPOUT AND #889-CC MOP HANGER. TRAP: 3" VENT: 2" CW: 1/2" HW: 1/2" DF-1 DRINKING FOUNTAIN (BI-LEVEL): ELKAY MODEL VRCTLDDSC. BI-LEVEL DRINKING FOUNTAIN, NON-REFRIGERATED, NON-FILTERED. FLOOR MOUNT CARRIER ZURN, WADE, JOSAM OR SMITH. TRAP: 1-1/4" VENT: 1-1/2" CW: 1/2" HW: - HB-1 HOSE BIBB: WOODFORD MODEL 24. ANTI-SIPHON, VACUUM BREAKER. PROVIDE WINTERIZATION VALVE UPSTREAM ON BRANCH SERVING HOSE BIBB. TRAP: - VENT: - CW: 3/4" HW: - RDRD ROOF DRAIN LEADER ORD OVERFLOW ROOF DRAINORD U.N.O. UNLESS NOTED OTHERWISE2026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) RIGHT OF WAY + UTILITY EASEMENT LL LL LL LL LL LL HB HB HB LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL C-02 B-05 B-01 B-02 B-03 ADA L-01 L-02 B-06 ADA B-04 RIM. EL 6624.81 INV. IN. EL 6618.21 INV. OUT. EL 6618.21 RIM. EL 6621.99 INV. IN. EL 6613.96 INV. OUT. EL 6613.64 I.E. = 98.00' (6628.00'?) FINISH GRADE = 100.00' (6630.00?) 1 S-23 S-24 S-18 S-19S-17S-16S-15 S-21 S-22S-20 S-14S-03S-02S-01 O-01 S-04 S-05 STORAGE C-01 O-02 S-06 S-10 S-11 S-07 S-08 ADA S-12 ADA S-13 S-09 STORAGESTORAGESTORAGE O-04 IT O-03 S-25 S-31 S-32 S-33 S-27S-26 S-28 ADA S-34 ADA S-29 S-30 S-36S-35 1 1 1 1 1 1 1 1 11 1 1 1 2" 2" 2" 2" 1" 2" 1-1/2" 1 1 1 1 1 I.E. = 88.23' (6618.23'?) 1/4" PER 1'-0" 1/4" PER 1'-0" 1/4" PER 1'-0" 1/4" PER 1'-0" 1/4" PER 1'-0" 2 S SS SS S S CW CW CW CW A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING A1 SITE PLAN - PLUMBING 1" = 20'-0" PLAN NORTH 0' 10' 20' 40' 1. 4" CLEANOUT TO GRADE, REFER TO DETAIL ON P-501. 2. 2" BACKFLOW PREVENTOR & HOTBOX ENCLOSURE. A. REFER TO SHEET P-501 FOR DETAILS. B. REFER TO SHEET P-001 FOR GENERAL NOTES, LEGEND & SCHEDULES. KEYED NOTES GENERAL NOTES PS-101 SITE PLAN PLUMBING 25001 EJP WAY 10/21/2026 10:24:56 AM 25104_PS-1012026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) B-05 L-02 B-06 ADA B-04 4" COTG 1-1/4" 1" 1" 1" HB-1 4" COTG 4" COTG 4" COTG 1-1/4" 1-1/2" 4" 4" 4" 4" 4" CW CW B-01 B-02 B-03 ADA L-01 4" COTG 4" COTG 1-1/4" 1" 1" 1" HB-1 4"4" I.E. = 98.00' 4" COTG 4" COTG 1-1/4"1-1/2"2" 4" 4" CWCW C-02 SK-1 DF-1 MB-1 EWH-1 ET-1 HB-1 4" COTG 4" COTG 1" 4" A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING 1. LAUNDRY SHELTER CONTAINS (1) 2" SINK DRAIN, (2) 2" WASHER STANDPIPE DRAINS, AND (1) 2" FLOOR DRAIN (LOCATIONS SHOWN ARE APPROXIMATED). ROUTE AND CONNECT TO 4" SANITARY LINE BELOW GRADE. 2. ACCESSIBLE + HALF BATH SHELTER CONTAINS (2) 3.5" TOILET DRAINS, (2) 2" LAVATORY DRAINS, (1) 2" SHOWER DRAIN, AND (2) 2" FLOOR DRAINS (LOCATIONS SHOWN ARE APPROXIMATED). ROUTE AND CONNECT TO 4" SANITARY LINE BELOW GRADE. 3. TWO-STALL SHELTER CONTAINS (2) 3.5" TOILET DRAINS, (2) 2" LAVATORY DRAINS, (2) 2" SHOWER DRAINS, AND (2) 2" FLOOR DRAINS (LOCATIONS SHOWN ARE APPROXIMATED). ROUTE AND CONNECT TO 4" SANITARY LINE BELOW GRADE. 4. DOMESTIC WATER LINE UP FROM BELOW GRADE, CONNECT TO SHELTER WATER CONNECTION POINT, INSULATE EXPOSED PIPING PER SPECIFICATIONS. 5. INSTALL HB-1 ONTO SHELTER BUILDING, CONNECT INTO 3/4" LINE INSIDE OF BUILDING. PROVIDE WINTERIZATION VALVE AND SLOPE WATER PIPING DOWNSTREAM OF VALVE TO DRAIN OUT OF HB-1. A. REFER TO SHEET P-501 FOR DETAILS. B. REFER TO SHEET P-001 FOR GENERAL NOTES, LEGEND & SCHEDULES. KEYED NOTES GENERAL NOTES C1 ENLARGE PLUMBING GROUP - EAST SIDE 1/4" = 1'-0" PLAN NORTH 0' 2' 4' 8'A1 ENLARGE PLUMBING GROUP - WEST SIDE 1/4" = 1'-0" PLAN NORTH 0' 2' 4' 8' P-401 ENLARGED PLANS PLUMBING 25001 EJP 25104_P-401 10/21/2026 10:25:35 AM A3 ENLARGE PLUMBING GROUP - COMMUNITY C-02 1/4" = 1'-0" PLAN NORTH 0' 2' 4' 8' 1 1 2 2 33 33 4 44 4 4 4 4 4 5 5 52026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) A B C D 1 2 3 4 5 All concepts, designs and plans directly or indirectly encompassed by this document are hereby copyrighted, and are for use on and in connection with the project specified in this document. None of such concepts, designs or plans shall be used by or disclosed to any person, firm or corporation without the prior written permission of Barbara Felix Architecture + Design, LLC. MARK DATE DESCRIPTION FILE NAME PROJECT NO. DRAWN BY CHECKED BY S h e e t N a m e I S S U E D OFSHEET NO. SHEETS CITY OF SANTA FE MICRO-COMMUNITY 2395 RICHARDS AVE. SANTA FE, NM 87507 S h e e t N o. 2 5 1 0 4 TESTUDO ENGINEERING P-501 DETAILS PLUMBING 25001 EJP 25104_P-501 10/21/2026 10:26:03 AM D EXPANSION TANK, PART OF WH-1 SCALE: NONE ASME TEMPERATURE AND PRESSURE RELIEF VALVE WITH DRAIN LINE FULL SIZE OF VALVE TO FLOOR SINK OR OUTSIDE DAYLIGHT DRAIN INTO MOP BASIN BELOW THERMOMETER 0-200°F RANGE SEE PLANS FOR SIZES SEE ELARGED PLAN FOR CONTINUATION WATER HEATER 4" VARIES FINISHED GRADE COMPACTED EARTH CAST IRON STACK SEE PLANS FOR SIZE SCALE: NONE NOTE: THIS DETAIL SIMILAR FOR ONE-WAY CLEAN-OUT TO GRADE. SECTION CAST IRON BEND WYE BRANCH SAME MATERIAL AS LINE NO. 4 REBAR 1-1/2" MINIMUM BRAZE CHAMFER EDGES CAST IRON SOIL PIPE RISER FINISH GRADE FLOW CHAMFER EDGE 90% COMPACTION PLAN SCALE: NONE SEAL ANNULAR SPACE WITH FIRE RATED MATERIALS, THUS, STEEL PIPING-DOW CORNING "FIRE-STOP" RTV FOAM "MODEL 2001"; PLASTIC OR GLASS-DOW CORNING "FIRE-STOP" WRAP STRAP "MODEL 2002" CONCEALED PIPING. 24" X 24" CONCRETE COLLAR WITH #4 RE-BAR 6" THICK IRON FERRULE W/ METAL COUNTER-SUNK SCREW PLUG. 2'-0"x 2'-0"x7" CONCRETE COLLAR WITH #4 REINFORCING EACH WAY IRON FERRULE W/ METAL COUNTER-SUNK SCREW PLUG. GROUT PLUG WHEN C.O. OCCURS AT END OF LINE NOTE: COLLAR TO BE FLUSH WITH PAVING AND SIDEWALKS. SEE PLUMBING EQUIPMENT SCHEDULE FOR DESCRIPTION. SCALE: NONE D D WATER HEATER ASME TEMPERATURE & PRESSURE RELIEF VALVE WITH DRAIN LINE FULL SIZE OF VALVE, SEE PLANS FOR ROUTING OF DRAIN LINE. INSTALL WATER HEATER ON 1-1/2" x 1-1/2" x 1/4" ANGLE IRON FRAME, ALL WELDED CONSTRUCTION TERMINATE DRAIN LINES INTO MOP BASIN LOCATED BELOW VIA INDIRECT DISCHARGE, ROUTE PIPE TIGHT TO WALL. SOLDER 1/2" DRAIN LINE TO BOTTOM OF SHEET METAL PAN 1-1/4" x 1-1/4" x 1/4" ANGLE IRON CROSS-BRACING BELOW WATER HEATER PAN SECURED TO ANGLE IRON FRAME 1-1/4" x 1-1/4" x 1/4" LENGTH AS REQUIRED, ANGLE IRON (TYP.)2026- 013291case #CONDITIONAL USE APPROVAL - PROGRESS SET (NOT FOR CONSTRUCTION) Form Updated: April 2024 Development Review Team (DRT) Comment Form DRT Review Schedule – 9-12+ weeks* Initial DRT Comments are due to the case planner within three weeks of the DRT Application Intake meeting. Initial DRT review should confirm that the application is complete (i.e. Water Budget has been submitted) and/or identify additional submittals or corrections (i.e. Water Budget needs revision). The case planner will review and convey all Initial DRT Comments to the applicant via a Review Memo. The applicant must respond to all Initial DRT Comments and submit a revised application for Final Review. Final DRT Comments are due to the case planner within two weeks of receipt of the revised application. The case planner will review and convey all Final DRT Comments to the applicant in a Final Review Memo. The complete DRT Review Timeline can range from 9-12+ weeks, depending on the complexity and quality of the application and the total number of applications under review. Timing of Conditions of Approval + Technical Corrections While all DRT conditions of approval and technical corrections must be met by the applicant, the timing of compliance varies. In the “Must be completed by” column in the following tables, please time your conditions of approval and technical corrections to the following development review stages: a. Prior to Public Hearing – these conditions/technical corrections must be addressed before the case may move forward to the public hearing phase of the Development Review Process. b. Prior to Recordation – these conditions/technical corrections may be resolved after the public hearing but must be addressed before the Development Plan or Subdivision plat is recorded. c. Prior to Building Permit Approval – these conditions/technical corrections can be addressed during the building permit review process, but prior to issuance of the permit. d. During Construction – these conditions/technical corrections can be addressed during construction. Development Review Process Flow Chart *See the 2024 Development Review Schedule for details DRT Review Timeline: Application Received DRT Application Intake DRT Initial Review Comments Due Initial DRT Comments Review Memo Revised Application Final DRT Comments Final Review MemoEXHIBIT BLAND USE - TECHNICAL REVIEW Form Updated: April 2024 Date: 10/7/2026 DRT Member: Teddy Padilla Dept/Div: Land Use/Technical Review Case No.: 2026-11006 Case Planner: Joel Cruz-Haber Conditions of Approval and Technical Corrections Tables Review by this division/department has determined that this application will meet applicable standards if the following Conditions of Approval and Technical Corrections are met: Case # Conditions of Approval: Must be completed by: Applicant response**: 1. 2. 3. 4. 5. 6. Technical Corrections: Must be completed by: Applicant response**: 1. The Accessible Route must continue to the Security area, to the smoking area, and to the storage area. Prior to Building Permit 2. The Accessible Route must continue to the Security area, to the smoking area, and to the storage area. Prior to Building Permit 3. Bus Stop must comply with COSF 12-6-9.1 Time of Construction 4. The Contractor shall ensure ADA compliance for construction of ADA accessible features and appurtenances, as detailed in, and in addition to, the approved construction permit documents as required. Improvements shall comply with ICC ANSI A117.1-2009 Chapters 1-5 and Chapter 7, 2015 New Mexico Accessible Parking Checklist, MUTCD, NMDOT Pedestrian Access Standards and PROWAG, NM State Statute and Administrative Code and DOJ regulations as applicable. Time of Construction **The Applicant must respond to the condition of approval or technical correction, indicating they have met the requirement and providing a reference in their revised submittals. If the applicant has not met the requirement, they must indicate as much and provide a response. The applicant should be aware that the following code provisions or other requirements will apply to future phases of development of this project: 1. [list any additional items] 2. Explanation of Conditions or Corrections (if needed): (see following pages for notes required)Complies, see attached plansComplies, see attached plansCondition acceptedCondition acceptedCondition acceptedLAND USE - TECHNICAL REVIEW Form Updated: April 2024 Development Review Team (DRT) Comment Form DRT Review Schedule – 9-12+ weeks* Initial DRT Comments are due to the case planner within three weeks of the DRT Application Intake meeting. Initial DRT review should confirm that the application is complete (i.e. Water Budget has been submitted) and/or identify additional submittals or corrections (i.e. Water Budget needs revision). The case planner will review and convey all Initial DRT Comments to the applicant via a Review Memo. The applicant must respond to all Initial DRT Comments and submit a revised application for Final Review. Final DRT Comments are due to the case planner within two weeks of receipt of the revised application. The case planner will review and convey all Final DRT Comments to the applicant in a Final Review Memo. The complete DRT Review Timeline can range from 9-12+ weeks, depending on the complexity and quality of the application and the total number of applications under review. Timing of Conditions of Approval + Technical Corrections While all DRT conditions of approval and technical corrections must be met by the applicant, the timing of compliance varies. In the “Must be completed by” column in the following tables, please time your conditions of approval and technical corrections to the following development review stages: a. Prior to Public Hearing – these conditions/technical corrections must be addressed before the case may move forward to the public hearing phase of the Development Review Process. b. Prior to Recordation – these conditions/technical corrections may be resolved after the public hearing but must be addressed before the Development Plan or Subdivision plat is recorded. c. Prior to Building Permit Approval – these conditions/technical corrections can be addressed during the building permit review process, but prior to issuance of the permit. d. During Construction – these conditions/technical corrections can be addressed during construction. Development Review Process Flow Chart *See the 2024 Development Review Schedule for details DRT Review Timeline: Application Received DRT Application Intake DRT Initial Review Comments Due Monday, October 12, 2026 Initial DRT Comments Review Memo Revised Application Final DRT Comments Final Review MemoLAND USE - HISTORIC PRESERVATION Form Updated: April 2024 Date: October 14, 2026 DRT Member: Lauren A. Vagts, Senior Preservation Planner Dept/Div: Case No.: Land Use and Development - Historic Preservation 2026-013291 – 2395 Richards Avenue, Micro Community Case Planner: Joel Cruz-Haber Conditions of Approval and Technical Corrections Tables Review by this division/department has determined that this application will meet applicable standards if the following Conditions of Approval and Technical Corrections are met: Case # Conditions of Approval: Must be completed by: Applicant response**: 1. If cultural resources or human remains are discovered during the project development, all construction activities must immediately cease and divert to provisions outlined in City Code, 14-2.1(G)(1)(V). as applicable 2. Approval of archaeological monitoring plan by the Archaeological Review Committee submitted by an archaeologist listed on the City of Santa Fe’s List of Approved Archaeologists and Historians. as applicable 3. An archaeological clearance permit is required prior to the final development plan or plat for all City projects over two acres in size, as outlined in the City of Santa Fe Code, 14- 4.2(D)(3)(II) as applicable 4. 5. Technical Corrections: Must be completed by: Applicant response**: 1. 2. 3. 4. **The Applicant must respond to the condition of approval or technical correction, indicating they have met the requirement and providing a reference in their revised submittals. If the applicant has not met the requirement, they must indicate as much and provide a response. The applicant should be aware that the following code provisions or other requirements will apply to future phases of development of this project: While Archaeological Review Committee (ARC) Clearance is not needed at this time, in the case of cultural resources or human remains discovered during project development, the outlined provisions above will need to be enacted and all construction work cease. Explanation of Conditions or Corrections (if needed): n/aN/AN/AN/ALAND USE - TECHNICAL REVIEWNoted and accepted. Form Updated: April 2024 Development Review Team (DRT) Comment Form DRT Review Schedule – 9-12+ weeks* Initial DRT Comments are due to the case planner within three weeks of the DRT Application Intake meeting. Initial DRT review should confirm that the application is complete (i.e. Water Budget has been submitted) and/or identify additional submittals or corrections (i.e. Water Budget needs revision). The case planner will review and convey all Initial DRT Comments to the applicant via a Review Memo. The applicant must respond to all Initial DRT Comments and submit a revised application for Final Review. Final DRT Comments are due to the case planner within two weeks of receipt of the revised application. The case planner will review and convey all Final DRT Comments to the applicant in a Final Review Memo. The complete DRT Review Timeline can range from 9-12+ weeks, depending on the complexity and quality of the application and the total number of applications under review. Timing of Conditions of Approval + Technical Corrections While all DRT conditions of approval and technical corrections must be met by the applicant, the timing of compliance varies. In the “Must be completed by” column in the following tables, please time your conditions of approval and technical corrections to the following development review stages: a. Prior to Public Hearing – these conditions/technical corrections must be addressed before the case may move forward to the public hearing phase of the Development Review Process. b. Prior to Recordation – these conditions/technical corrections may be resolved after the public hearing but must be addressed before the Development Plan or Subdivision plat is recorded. c. Prior to Building Permit Approval – these conditions/technical corrections can be addressed during the building permit review process, but prior to issuance of the permit. d. During Construction – these conditions/technical corrections can be addressed during construction. Development Review Process Flow Chart *See the 2024 Development Review Schedule for details DRT Review Timeline: Application Received DRT Application Intake DRT Initial Review Comments Due Sept 10, 2026 Sept 10, 2026 September 29, 2026 Initial DRT Comments Review Memo Revised Application Final DRT Comments Final Review MemoFIRE DEPARTMENT REVIEW Form Updated: April 2024 Date: October 13, 2026 DRT Member: Dept/Div: Case No.: Geronimo Griego, Fire Marshal Fire Department/ Fire Marshal’s Office 2026-013291. 2395 Richards Ave, Micro CommunityCase Planner: Juel Cruz-Haber, Senior Planner Conditions of Approval and Technical Corrections Tables Review by this division/department has determined that this application will meet applicable standards if the following Conditions of Approval and Technical Corrections are met: Case # Conditions of Approval: Must be completed by: Applicant response**: 1. Shall comply with the most currently adopted International Fire Code (IFC) and adopted city ordinances upon building permit approval. Prior to Public Hearing 2. 3. 4. 5. 6. Technical Corrections: Must be completed by: Applicant response**: 1. 2. 3. 4. **The Applicant must respond to the condition of approval or technical correction, indicating they have met the requirement and providing a reference in their revised submittals. If the applicant has not met the requirement, they must indicate as much and provide a response. The applicant should be aware that the following code provisions or other requirements will apply to future phases of development of this project: 1. [list any additional items] 2. Explanation of Conditions or Corrections (if needed): • Access: Approved as shown on the plans. • Fire Hydrants: Show all existing and proposed hydrants on the plan. Must be within 400 ft of all site areas. • Fire Extinguishers: Add locations to the plan so travel distance is 75 ft maximum from any point on site. • Site Monument Sign: Provide an entrance sign showing: o Site layout & unit numbersComplies, see attached plansSee AS-102.See AS-102.See AS-102; installation prior to construction being complete.FIRE DEPARTMENT REVIEW Form Updated: April 2024 o Emergency contact info o Hydrant & extinguisher locations o Fire access points • Smoke & CO Detectors: Required in all occupied units. CID & Building Classification: Confirm State CID review for City property, and clarify if units are being permitted as temporary or permanent structures.All units come with smoke and CO Detectors; will be confirmed that all work prior to construction being completed.Will review with CID during permitting and report back. Form Updated: April 2024 Date: 10/9/26 DRT Member: Dee Beingessner Dept/Div: Case No.: 2026 - 01329_Micro community Case Planner: Conditions of Approval and Technical Corrections Tables Review by this division/department has determined that this application will meet applicable standards if the following Conditions of Approval and Technical Corrections are met: Case # Conditions of Approval: Must be completed by: Applicant response**: 1. Grading and drainage civil plans along with a drainage report must be submitted and approved prior to permit submittal. Once the civil plans are approved they must be submitted on mylar. Permit Submittal 2. 3. 4. 5. 6. Technical Corrections: Must be completed by: Applicant response**: 1. 2. 3. 4. **The Applicant must respond to the condition of approval or technical correction, indicating they have met the requirement and providing a reference in their revised submittals. If the applicant has not met the requirement, they must indicate as much and provide a response. The applicant should be aware that the following code provisions or other requirements will apply to future phases of development of this project: 1. [list any additional items] 2. Explanation of Conditions or Corrections (if needed): (see following pages for notes required)Condition acceptedLAND USE - GRADING & DRAINAGE Form Updated: April 2024 Development Review Team (DRT) Comment Form DRT Review Schedule – 9-12+ weeks* Initial DRT Comments are due to the case planner within three weeks of the DRT Application Intake meeting. Initial DRT review should confirm that the application is complete (i.e. Water Budget has been submitted) and/or identify additional submittals or corrections (i.e. Water Budget needs revision). The case planner will review and convey all Initial DRT Comments to the applicant via a Review Memo. The applicant must respond to all Initial DRT Comments and submit a revised application for Final Review. Final DRT Comments are due to the case planner within two weeks of receipt of the revised application. The case planner will review and convey all Final DRT Comments to the applicant in a Final Review Memo. The complete DRT Review Timeline can range from 9-12+ weeks, depending on the complexity and quality of the application and the total number of applications under review. Timing of Conditions of Approval + Technical Corrections While all DRT conditions of approval and technical corrections must be met by the applicant, the timing of compliance varies. In the “Must be completed by” column in the following tables, please time your conditions of approval and technical corrections to the following development review stages: a. Prior to Public Hearing – these conditions/technical corrections must be addressed before the case may move forward to the public hearing phase of the Development Review Process. b. Prior to Recordation – these conditions/technical corrections may be resolved after the public hearing but must be addressed before the Development Plan or Subdivision plat is recorded. c. Prior to Building Permit Approval – these conditions/technical corrections can be addressed during the building permit review process, but prior to issuance of the permit. d. During Construction – these conditions/technical corrections can be addressed during construction. Development Review Process Flow Chart *See the 2024 Development Review Schedule for details DRT Review Timeline: Application Received DRT Application Intake DRT Initial Review Comments Due Initial DRT Comments Review Memo Revised Application Final DRT Comments Final Review MemoLANDSCAPE, IRRIGATION, OUTDOOR LIGHTING Form Updated: April 2024 Date: October 13, 2026 DRT Member: Lawrence Rivera Dept/Div: Land Used Landscape, Irrigation, and Outdoor Lighting Review Case No.: 2026-013291. 2395 Richards Ave, Micro Community, Conditional Use Approval. Case Planner: CRUZ-HABER, JOEL A. Conditions of Approval and Technical Corrections Tables Review by this division/department has determined that this application will meet applicable standards if the following Conditions of Approval and Technical Corrections are met: Case # Conditions of Approval: Must be completed by: Applicant response**: 1. 2. 3. 4. 5. 6. Technical Corrections: Must be completed by: Applicant response**: 1. Provide a landscape irrigation plan by a qualified irrigation designer per COSF code Chapter 14-8.4(E) Water Harvesting and Irrigation Standards and COSF Landscape Irrigation Design Standards. Submittal of grading & drainage, and land scape permit. City Staff would consider landscape and irrigation as a phase #2 of the development provided that the irrigation sleeving, mainline, and lateral lines are installed as part of the construct prior to C/O and final approvals of the building permit. Submittal of grading & drainage, and land scape permit. 2. Provide a complete set of installation details, notes, and specifications for the irrigation system. Show on the detail drawings the installation of all assemblies without any questions for size or type of materials to use for said irrigation system. Submittal of grading & drainage, and land scape permit. 3. Provide a water budget: Irrigation system operation information including recommended monthly and seasonal irrigation schedules and water budgets based on gallons used for landscape plantings for year one and year three shall be included on the irrigation plan. Per 3.18. Design Regulations of Landscape Irrigation Design Standards City of Santa Fe, New Mexico. Submittal of grading & drainage, and land scape permit. 4. Landscape design is incomplete, tree and shrub identities are needed, the common and botanical names and varieties as well as the installation plant size are required for this review. Plant water needs as shown on the city approve plant list are also Submittal of grading & drainage, and land scape permit.Condition acceptedCondition acceptedCondition acceptedCondition acceptedCondition acceptedLANDSCAPE, IRRIGATION, OUTDOOR LIGHTING Form Updated: April 2024 required. It is not possible to determine street tree compliance, screening requirements, and plant material variety approval without the plant material identified. 5. Planter beds located at Buildings O-04 IT, S-09, O-03 Office, S-30,S-17, S-24 O-02 Security, and the play area must be defined with a border and Mulched with an approved landscape mulch. Crusher fines are not an approved mulch for plant material. Submittal of grading & drainage, and land scape permit. 6. Pet run must have a double door access. Provide a detail. Provide the name of the dog park surface and I cut sheet. Submittal of grading & drainage, and land scape permit. 7. Provide the play area surface and any proposed play equipment. Details and cut sheets are required. Submittal of grading & drainage, and land scape permit. 8. Provide an outdoor lighting plan with photometric data per 14-8.6 COSF code. Submittal of grading & drainage, and land scape permit. STAFF RESERVES THE RIGHT TO REQUIRE ADDITIONAL SUBMITTALS UPON RECEIVING REVISIONS. **The Applicant must respond to the condition of approval or technical correction, indicating they have met the requirement and providing a reference in their revised submittals. If the applicant has not met the requirement, they must indicate as much and provide a response. The applicant should be aware that the following code provisions or other requirements will apply to future phases of development of this project: 1. [list any additional items] 2. Explanation of Conditions or Corrections (if needed): (see following pages for notes required)Condition acceptedCondition acceptedCondition acceptedPlay Area converted to Common Area. If it becomes a Play Area in the future, this condition will be met.Condition accepted; this will be part of electrical engineering drawings.LANDSCAPE, IRRIGATION, OUTDOOR LIGHTING Form Updated: April 2024 Development Review Team (DRT) Comment Form DRT Review Schedule – 9-12+ weeks* Initial DRT Comments are due to the case planner within three weeks of the DRT Application Intake meeting. Initial DRT review should confirm that the application is complete (i.e. Water Budget has been submitted) and/or identify additional submittals or corrections (i.e. Water Budget needs revision). The case planner will review and convey all Initial DRT Comments to the applicant via a Review Memo. The applicant must respond to all Initial DRT Comments and submit a revised application for Final Review. Final DRT Comments are due to the case planner within two weeks of receipt of the revised application. The case planner will review and convey all Final DRT Comments to the applicant in a Final Review Memo. The complete DRT Review Timeline can range from 9-12+ weeks, depending on the complexity and quality of the application and the total number of applications under review. Timing of Conditions of Approval + Technical Corrections While all DRT conditions of approval and technical corrections must be met by the applicant, the timing of compliance varies. In the “Must be completed by” column in the following tables, please time your conditions of approval and technical corrections to the following development review stages: a. Prior to Public Hearing – these conditions/technical corrections must be addressed before the case may move forward to the public hearing phase of the Development Review Process. b. Prior to Recordation – these conditions/technical corrections may be resolved after the public hearing but must be addressed before the Development Plan or Subdivision plat is recorded. c. Prior to Building Permit Approval – these conditions/technical corrections can be addressed during the building permit review process, but prior to issuance of the permit. d. During Construction – these conditions/technical corrections can be addressed during construction. Development Review Process Flow Chart *See the 2024 Development Review Schedule for details DRT Review Timeline: Application Received DRT Application Intake DRT Initial Review Comments Due October 13, 2026 Initial DRT Comments Review Memo Revised Application Final DRT Comments Final Review MemoPUBLIC WORKS - PARKS & OPEN SPACE Form Updated: April 2024 Date: 10-13-26 DRT Member: Melissa McDonald, Parks and Open Space Division Director Dept/Div: Public Works/ Parks and Open Space Division Director Case No.: Case # 2026-013291. 2395 Richards Ave, Micro Community, Conditional Use Approval. Case Planner: Joel Cruz-Haber, Senior Planner Conditions of Approval and Technical Corrections Tables Review by this division/department has determined that this application will meet applicable standards if the following Conditions of Approval and Technical Corrections are met: Case # Conditions of Approval: Must be completed by: Applicant response**: 1. none 2. 3. 4. 5. 6. Technical Corrections: Must be completed by: Applicant response**: 1. none 2. 3. 4. **The Applicant must respond to the condition of approval or technical correction, indicating they have met the requirement and providing a reference in their revised submittals. If the applicant has not met the requirement, they must indicate as much and provide a response. The applicant should be aware that the following code provisions or other requirements will apply to future phases of development of this project: 1. [list any additional items] 2. Explanation of Conditions or Corrections (if needed): (see following pages for notes required)N/APUBLIC WORKS - PARKS & OPEN SPACE Form Updated: April 2024 Development Review Team (DRT) Comment Form Date: October 13, 2026 DRT Member: Leroy Pacheco, PE Dept/Div: Public Works Department – Traffic Engineering Case No.: #2026-013291 Micro-community Pallet Shelters – 2395 Richards Avenue Case Planner: Joel Cruz-Haber, Senior Planner Conditions of Approval and Technical Corrections Tables Review by this division/department has determined that this application will meet applicable standards if the following Conditions of Approval and Technical Corrections are met: Case # Conditions of Approval: Must be completed by: Applicant response**: 1. None 2. 3. 4. 5. 6. Technical Corrections: Must be completed by: Applicant response**: 1. None 2. 3. 4. **The Applicant must respond to the condition of approval or technical correction, indicating they have met the requirement and providing a reference in their revised submittals. If the applicant has not met the requirement, they must indicate as much and provide a response. The applicant should be aware that the following code provisions or other requirements will apply to future phases of development of this project: 1. City of Santa Fe Building Code, Chapter 23-3.2 states that before commencement of any new construction, it is mandatory for the owner to obtain approval from the Public Works Department for any driveway curb cut or sidewalk crossing. This approval must be issued before a building permit for such new construction is approved. 2. Note as the public infrastructure plans move forward to building permit, these may be subject to additional reviews and possible corrections to meet Public Works Standards for roadways, ADA, signing, striping, lighting, etc. prior to building permit approval.N/APUBLIC WORKS - TRAFFIC ENGINEERINGItems 1 and 2 regarding code provisions are noted. Form Updated: April 2024 Development Review Team (DRT) Comment Form DRT Review Schedule – 9-12+ weeks* Initial DRT Comments are due to the case planner within three weeks of the DRT Application Intake meeting. Initial DRT review should confirm that the application is complete (i.e. Water Budget has been submitted) and/or identify additional submittals or corrections (i.e. Water Budget needs revision). The case planner will review and convey all Initial DRT Comments to the applicant via a Review Memo. The applicant must respond to all Initial DRT Comments and submit a revised application for Final Review. Final DRT Comments are due to the case planner within two weeks of receipt of the revised application. The case planner will review and convey all Final DRT Comments to the applicant in a Final Review Memo. The complete DRT Review Timeline can range from 9-12+ weeks, depending on the complexity and quality of the application and the total number of applications under review. Timing of Conditions of Approval + Technical Corrections While all DRT conditions of approval and technical corrections must be met by the applicant, the timing of compliance varies. In the “Must be completed by” column in the following tables, please time your conditions of approval and technical corrections to the following development review stages: a. Prior to Public Hearing – these conditions/technical corrections must be addressed before the case may move forward to the public hearing phase of the Development Review Process. b. Prior to Recordation – these conditions/technical corrections may be resolved after the public hearing but must be addressed before the Development Plan or Subdivision plat is recorded. c. Prior to Building Permit Approval – these conditions/technical corrections can be addressed during the building permit review process, but prior to issuance of the permit. d. During Construction – these conditions/technical corrections can be addressed during construction. Development Review Process Flow Chart *See the 2024 Development Review Schedule for details DRT Review Timeline: Application Received DRT Application Intake DRT Initial Review Comments Due Initial DRT Comments Review Memo Revised Application Final DRT Comments Final Review MemoPUBLIC UTILITIES - WATER DIVISION Form Updated: April 2024 Date: 10/7/2026 DRT Member: Dept/Div: Case No.: Clinton Peterson Public Utilities / Water Division 2026-013291. 2395 Richards Ave, Micro Community, Conditional Use Approval Case Planner: Joel Cruz-Haber Conditions of Approval and Technical Corrections Tables Review by this division/department has determined that this application will meet applicable standards if the following Conditions of Approval and Technical Corrections are met: Case # 2026-11006 Conditions of Approval: Must be completed by: Applicant response**: 1. IF CoSFW determines that site utility improvements for public water necessitate an Agreement for Metered Service (AMS), an approved AMS will be required for all new domestic or irrigation meters. Prior to Building Permit Approval 2. IF CoSFW determines that site utility improvements for public water necessitate an ACD and Water Plan, an approved Water Plan will be required for all new public water infrastructure and fire services. Water Plan shall be submitted to the City Water Division for review. Prior to Building Permit Approval 3. IF CoSFW determines that site utility improvements for public water necessitate an ACD and Water Plan, an approved Agreement to Construct and Dedicate (ACD) will be required with the Water Division for all new public water infrastructure and fire services. Prior to Building Permit Approval 4. A separate irrigation meter will be required if the total landscaped area is 1,000 square feet or greater. An approved backflow prevention device shall be installed beyond the meter on any new irrigation service. At the time of development 5. Any re-grading of site over existing water mains shall maintain a minimum of 4 feet of cover and not exceed 5 feet of cover. Depth of existing main to be adjusted to maintain a minimum of 4 feet of cover and not exceed 5 feet of cover if site grading impacts these depth requirements. At the time of development 6. Technical Corrections: Must be completed by: Applicant response**: 1. Sizing of site master meter may require an ACD/water plan OR an AMS. Applicant shall work with CoSFW to determine which route is appropriate to provide water utility to this site. n/aCondition acceptedNot ApplicableNot ApplicableCondition acceptedCondition acceptedCondition acceptedPUBLIC UTILITIES - WATER DIVISION Form Updated: April 2024 **The Applicant must respond to the condition of approval or technical correction, indicating they have met the requirement and providing a reference in their revised submittals. If the applicant has not met the requirement, they must indicate as much and provide a response. The applicant should be aware that the following code provisions or other requirements will apply to future phases of development of this project: 1. [list any additional items] 2. Explanation of Conditions or Corrections (if needed): (see following pages for notes required)PUBLIC UTILITIES - WATER DIVISION “Providing housing, homeless services and community programs since 1987” 2000 St Michael Drive, Santa Fe, New Mexico 87505 Office: (505) 438-0010, Fax (505) 438-6011 www.TheLifeLink.org October 20th, 2026 To Whom It May Concern, The Richards Ave Micro Community will provide supportive services Monday through Friday, approximately from 7:00 AM to 6:00 PM. On-site security personnel will be present to assist residents from 6:00 PM to 7:00 AM, Monday through Friday, as well as 24 hours a day on weekends. The Life Link will offer case management, housing assistance, and mental health and substance use services. Additionally, we maintain collaborative partnerships to support youth (under 18) and seniors (over 62). Please note that this prospective schedule is flexible and will adapt to resident needs once operations begin. Our weekly routine will also feature catered meal deliveries 3–4 times per week. Furthermore, The Life Link maintenance staff will be on site for approximately 20 hours per week or as needed. Respectfully, Nicholas Tharpe, CPSW, Site Coordinator Arroyo Chamiso Micro Community The Life Link 1699 Arroyo Chamiso Santa Fe NM 87505 (o)505-395-9703 (c)505-469-1067